Design Validation of a Low-Cost EMG Sensor Compared to a Commercial-Based System for Measuring Muscle Activity and Fatigue
Electromyography (EMG) sensors have been used for measuring muscle signals and for diagnosing neuromuscular disease. Available commercial EMG sensor are expensive and not easily available for individuals. The aim of the study is to validate our designed low-cost sensor against a well-known commercia...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9370927/ https://www.ncbi.nlm.nih.gov/pubmed/35957354 http://dx.doi.org/10.3390/s22155799 |
Sumario: | Electromyography (EMG) sensors have been used for measuring muscle signals and for diagnosing neuromuscular disease. Available commercial EMG sensor are expensive and not easily available for individuals. The aim of the study is to validate our designed low-cost sensor against a well-known commercial system for measuring muscle activity and fatigue assessment. The evaluation of the designed system was done through a series of dynamic exercises performed by volunteers. Our low-cost EMG sensor and the commercially available system were placed on the vastus lateralis muscle to concurrently record the signal in a maximum voluntary contraction (MVC). The signal analysis was done using two validation indicators: Spearman’s correlation, and intra-class cross correlation on SPSS 26.0 version. For the muscle fatigue assessment, the root mean square (RMS), mean absolute value (MAV) and mean frequency (MNF) indicators were used. The results at the peak and mean level muscle contraction intensity were computed. The relative agreement for the two systems was excellent at peak level muscle contraction range (ICC 0.74–0.92), average 0.83 and mean level muscle contraction intensity range (ICC 0.65–0.85) with an average of 0.74. The Spearman’s correlation average was 0.76 with the range of (0.71–0.85) at peak level contraction, whiles the mean level contraction average was 0.71 at a range of (0.62–0.81). In determining muscle fatigue, the RMS and MAV showed increasing values in the time domain, while the MEF decreased in the frequency domain. Overall, the results indicated a good to excellent agreement of the two systems and confirmed the reliability of our design. The low-cost sensor also proved to be suitable for muscle fatigue assessment. Our designed system can therefore be implemented for rehabilitation, sports science, and ergonomics. |
---|