Cargando…

Determination of Paracetamol on Electrochemically Reduced Graphene Oxide–Antimony Nanocomposite Modified Pencil Graphite Electrode Using Adsorptive Stripping Differential Pulse Voltammetry

A simple, highly sensitive, accurate, and low-cost electrochemical sensor was developed for the determination of over-the-counter painkiller, paracetamol (PC). The enhanced sensing capabilities of the developed sensor were fabricated by the single-step modification of disposable pencil graphite elec...

Descripción completa

Detalles Bibliográficos
Autores principales: Leve, Zandile D., Jahed, Nazeem, Sanga, Nelia A., Iwuoha, Emmanuel I., Pokpas, Keagan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9370859/
https://www.ncbi.nlm.nih.gov/pubmed/35957341
http://dx.doi.org/10.3390/s22155784
_version_ 1784766943741345792
author Leve, Zandile D.
Jahed, Nazeem
Sanga, Nelia A.
Iwuoha, Emmanuel I.
Pokpas, Keagan
author_facet Leve, Zandile D.
Jahed, Nazeem
Sanga, Nelia A.
Iwuoha, Emmanuel I.
Pokpas, Keagan
author_sort Leve, Zandile D.
collection PubMed
description A simple, highly sensitive, accurate, and low-cost electrochemical sensor was developed for the determination of over-the-counter painkiller, paracetamol (PC). The enhanced sensing capabilities of the developed sensor were fabricated by the single-step modification of disposable pencil graphite electrodes (PGEs) with the simultaneous electrochemical reduction in graphene oxide and antimony (II) salts. For this purpose, an electrochemically reduced graphene oxide–antimony nanoparticle (ERGO-SbNP) nanocomposite material was prepared by trapping metallic nanoparticles between individual graphene sheets in the modification of PGEs. Structural characterization by FTIR and Raman spectroscopy was employed to confirm the presence of oxygen functional groups and defects in the conjugated carbon-based structure of GO. Morphological differences between the modified PGEs were confirmed by HRTEM and HRSEM for the presence of nanoparticles. The modified electrodes were further electrochemically characterized using CV and EIS. The electrooxidation of PC on an ERGO-SbNPs-PGE was achieved by adsorptive stripping differential pulse voltametric analysis in 0.1 mol·L(−1) phosphate buffer solution at pH = 7.0. The optimum current response was used to record a detection limit of 0.057 µmol·L(−1) for PC. The electrochemical sensor was further used in real sample analysis for a commercially available pharmaceutical tablet (500 mg PC), for which the percentage recovery was between 99.4% and 100.8%.
format Online
Article
Text
id pubmed-9370859
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-93708592022-08-12 Determination of Paracetamol on Electrochemically Reduced Graphene Oxide–Antimony Nanocomposite Modified Pencil Graphite Electrode Using Adsorptive Stripping Differential Pulse Voltammetry Leve, Zandile D. Jahed, Nazeem Sanga, Nelia A. Iwuoha, Emmanuel I. Pokpas, Keagan Sensors (Basel) Article A simple, highly sensitive, accurate, and low-cost electrochemical sensor was developed for the determination of over-the-counter painkiller, paracetamol (PC). The enhanced sensing capabilities of the developed sensor were fabricated by the single-step modification of disposable pencil graphite electrodes (PGEs) with the simultaneous electrochemical reduction in graphene oxide and antimony (II) salts. For this purpose, an electrochemically reduced graphene oxide–antimony nanoparticle (ERGO-SbNP) nanocomposite material was prepared by trapping metallic nanoparticles between individual graphene sheets in the modification of PGEs. Structural characterization by FTIR and Raman spectroscopy was employed to confirm the presence of oxygen functional groups and defects in the conjugated carbon-based structure of GO. Morphological differences between the modified PGEs were confirmed by HRTEM and HRSEM for the presence of nanoparticles. The modified electrodes were further electrochemically characterized using CV and EIS. The electrooxidation of PC on an ERGO-SbNPs-PGE was achieved by adsorptive stripping differential pulse voltametric analysis in 0.1 mol·L(−1) phosphate buffer solution at pH = 7.0. The optimum current response was used to record a detection limit of 0.057 µmol·L(−1) for PC. The electrochemical sensor was further used in real sample analysis for a commercially available pharmaceutical tablet (500 mg PC), for which the percentage recovery was between 99.4% and 100.8%. MDPI 2022-08-03 /pmc/articles/PMC9370859/ /pubmed/35957341 http://dx.doi.org/10.3390/s22155784 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Leve, Zandile D.
Jahed, Nazeem
Sanga, Nelia A.
Iwuoha, Emmanuel I.
Pokpas, Keagan
Determination of Paracetamol on Electrochemically Reduced Graphene Oxide–Antimony Nanocomposite Modified Pencil Graphite Electrode Using Adsorptive Stripping Differential Pulse Voltammetry
title Determination of Paracetamol on Electrochemically Reduced Graphene Oxide–Antimony Nanocomposite Modified Pencil Graphite Electrode Using Adsorptive Stripping Differential Pulse Voltammetry
title_full Determination of Paracetamol on Electrochemically Reduced Graphene Oxide–Antimony Nanocomposite Modified Pencil Graphite Electrode Using Adsorptive Stripping Differential Pulse Voltammetry
title_fullStr Determination of Paracetamol on Electrochemically Reduced Graphene Oxide–Antimony Nanocomposite Modified Pencil Graphite Electrode Using Adsorptive Stripping Differential Pulse Voltammetry
title_full_unstemmed Determination of Paracetamol on Electrochemically Reduced Graphene Oxide–Antimony Nanocomposite Modified Pencil Graphite Electrode Using Adsorptive Stripping Differential Pulse Voltammetry
title_short Determination of Paracetamol on Electrochemically Reduced Graphene Oxide–Antimony Nanocomposite Modified Pencil Graphite Electrode Using Adsorptive Stripping Differential Pulse Voltammetry
title_sort determination of paracetamol on electrochemically reduced graphene oxide–antimony nanocomposite modified pencil graphite electrode using adsorptive stripping differential pulse voltammetry
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9370859/
https://www.ncbi.nlm.nih.gov/pubmed/35957341
http://dx.doi.org/10.3390/s22155784
work_keys_str_mv AT levezandiled determinationofparacetamolonelectrochemicallyreducedgrapheneoxideantimonynanocompositemodifiedpencilgraphiteelectrodeusingadsorptivestrippingdifferentialpulsevoltammetry
AT jahednazeem determinationofparacetamolonelectrochemicallyreducedgrapheneoxideantimonynanocompositemodifiedpencilgraphiteelectrodeusingadsorptivestrippingdifferentialpulsevoltammetry
AT sanganeliaa determinationofparacetamolonelectrochemicallyreducedgrapheneoxideantimonynanocompositemodifiedpencilgraphiteelectrodeusingadsorptivestrippingdifferentialpulsevoltammetry
AT iwuohaemmanueli determinationofparacetamolonelectrochemicallyreducedgrapheneoxideantimonynanocompositemodifiedpencilgraphiteelectrodeusingadsorptivestrippingdifferentialpulsevoltammetry
AT pokpaskeagan determinationofparacetamolonelectrochemicallyreducedgrapheneoxideantimonynanocompositemodifiedpencilgraphiteelectrodeusingadsorptivestrippingdifferentialpulsevoltammetry