Cargando…

Equivalent Calibration Method Based on a Blackbody Baffle Substitution for a Large External Surface-Source Blackbody

Highly accurate measurements of infrared systems cannot be achieved without precise radiometric calibrations. In order to correctly interpret and process infrared images and monitor the performance of infrared cameras, their radiometric calibration is also required periodically. In this paper, an eq...

Descripción completa

Detalles Bibliográficos
Autores principales: Pang, Xinyu, Yu, Yi, Li, Zhou, Sun, Zhiyuan, Li, Chun, Yang, Guoqing
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9371206/
https://www.ncbi.nlm.nih.gov/pubmed/35957402
http://dx.doi.org/10.3390/s22155844
_version_ 1784767066404814848
author Pang, Xinyu
Yu, Yi
Li, Zhou
Sun, Zhiyuan
Li, Chun
Yang, Guoqing
author_facet Pang, Xinyu
Yu, Yi
Li, Zhou
Sun, Zhiyuan
Li, Chun
Yang, Guoqing
author_sort Pang, Xinyu
collection PubMed
description Highly accurate measurements of infrared systems cannot be achieved without precise radiometric calibrations. In order to correctly interpret and process infrared images and monitor the performance of infrared cameras, their radiometric calibration is also required periodically. In this paper, an equivalent calibration method is proposed based on an internal blackbody baffle. It is used for the replacement of a large surface-source blackbody covering the aperture for the field calibration of large-aperture equipment. Subsequently, the expressions of the equivalent calibration conversion function (ECCF) are derived based on the grayscale response of the camera and the calibration models of the two methods, and experimental measurements and fits are performed using a cooled mid-wave infrared camera. The results show that the measured functional form is consistent with the physical meaning. Moreover, in the target imaging experiments, the results of the inversion using the equivalent calibration conversion function and the results of the direct calibration of the external blackbody are largely consistent with the average error of 0.198% between the two, and the maximum error is within 1%. The maximum error between the inversion result of radiation brightness and the actual value of the target is 6.29%, and the accuracy fully meets the radiometric measurement requirements.
format Online
Article
Text
id pubmed-9371206
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-93712062022-08-12 Equivalent Calibration Method Based on a Blackbody Baffle Substitution for a Large External Surface-Source Blackbody Pang, Xinyu Yu, Yi Li, Zhou Sun, Zhiyuan Li, Chun Yang, Guoqing Sensors (Basel) Article Highly accurate measurements of infrared systems cannot be achieved without precise radiometric calibrations. In order to correctly interpret and process infrared images and monitor the performance of infrared cameras, their radiometric calibration is also required periodically. In this paper, an equivalent calibration method is proposed based on an internal blackbody baffle. It is used for the replacement of a large surface-source blackbody covering the aperture for the field calibration of large-aperture equipment. Subsequently, the expressions of the equivalent calibration conversion function (ECCF) are derived based on the grayscale response of the camera and the calibration models of the two methods, and experimental measurements and fits are performed using a cooled mid-wave infrared camera. The results show that the measured functional form is consistent with the physical meaning. Moreover, in the target imaging experiments, the results of the inversion using the equivalent calibration conversion function and the results of the direct calibration of the external blackbody are largely consistent with the average error of 0.198% between the two, and the maximum error is within 1%. The maximum error between the inversion result of radiation brightness and the actual value of the target is 6.29%, and the accuracy fully meets the radiometric measurement requirements. MDPI 2022-08-04 /pmc/articles/PMC9371206/ /pubmed/35957402 http://dx.doi.org/10.3390/s22155844 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Pang, Xinyu
Yu, Yi
Li, Zhou
Sun, Zhiyuan
Li, Chun
Yang, Guoqing
Equivalent Calibration Method Based on a Blackbody Baffle Substitution for a Large External Surface-Source Blackbody
title Equivalent Calibration Method Based on a Blackbody Baffle Substitution for a Large External Surface-Source Blackbody
title_full Equivalent Calibration Method Based on a Blackbody Baffle Substitution for a Large External Surface-Source Blackbody
title_fullStr Equivalent Calibration Method Based on a Blackbody Baffle Substitution for a Large External Surface-Source Blackbody
title_full_unstemmed Equivalent Calibration Method Based on a Blackbody Baffle Substitution for a Large External Surface-Source Blackbody
title_short Equivalent Calibration Method Based on a Blackbody Baffle Substitution for a Large External Surface-Source Blackbody
title_sort equivalent calibration method based on a blackbody baffle substitution for a large external surface-source blackbody
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9371206/
https://www.ncbi.nlm.nih.gov/pubmed/35957402
http://dx.doi.org/10.3390/s22155844
work_keys_str_mv AT pangxinyu equivalentcalibrationmethodbasedonablackbodybafflesubstitutionforalargeexternalsurfacesourceblackbody
AT yuyi equivalentcalibrationmethodbasedonablackbodybafflesubstitutionforalargeexternalsurfacesourceblackbody
AT lizhou equivalentcalibrationmethodbasedonablackbodybafflesubstitutionforalargeexternalsurfacesourceblackbody
AT sunzhiyuan equivalentcalibrationmethodbasedonablackbodybafflesubstitutionforalargeexternalsurfacesourceblackbody
AT lichun equivalentcalibrationmethodbasedonablackbodybafflesubstitutionforalargeexternalsurfacesourceblackbody
AT yangguoqing equivalentcalibrationmethodbasedonablackbodybafflesubstitutionforalargeexternalsurfacesourceblackbody