Cargando…

Evaluation of the Foot Center of Pressure Estimation from Pressure Insoles during Sidestep Cuts, Runs and Walks

Estimating the foot center of pressure (CoP) position by pressure insoles appears to be an interesting technical solution to perform motion analysis beyond the force platforms surface area. The aim of this study was to estimate the CoP position from Moticon [Formula: see text] pressure insoles durin...

Descripción completa

Detalles Bibliográficos
Autores principales: Morin, Pauline, Muller, Antoine, Pontonnier, Charles, Dumont, Georges
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9370979/
https://www.ncbi.nlm.nih.gov/pubmed/35957186
http://dx.doi.org/10.3390/s22155628
_version_ 1784766988269125632
author Morin, Pauline
Muller, Antoine
Pontonnier, Charles
Dumont, Georges
author_facet Morin, Pauline
Muller, Antoine
Pontonnier, Charles
Dumont, Georges
author_sort Morin, Pauline
collection PubMed
description Estimating the foot center of pressure (CoP) position by pressure insoles appears to be an interesting technical solution to perform motion analysis beyond the force platforms surface area. The aim of this study was to estimate the CoP position from Moticon [Formula: see text] pressure insoles during sidestep cuts, runs and walks. The CoP positions assessed from force platform data and from pressure insole data were compared. One calibration trial performed on the force platforms was used to localize the insoles in the reference coordinate system. The most accurate results were obtained when the motion performed during the calibration trial was similar to the motion under study. In such a case, mean accuracy of CoP position have been evaluated to [Formula: see text] mm along anteroposterior (AP) axis and [Formula: see text] mm along mediolateral (ML) axis for sidestep cuts, [Formula: see text] mm along AP axis and [Formula: see text] mm along ML axis for runs, [Formula: see text] mm along AP axis and [Formula: see text] mm along ML axis for walks. The accuracy of the CoP position assesment from pressure insole data increased with the vertical force applied to the pressure insole and with the number of pressure cells involved.
format Online
Article
Text
id pubmed-9370979
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-93709792022-08-12 Evaluation of the Foot Center of Pressure Estimation from Pressure Insoles during Sidestep Cuts, Runs and Walks Morin, Pauline Muller, Antoine Pontonnier, Charles Dumont, Georges Sensors (Basel) Communication Estimating the foot center of pressure (CoP) position by pressure insoles appears to be an interesting technical solution to perform motion analysis beyond the force platforms surface area. The aim of this study was to estimate the CoP position from Moticon [Formula: see text] pressure insoles during sidestep cuts, runs and walks. The CoP positions assessed from force platform data and from pressure insole data were compared. One calibration trial performed on the force platforms was used to localize the insoles in the reference coordinate system. The most accurate results were obtained when the motion performed during the calibration trial was similar to the motion under study. In such a case, mean accuracy of CoP position have been evaluated to [Formula: see text] mm along anteroposterior (AP) axis and [Formula: see text] mm along mediolateral (ML) axis for sidestep cuts, [Formula: see text] mm along AP axis and [Formula: see text] mm along ML axis for runs, [Formula: see text] mm along AP axis and [Formula: see text] mm along ML axis for walks. The accuracy of the CoP position assesment from pressure insole data increased with the vertical force applied to the pressure insole and with the number of pressure cells involved. MDPI 2022-07-27 /pmc/articles/PMC9370979/ /pubmed/35957186 http://dx.doi.org/10.3390/s22155628 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Communication
Morin, Pauline
Muller, Antoine
Pontonnier, Charles
Dumont, Georges
Evaluation of the Foot Center of Pressure Estimation from Pressure Insoles during Sidestep Cuts, Runs and Walks
title Evaluation of the Foot Center of Pressure Estimation from Pressure Insoles during Sidestep Cuts, Runs and Walks
title_full Evaluation of the Foot Center of Pressure Estimation from Pressure Insoles during Sidestep Cuts, Runs and Walks
title_fullStr Evaluation of the Foot Center of Pressure Estimation from Pressure Insoles during Sidestep Cuts, Runs and Walks
title_full_unstemmed Evaluation of the Foot Center of Pressure Estimation from Pressure Insoles during Sidestep Cuts, Runs and Walks
title_short Evaluation of the Foot Center of Pressure Estimation from Pressure Insoles during Sidestep Cuts, Runs and Walks
title_sort evaluation of the foot center of pressure estimation from pressure insoles during sidestep cuts, runs and walks
topic Communication
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9370979/
https://www.ncbi.nlm.nih.gov/pubmed/35957186
http://dx.doi.org/10.3390/s22155628
work_keys_str_mv AT morinpauline evaluationofthefootcenterofpressureestimationfrompressureinsolesduringsidestepcutsrunsandwalks
AT mullerantoine evaluationofthefootcenterofpressureestimationfrompressureinsolesduringsidestepcutsrunsandwalks
AT pontonniercharles evaluationofthefootcenterofpressureestimationfrompressureinsolesduringsidestepcutsrunsandwalks
AT dumontgeorges evaluationofthefootcenterofpressureestimationfrompressureinsolesduringsidestepcutsrunsandwalks