Cargando…
Comparison of radial endobronchial ultrasound-guided transbronchial lung biopsy with distance measurement versus with guide sheath in diagnosing peripheral pulmonary lesions with a diameter ≥3 cm by thin bronchoscope
OBJECTIVE: This study aims to explore the diagnostic values of radial endobronchial ultrasound-guided transbronchial lung biopsy with distance (rEBUS-D-TBLB) measurement and with guide sheath (rEBUS-GS-TBLB) for peripheral pulmonary lesions (PPLs) with a diameter ≥3 cm by thin bronchoscope. PATIENTS...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Wolters Kluwer - Medknow
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9374119/ https://www.ncbi.nlm.nih.gov/pubmed/35968399 http://dx.doi.org/10.4103/atm.atm_495_21 |
_version_ | 1784767721866526720 |
---|---|
author | Guan, Shuhong Zhou, Jun Zhang, Qiudi Xu, Qianqian Xu, Xiong Zhang, Sujuan |
author_facet | Guan, Shuhong Zhou, Jun Zhang, Qiudi Xu, Qianqian Xu, Xiong Zhang, Sujuan |
author_sort | Guan, Shuhong |
collection | PubMed |
description | OBJECTIVE: This study aims to explore the diagnostic values of radial endobronchial ultrasound-guided transbronchial lung biopsy with distance (rEBUS-D-TBLB) measurement and with guide sheath (rEBUS-GS-TBLB) for peripheral pulmonary lesions (PPLs) with a diameter ≥3 cm by thin bronchoscope. PATIENTS AND METHODS: Six hundred and three patients with PPL (diameter ≥3 cm) were enrolled in this study. The subjects were divided into the rEBUS-D-TBLB and rEBUS-GS-TBLB groups by the random number table method. Patients were assigned to undergo rEBUS-D-TBLB or rEBUS-GS-TBLB, respectively. The histopathology, positive diagnosis rates, duration of the procedure, and postoperative adverse effects between the two groups were examined. RESULTS: A total of 569 patients were included in this study according to the inclusion and exclusion criteria, with 282 cases in the rEBUS-D-TBLB group and 287 cases in the rEBUS-GS-TBLB group. For malignant diseases, the positive diagnosis rates of PPL in the outer/inner-middle lung bands and the right-upper/-lower lung lobes by rEBUS-D-TBLB were noninferior to those of rEBUS-GS-TBLB. The duration of the procedure of rEBUS-D-TBLB was longer than that of rEBUS-GS-TBLB. There were 14 cases of hemorrhage >50 mL, 1 case of postoperative chest pain in the rEBUS-D-TBLB group, and 3 cases of hemorrhage >50 mL in the rEBUS-GS-TBLB group. CONCLUSION: REBUS-D-TBLB by thin bronchoscope has a high diagnostic value for PPL with a diameter ≥3 cm, which may be considered a useful alternative for rEBUS-GS-TBLB in the clinic. |
format | Online Article Text |
id | pubmed-9374119 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Wolters Kluwer - Medknow |
record_format | MEDLINE/PubMed |
spelling | pubmed-93741192022-08-13 Comparison of radial endobronchial ultrasound-guided transbronchial lung biopsy with distance measurement versus with guide sheath in diagnosing peripheral pulmonary lesions with a diameter ≥3 cm by thin bronchoscope Guan, Shuhong Zhou, Jun Zhang, Qiudi Xu, Qianqian Xu, Xiong Zhang, Sujuan Ann Thorac Med Original Article OBJECTIVE: This study aims to explore the diagnostic values of radial endobronchial ultrasound-guided transbronchial lung biopsy with distance (rEBUS-D-TBLB) measurement and with guide sheath (rEBUS-GS-TBLB) for peripheral pulmonary lesions (PPLs) with a diameter ≥3 cm by thin bronchoscope. PATIENTS AND METHODS: Six hundred and three patients with PPL (diameter ≥3 cm) were enrolled in this study. The subjects were divided into the rEBUS-D-TBLB and rEBUS-GS-TBLB groups by the random number table method. Patients were assigned to undergo rEBUS-D-TBLB or rEBUS-GS-TBLB, respectively. The histopathology, positive diagnosis rates, duration of the procedure, and postoperative adverse effects between the two groups were examined. RESULTS: A total of 569 patients were included in this study according to the inclusion and exclusion criteria, with 282 cases in the rEBUS-D-TBLB group and 287 cases in the rEBUS-GS-TBLB group. For malignant diseases, the positive diagnosis rates of PPL in the outer/inner-middle lung bands and the right-upper/-lower lung lobes by rEBUS-D-TBLB were noninferior to those of rEBUS-GS-TBLB. The duration of the procedure of rEBUS-D-TBLB was longer than that of rEBUS-GS-TBLB. There were 14 cases of hemorrhage >50 mL, 1 case of postoperative chest pain in the rEBUS-D-TBLB group, and 3 cases of hemorrhage >50 mL in the rEBUS-GS-TBLB group. CONCLUSION: REBUS-D-TBLB by thin bronchoscope has a high diagnostic value for PPL with a diameter ≥3 cm, which may be considered a useful alternative for rEBUS-GS-TBLB in the clinic. Wolters Kluwer - Medknow 2022 2022-07-09 /pmc/articles/PMC9374119/ /pubmed/35968399 http://dx.doi.org/10.4103/atm.atm_495_21 Text en Copyright: © 2022 Annals of Thoracic Medicine https://creativecommons.org/licenses/by-nc-sa/4.0/This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms. |
spellingShingle | Original Article Guan, Shuhong Zhou, Jun Zhang, Qiudi Xu, Qianqian Xu, Xiong Zhang, Sujuan Comparison of radial endobronchial ultrasound-guided transbronchial lung biopsy with distance measurement versus with guide sheath in diagnosing peripheral pulmonary lesions with a diameter ≥3 cm by thin bronchoscope |
title | Comparison of radial endobronchial ultrasound-guided transbronchial lung biopsy with distance measurement versus with guide sheath in diagnosing peripheral pulmonary lesions with a diameter ≥3 cm by thin bronchoscope |
title_full | Comparison of radial endobronchial ultrasound-guided transbronchial lung biopsy with distance measurement versus with guide sheath in diagnosing peripheral pulmonary lesions with a diameter ≥3 cm by thin bronchoscope |
title_fullStr | Comparison of radial endobronchial ultrasound-guided transbronchial lung biopsy with distance measurement versus with guide sheath in diagnosing peripheral pulmonary lesions with a diameter ≥3 cm by thin bronchoscope |
title_full_unstemmed | Comparison of radial endobronchial ultrasound-guided transbronchial lung biopsy with distance measurement versus with guide sheath in diagnosing peripheral pulmonary lesions with a diameter ≥3 cm by thin bronchoscope |
title_short | Comparison of radial endobronchial ultrasound-guided transbronchial lung biopsy with distance measurement versus with guide sheath in diagnosing peripheral pulmonary lesions with a diameter ≥3 cm by thin bronchoscope |
title_sort | comparison of radial endobronchial ultrasound-guided transbronchial lung biopsy with distance measurement versus with guide sheath in diagnosing peripheral pulmonary lesions with a diameter ≥3 cm by thin bronchoscope |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9374119/ https://www.ncbi.nlm.nih.gov/pubmed/35968399 http://dx.doi.org/10.4103/atm.atm_495_21 |
work_keys_str_mv | AT guanshuhong comparisonofradialendobronchialultrasoundguidedtransbronchiallungbiopsywithdistancemeasurementversuswithguidesheathindiagnosingperipheralpulmonarylesionswithadiameter3cmbythinbronchoscope AT zhoujun comparisonofradialendobronchialultrasoundguidedtransbronchiallungbiopsywithdistancemeasurementversuswithguidesheathindiagnosingperipheralpulmonarylesionswithadiameter3cmbythinbronchoscope AT zhangqiudi comparisonofradialendobronchialultrasoundguidedtransbronchiallungbiopsywithdistancemeasurementversuswithguidesheathindiagnosingperipheralpulmonarylesionswithadiameter3cmbythinbronchoscope AT xuqianqian comparisonofradialendobronchialultrasoundguidedtransbronchiallungbiopsywithdistancemeasurementversuswithguidesheathindiagnosingperipheralpulmonarylesionswithadiameter3cmbythinbronchoscope AT xuxiong comparisonofradialendobronchialultrasoundguidedtransbronchiallungbiopsywithdistancemeasurementversuswithguidesheathindiagnosingperipheralpulmonarylesionswithadiameter3cmbythinbronchoscope AT zhangsujuan comparisonofradialendobronchialultrasoundguidedtransbronchiallungbiopsywithdistancemeasurementversuswithguidesheathindiagnosingperipheralpulmonarylesionswithadiameter3cmbythinbronchoscope |