Cargando…
Evaluation of indirect sequence-specific magneto-extraction-aided LAMP for fluorescence and electrochemical SARS-CoV-2 nucleic acid detection
Nucleic acid amplification tests (NAATs) such as quantitative real-time reverse transcriptase PCR (qRT-PCR) or isothermal NAATs (iNAATs) such as loop-mediated isothermal amplification (LAMP) require pure nucleic acid free of any polymerase inhibitors as its substrate. This in turn, warrants the use...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier B.V.
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9373715/ https://www.ncbi.nlm.nih.gov/pubmed/35985192 http://dx.doi.org/10.1016/j.talanta.2022.123809 |
_version_ | 1784767655068041216 |
---|---|
author | Tripathy, Sayantan Agarkar, Tanvi Talukdar, Arunansu Sengupta, Mrittika Kumar, Ashvani Ghosh, Souradyuti |
author_facet | Tripathy, Sayantan Agarkar, Tanvi Talukdar, Arunansu Sengupta, Mrittika Kumar, Ashvani Ghosh, Souradyuti |
author_sort | Tripathy, Sayantan |
collection | PubMed |
description | Nucleic acid amplification tests (NAATs) such as quantitative real-time reverse transcriptase PCR (qRT-PCR) or isothermal NAATs (iNAATs) such as loop-mediated isothermal amplification (LAMP) require pure nucleic acid free of any polymerase inhibitors as its substrate. This in turn, warrants the use of spin-column mediated extraction with centralized high-speed centrifuges. Additionally, the utilization of centralized real-time fluorescence readout and TaqMan-like molecular probes in qRT-PCR and real-time LAMP add cost and restrict their deployment. To circumvent these disadvantages, we report a novel sample-to-answer workflow comprising an indirect sequence-specific magneto-extraction (also referred to as magnetocapture, magneto-preconcentration, or magneto-enrichment) for detecting SARS-CoV-2 nucleic acid. It was followed by in situ fluorescence or electrochemical LAMP. After in silico validation of the approach's sequence selectivity against SARS-CoV-2 variants of concern, the comparative performance of indirect and direct magnetocapture in detecting SARS-CoV-2 nucleic acid in the presence of excess host nucleic acid or serum was probed. After proven superior, the sensitivity of the indirect sequence-specific magnetocapture in conjunction with electrochemical LAMP was investigated. In each case, its sensitivity was assessed through the detection of clinically relevant 10(2) and 10(3) copies of target nucleic acid. Overall, a highly specific nucleic acid detection method was established that can be accommodated for either centralized real-time SYBR-based fluorescence LAMP or portable electrochemical LAMP. |
format | Online Article Text |
id | pubmed-9373715 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Elsevier B.V. |
record_format | MEDLINE/PubMed |
spelling | pubmed-93737152022-08-12 Evaluation of indirect sequence-specific magneto-extraction-aided LAMP for fluorescence and electrochemical SARS-CoV-2 nucleic acid detection Tripathy, Sayantan Agarkar, Tanvi Talukdar, Arunansu Sengupta, Mrittika Kumar, Ashvani Ghosh, Souradyuti Talanta Article Nucleic acid amplification tests (NAATs) such as quantitative real-time reverse transcriptase PCR (qRT-PCR) or isothermal NAATs (iNAATs) such as loop-mediated isothermal amplification (LAMP) require pure nucleic acid free of any polymerase inhibitors as its substrate. This in turn, warrants the use of spin-column mediated extraction with centralized high-speed centrifuges. Additionally, the utilization of centralized real-time fluorescence readout and TaqMan-like molecular probes in qRT-PCR and real-time LAMP add cost and restrict their deployment. To circumvent these disadvantages, we report a novel sample-to-answer workflow comprising an indirect sequence-specific magneto-extraction (also referred to as magnetocapture, magneto-preconcentration, or magneto-enrichment) for detecting SARS-CoV-2 nucleic acid. It was followed by in situ fluorescence or electrochemical LAMP. After in silico validation of the approach's sequence selectivity against SARS-CoV-2 variants of concern, the comparative performance of indirect and direct magnetocapture in detecting SARS-CoV-2 nucleic acid in the presence of excess host nucleic acid or serum was probed. After proven superior, the sensitivity of the indirect sequence-specific magnetocapture in conjunction with electrochemical LAMP was investigated. In each case, its sensitivity was assessed through the detection of clinically relevant 10(2) and 10(3) copies of target nucleic acid. Overall, a highly specific nucleic acid detection method was established that can be accommodated for either centralized real-time SYBR-based fluorescence LAMP or portable electrochemical LAMP. Elsevier B.V. 2023-01-15 2022-08-12 /pmc/articles/PMC9373715/ /pubmed/35985192 http://dx.doi.org/10.1016/j.talanta.2022.123809 Text en © 2022 Elsevier B.V. All rights reserved. Since January 2020 Elsevier has created a COVID-19 resource centre with free information in English and Mandarin on the novel coronavirus COVID-19. The COVID-19 resource centre is hosted on Elsevier Connect, the company's public news and information website. Elsevier hereby grants permission to make all its COVID-19-related research that is available on the COVID-19 resource centre - including this research content - immediately available in PubMed Central and other publicly funded repositories, such as the WHO COVID database with rights for unrestricted research re-use and analyses in any form or by any means with acknowledgement of the original source. These permissions are granted for free by Elsevier for as long as the COVID-19 resource centre remains active. |
spellingShingle | Article Tripathy, Sayantan Agarkar, Tanvi Talukdar, Arunansu Sengupta, Mrittika Kumar, Ashvani Ghosh, Souradyuti Evaluation of indirect sequence-specific magneto-extraction-aided LAMP for fluorescence and electrochemical SARS-CoV-2 nucleic acid detection |
title | Evaluation of indirect sequence-specific magneto-extraction-aided LAMP for fluorescence and electrochemical SARS-CoV-2 nucleic acid detection |
title_full | Evaluation of indirect sequence-specific magneto-extraction-aided LAMP for fluorescence and electrochemical SARS-CoV-2 nucleic acid detection |
title_fullStr | Evaluation of indirect sequence-specific magneto-extraction-aided LAMP for fluorescence and electrochemical SARS-CoV-2 nucleic acid detection |
title_full_unstemmed | Evaluation of indirect sequence-specific magneto-extraction-aided LAMP for fluorescence and electrochemical SARS-CoV-2 nucleic acid detection |
title_short | Evaluation of indirect sequence-specific magneto-extraction-aided LAMP for fluorescence and electrochemical SARS-CoV-2 nucleic acid detection |
title_sort | evaluation of indirect sequence-specific magneto-extraction-aided lamp for fluorescence and electrochemical sars-cov-2 nucleic acid detection |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9373715/ https://www.ncbi.nlm.nih.gov/pubmed/35985192 http://dx.doi.org/10.1016/j.talanta.2022.123809 |
work_keys_str_mv | AT tripathysayantan evaluationofindirectsequencespecificmagnetoextractionaidedlampforfluorescenceandelectrochemicalsarscov2nucleicaciddetection AT agarkartanvi evaluationofindirectsequencespecificmagnetoextractionaidedlampforfluorescenceandelectrochemicalsarscov2nucleicaciddetection AT talukdararunansu evaluationofindirectsequencespecificmagnetoextractionaidedlampforfluorescenceandelectrochemicalsarscov2nucleicaciddetection AT senguptamrittika evaluationofindirectsequencespecificmagnetoextractionaidedlampforfluorescenceandelectrochemicalsarscov2nucleicaciddetection AT kumarashvani evaluationofindirectsequencespecificmagnetoextractionaidedlampforfluorescenceandelectrochemicalsarscov2nucleicaciddetection AT ghoshsouradyuti evaluationofindirectsequencespecificmagnetoextractionaidedlampforfluorescenceandelectrochemicalsarscov2nucleicaciddetection |