Cargando…
Protocol and reference values for minimal detectable change of MyotonPRO and ultrasound imaging measurements of muscle and subcutaneous tissue
The assessment of muscle health is of paramount importance, as the loss of muscle mass and strength can affect performance. Two non-invasive tools that have been found to be useful in this are the MyotonPRO and rehabilitative ultrasound imaging, both have shown to be reliable in previous studies man...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Nature Publishing Group UK
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9372175/ https://www.ncbi.nlm.nih.gov/pubmed/35953503 http://dx.doi.org/10.1038/s41598-022-17507-2 |
_version_ | 1784767323080491008 |
---|---|
author | Muckelt, Paul E. Warner, Martin B. Cheliotis-James, Tom Muckelt, Rachel Hastermann, Maria Schoenrock, Britt Martin, David MacGregor, Robert Blottner, Dieter Stokes, Maria |
author_facet | Muckelt, Paul E. Warner, Martin B. Cheliotis-James, Tom Muckelt, Rachel Hastermann, Maria Schoenrock, Britt Martin, David MacGregor, Robert Blottner, Dieter Stokes, Maria |
author_sort | Muckelt, Paul E. |
collection | PubMed |
description | The assessment of muscle health is of paramount importance, as the loss of muscle mass and strength can affect performance. Two non-invasive tools that have been found to be useful in this are the MyotonPRO and rehabilitative ultrasound imaging, both have shown to be reliable in previous studies many of which conducted by the research team. This study aims to determine the reliability of previously unassessed local body structures and to determine their minimal detectable changes (MDC) to support both researchers and clinicians. Twenty healthy participants were recruited to determine the reliability of seven skin positions out of a previously established protocol. Reliability was determined between three independent raters, and day to day reliability was assessed with one rater a week apart. Intraclass Correlation Coefficients (ICC) between raters and between days for tissue stiffness, tone and elasticity range from moderate to excellent (ICC 0.52–0.97), with most good or excellent. ICCs for subcutaneous thickness between days was good or excellent (ICC 0.86–0.91) and moderate to excellent between raters (ICC 0.72–0.96), in muscles it was moderate to excellent between raters and days (ICC 0.71–0.95). The protocol in this study is repeatable with overall good reliability, it also provides established MDC values for several measurement points. |
format | Online Article Text |
id | pubmed-9372175 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Nature Publishing Group UK |
record_format | MEDLINE/PubMed |
spelling | pubmed-93721752022-08-13 Protocol and reference values for minimal detectable change of MyotonPRO and ultrasound imaging measurements of muscle and subcutaneous tissue Muckelt, Paul E. Warner, Martin B. Cheliotis-James, Tom Muckelt, Rachel Hastermann, Maria Schoenrock, Britt Martin, David MacGregor, Robert Blottner, Dieter Stokes, Maria Sci Rep Article The assessment of muscle health is of paramount importance, as the loss of muscle mass and strength can affect performance. Two non-invasive tools that have been found to be useful in this are the MyotonPRO and rehabilitative ultrasound imaging, both have shown to be reliable in previous studies many of which conducted by the research team. This study aims to determine the reliability of previously unassessed local body structures and to determine their minimal detectable changes (MDC) to support both researchers and clinicians. Twenty healthy participants were recruited to determine the reliability of seven skin positions out of a previously established protocol. Reliability was determined between three independent raters, and day to day reliability was assessed with one rater a week apart. Intraclass Correlation Coefficients (ICC) between raters and between days for tissue stiffness, tone and elasticity range from moderate to excellent (ICC 0.52–0.97), with most good or excellent. ICCs for subcutaneous thickness between days was good or excellent (ICC 0.86–0.91) and moderate to excellent between raters (ICC 0.72–0.96), in muscles it was moderate to excellent between raters and days (ICC 0.71–0.95). The protocol in this study is repeatable with overall good reliability, it also provides established MDC values for several measurement points. Nature Publishing Group UK 2022-08-11 /pmc/articles/PMC9372175/ /pubmed/35953503 http://dx.doi.org/10.1038/s41598-022-17507-2 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Article Muckelt, Paul E. Warner, Martin B. Cheliotis-James, Tom Muckelt, Rachel Hastermann, Maria Schoenrock, Britt Martin, David MacGregor, Robert Blottner, Dieter Stokes, Maria Protocol and reference values for minimal detectable change of MyotonPRO and ultrasound imaging measurements of muscle and subcutaneous tissue |
title | Protocol and reference values for minimal detectable change of MyotonPRO and ultrasound imaging measurements of muscle and subcutaneous tissue |
title_full | Protocol and reference values for minimal detectable change of MyotonPRO and ultrasound imaging measurements of muscle and subcutaneous tissue |
title_fullStr | Protocol and reference values for minimal detectable change of MyotonPRO and ultrasound imaging measurements of muscle and subcutaneous tissue |
title_full_unstemmed | Protocol and reference values for minimal detectable change of MyotonPRO and ultrasound imaging measurements of muscle and subcutaneous tissue |
title_short | Protocol and reference values for minimal detectable change of MyotonPRO and ultrasound imaging measurements of muscle and subcutaneous tissue |
title_sort | protocol and reference values for minimal detectable change of myotonpro and ultrasound imaging measurements of muscle and subcutaneous tissue |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9372175/ https://www.ncbi.nlm.nih.gov/pubmed/35953503 http://dx.doi.org/10.1038/s41598-022-17507-2 |
work_keys_str_mv | AT muckeltpaule protocolandreferencevaluesforminimaldetectablechangeofmyotonproandultrasoundimagingmeasurementsofmuscleandsubcutaneoustissue AT warnermartinb protocolandreferencevaluesforminimaldetectablechangeofmyotonproandultrasoundimagingmeasurementsofmuscleandsubcutaneoustissue AT cheliotisjamestom protocolandreferencevaluesforminimaldetectablechangeofmyotonproandultrasoundimagingmeasurementsofmuscleandsubcutaneoustissue AT muckeltrachel protocolandreferencevaluesforminimaldetectablechangeofmyotonproandultrasoundimagingmeasurementsofmuscleandsubcutaneoustissue AT hastermannmaria protocolandreferencevaluesforminimaldetectablechangeofmyotonproandultrasoundimagingmeasurementsofmuscleandsubcutaneoustissue AT schoenrockbritt protocolandreferencevaluesforminimaldetectablechangeofmyotonproandultrasoundimagingmeasurementsofmuscleandsubcutaneoustissue AT martindavid protocolandreferencevaluesforminimaldetectablechangeofmyotonproandultrasoundimagingmeasurementsofmuscleandsubcutaneoustissue AT macgregorrobert protocolandreferencevaluesforminimaldetectablechangeofmyotonproandultrasoundimagingmeasurementsofmuscleandsubcutaneoustissue AT blottnerdieter protocolandreferencevaluesforminimaldetectablechangeofmyotonproandultrasoundimagingmeasurementsofmuscleandsubcutaneoustissue AT stokesmaria protocolandreferencevaluesforminimaldetectablechangeofmyotonproandultrasoundimagingmeasurementsofmuscleandsubcutaneoustissue |