Temperature gradient sensing mechanism using liquid crystal droplets with 0.1-mK-level detection accuracy and high spatial resolution
We proposed the detection mechanism of the micro-levels of temperature gradient in a micro-electromechanical system using the unidirectional rotation of cholesteric-liquid crystal (Ch-LC) droplets. Ch-LC droplets in the presence of an isotropic phase subjected to a heat flux rotate with a speed prop...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Nature Publishing Group UK
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9374739/ https://www.ncbi.nlm.nih.gov/pubmed/35962134 http://dx.doi.org/10.1038/s41598-022-18008-y |
Sumario: | We proposed the detection mechanism of the micro-levels of temperature gradient in a micro-electromechanical system using the unidirectional rotation of cholesteric-liquid crystal (Ch-LC) droplets. Ch-LC droplets in the presence of an isotropic phase subjected to a heat flux rotate with a speed proportional to the magnitude of the temperature gradient. We further quantified the temperature gradient-to-torque conversion efficiency to apply the thermomechanical cross-correlation to the detection of temperature gradient. Then, we observed the rotational behavior of Ch-LC droplets after introducing them onto model devices containing patterned Au thin-film electrodes. Direct electric current applied to these Au electrodes results in unidirectional rotation of the Ch-LC droplets in response to heat flux generated from the Au electrodes. By evaluating the possible temperature gradient detection resolution using Ch-LC droplet rotation, we show that Ch-LC droplets can achieve both high spatial resolution (~ 10 µm) and high detection accuracy (~ 0.1 mK/µm). |
---|