Development of a High-Linearity Voltage and Current Probe with a Floating Toroidal Coil: Principle, Demonstration, Design Optimization, and Evaluation

As the conventional voltage and current (VI) probes widely used in plasma diagnostics have separate voltage and current sensors, crosstalk between the sensors leads to degradation of measurement linearity, which is related to practical accuracy. Here, we propose a VI probe with a floating toroidal c...

Descripción completa

Detalles Bibliográficos
Autores principales: Kim, Si-jun, Seong, In-ho, Lee, Young-seok, Cho, Chul-hee, Jeong, Won-nyoung, You, Ye-bin, Lee, Jang-jae, You, Shin-jae
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9371410/
https://www.ncbi.nlm.nih.gov/pubmed/35957427
http://dx.doi.org/10.3390/s22155871