Historical development of the anesthetic machine: from Morton to the integration of the mechanical ventilator
The first anesthetic machines appeared following their public demonstration by Morton in 1846. These initial devices were simple inhalers based on the evaporation of the anesthetic agent. Their main problem was the loss of effectiveness with cooling. More complex inhalers were subsequently developed...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9373687/ https://www.ncbi.nlm.nih.gov/pubmed/33894858 http://dx.doi.org/10.1016/j.bjane.2021.02.017 |
_version_ | 1784767649425653760 |
---|---|
author | Romero-Ávila, Pablo Márquez-Espinós, Carlos Cabrera Afonso, Juan R. |
author_facet | Romero-Ávila, Pablo Márquez-Espinós, Carlos Cabrera Afonso, Juan R. |
author_sort | Romero-Ávila, Pablo |
collection | PubMed |
description | The first anesthetic machines appeared following their public demonstration by Morton in 1846. These initial devices were simple inhalers based on the evaporation of the anesthetic agent. Their main problem was the loss of effectiveness with cooling. More complex inhalers were subsequently developed, in which the main difference was the possibility to provide more than one agent. Moreover, the concentration of the inhaled anesthetic was regulated for greater efficiency. At the beginning of the twentieth century, gas machines emerged, allowing the application of an anesthetic flow independent of the patient’s inspiratory effort. These machines incorporated technological advances such as flow meters, carbon dioxide absorption systems and fine adjustment vaporizers. In this period, in the field of thoracic surgery, intraoperative artificial ventilation began to be employed, which helped overcome the problem of pneumothorax associated with open pleura by applying positive pressure. From the 1930s, the gas machines were fitted with a ventilator, and by the 1950s this had become a basic component of the anesthesia system. Later still, in the 1980s, alarm and monitoring systems were incorporated, giving rise to the current generation of workstations. |
format | Online Article Text |
id | pubmed-9373687 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-93736872022-08-15 Historical development of the anesthetic machine: from Morton to the integration of the mechanical ventilator Romero-Ávila, Pablo Márquez-Espinós, Carlos Cabrera Afonso, Juan R. Braz J Anesthesiol Narrative Review The first anesthetic machines appeared following their public demonstration by Morton in 1846. These initial devices were simple inhalers based on the evaporation of the anesthetic agent. Their main problem was the loss of effectiveness with cooling. More complex inhalers were subsequently developed, in which the main difference was the possibility to provide more than one agent. Moreover, the concentration of the inhaled anesthetic was regulated for greater efficiency. At the beginning of the twentieth century, gas machines emerged, allowing the application of an anesthetic flow independent of the patient’s inspiratory effort. These machines incorporated technological advances such as flow meters, carbon dioxide absorption systems and fine adjustment vaporizers. In this period, in the field of thoracic surgery, intraoperative artificial ventilation began to be employed, which helped overcome the problem of pneumothorax associated with open pleura by applying positive pressure. From the 1930s, the gas machines were fitted with a ventilator, and by the 1950s this had become a basic component of the anesthesia system. Later still, in the 1980s, alarm and monitoring systems were incorporated, giving rise to the current generation of workstations. Elsevier 2021-02-10 /pmc/articles/PMC9373687/ /pubmed/33894858 http://dx.doi.org/10.1016/j.bjane.2021.02.017 Text en © 2021 Sociedade Brasileira de Anestesiologia. Published by Elsevier Editora Ltda. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Narrative Review Romero-Ávila, Pablo Márquez-Espinós, Carlos Cabrera Afonso, Juan R. Historical development of the anesthetic machine: from Morton to the integration of the mechanical ventilator |
title | Historical development of the anesthetic machine: from Morton to the integration of the mechanical ventilator |
title_full | Historical development of the anesthetic machine: from Morton to the integration of the mechanical ventilator |
title_fullStr | Historical development of the anesthetic machine: from Morton to the integration of the mechanical ventilator |
title_full_unstemmed | Historical development of the anesthetic machine: from Morton to the integration of the mechanical ventilator |
title_short | Historical development of the anesthetic machine: from Morton to the integration of the mechanical ventilator |
title_sort | historical development of the anesthetic machine: from morton to the integration of the mechanical ventilator |
topic | Narrative Review |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9373687/ https://www.ncbi.nlm.nih.gov/pubmed/33894858 http://dx.doi.org/10.1016/j.bjane.2021.02.017 |
work_keys_str_mv | AT romeroavilapablo historicaldevelopmentoftheanestheticmachinefrommortontotheintegrationofthemechanicalventilator AT marquezespinoscarlos historicaldevelopmentoftheanestheticmachinefrommortontotheintegrationofthemechanicalventilator AT cabreraafonsojuanr historicaldevelopmentoftheanestheticmachinefrommortontotheintegrationofthemechanicalventilator |