Cargando…

Bigger Is Not Always Better: Effects of Electrocautery Setting on Tissue Injury in a Porcine Model

Introduction Electrosurgery for dissection and hemostasis remains one of the foundational tools for the field of surgery as a whole. Monopolar cautery remains the most utilized modality for achieving the aforementioned goals. Given the prolonged history and pre-modern development of "Bovie"...

Descripción completa

Detalles Bibliográficos
Autores principales: Shiver, Austin L, Webber, Colton, Sliker, Taylor, Rushford, Patrick, Shaw, Aaron
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Cureus 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9375435/
https://www.ncbi.nlm.nih.gov/pubmed/35974853
http://dx.doi.org/10.7759/cureus.26841
_version_ 1784767964104359936
author Shiver, Austin L
Webber, Colton
Sliker, Taylor
Rushford, Patrick
Shaw, Aaron
author_facet Shiver, Austin L
Webber, Colton
Sliker, Taylor
Rushford, Patrick
Shaw, Aaron
author_sort Shiver, Austin L
collection PubMed
description Introduction Electrosurgery for dissection and hemostasis remains one of the foundational tools for the field of surgery as a whole. Monopolar cautery remains the most utilized modality for achieving the aforementioned goals. Given the prolonged history and pre-modern development of "Bovie" cautery, there remains a paucity of data regarding appropriate settings and intensity for various tissue types, procedures, or locales. As a result, utilized settings depend on precedent and personal preference. We aimed to determine the amount of secondary soft tissue injury by volume and depth beyond the electrocautery pen tip in the skin and subcutaneous tissue as well as skeletal muscle.  Methods Porcine samples were used for experimental testing using two testing types: 1) skin and subcutaneous tissue and 2) Skeletal muscle. Sample sizes were standardized at 1 cm3 cubes. For skin samples, tissue injury was created with either a scalpel or electrocautery pen on cut setting, and tested at intensities from 10 to 150 in increments of 10. Skeletal muscle samples were similarly tested using the electrocautery pen only in either a cut or coagulation setting. Samples were tested at incremental intensities from 10 to 120 for both settings. Electrocautery was tested for a period of five seconds with a continuous current. All samples were placed in formalin and underwent histologic staining with hematoxylin and eosin staining to be assessed for the extent of tissue injury in terms of depth, radius, and volume. The measurements were recorded in millimeters. Results For skin incision, there was a positive and significant correlation with respect to the radius (R=.73, p=0.006). When considering intensity with an interval of 10-70 there was a positive and significant correlation with respect to the radius, depth, and volume. The cold knife incision had no notable soft tissue injury beyond the depth of the incision. Regarding skeletal muscle, again, a significant and positive correlation between increasing monopolar settings was noted for both the coagulation and cut functions (R=.84, p=.0005; R=0.84, p=0.0006). A positive correlation was found between increasing cut intensity and volume of soft tissue injury (R=0.73, p=.008); this was not reflected in the coagulation setting. When limited to an intensity range of 10-60, a significant relationship was noted for depth, radius and volume (R=.95, p= <0.001; R=0.98, p= <.001; R=.92, p=.001). Conclusion In all samples, apart from the cold knife skin incision, additional soft tissue injury beyond the tip of the electrocautery pen was noted. Given our findings, recommendations include using the lowest setting required for the purposes of the given surgical case as well as minimizing electrocautery use for skin incisions given its association with a larger volume of tissue injury in comparison with a scalpel. Additionally, electrocautery should be used with care in, and around neurovascular structures as soft tissue injury did occur several millimeters beyond the tip of the electrocautery pen. Further study is needed to see if these patterns are similar in living animals as well as human tissue and whether they bear any clinical impact on surgical wound healing or other surgical complications.
format Online
Article
Text
id pubmed-9375435
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Cureus
record_format MEDLINE/PubMed
spelling pubmed-93754352022-08-15 Bigger Is Not Always Better: Effects of Electrocautery Setting on Tissue Injury in a Porcine Model Shiver, Austin L Webber, Colton Sliker, Taylor Rushford, Patrick Shaw, Aaron Cureus Orthopedics Introduction Electrosurgery for dissection and hemostasis remains one of the foundational tools for the field of surgery as a whole. Monopolar cautery remains the most utilized modality for achieving the aforementioned goals. Given the prolonged history and pre-modern development of "Bovie" cautery, there remains a paucity of data regarding appropriate settings and intensity for various tissue types, procedures, or locales. As a result, utilized settings depend on precedent and personal preference. We aimed to determine the amount of secondary soft tissue injury by volume and depth beyond the electrocautery pen tip in the skin and subcutaneous tissue as well as skeletal muscle.  Methods Porcine samples were used for experimental testing using two testing types: 1) skin and subcutaneous tissue and 2) Skeletal muscle. Sample sizes were standardized at 1 cm3 cubes. For skin samples, tissue injury was created with either a scalpel or electrocautery pen on cut setting, and tested at intensities from 10 to 150 in increments of 10. Skeletal muscle samples were similarly tested using the electrocautery pen only in either a cut or coagulation setting. Samples were tested at incremental intensities from 10 to 120 for both settings. Electrocautery was tested for a period of five seconds with a continuous current. All samples were placed in formalin and underwent histologic staining with hematoxylin and eosin staining to be assessed for the extent of tissue injury in terms of depth, radius, and volume. The measurements were recorded in millimeters. Results For skin incision, there was a positive and significant correlation with respect to the radius (R=.73, p=0.006). When considering intensity with an interval of 10-70 there was a positive and significant correlation with respect to the radius, depth, and volume. The cold knife incision had no notable soft tissue injury beyond the depth of the incision. Regarding skeletal muscle, again, a significant and positive correlation between increasing monopolar settings was noted for both the coagulation and cut functions (R=.84, p=.0005; R=0.84, p=0.0006). A positive correlation was found between increasing cut intensity and volume of soft tissue injury (R=0.73, p=.008); this was not reflected in the coagulation setting. When limited to an intensity range of 10-60, a significant relationship was noted for depth, radius and volume (R=.95, p= <0.001; R=0.98, p= <.001; R=.92, p=.001). Conclusion In all samples, apart from the cold knife skin incision, additional soft tissue injury beyond the tip of the electrocautery pen was noted. Given our findings, recommendations include using the lowest setting required for the purposes of the given surgical case as well as minimizing electrocautery use for skin incisions given its association with a larger volume of tissue injury in comparison with a scalpel. Additionally, electrocautery should be used with care in, and around neurovascular structures as soft tissue injury did occur several millimeters beyond the tip of the electrocautery pen. Further study is needed to see if these patterns are similar in living animals as well as human tissue and whether they bear any clinical impact on surgical wound healing or other surgical complications. Cureus 2022-07-14 /pmc/articles/PMC9375435/ /pubmed/35974853 http://dx.doi.org/10.7759/cureus.26841 Text en Copyright © 2022, Shiver et al. https://creativecommons.org/licenses/by/3.0/This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Orthopedics
Shiver, Austin L
Webber, Colton
Sliker, Taylor
Rushford, Patrick
Shaw, Aaron
Bigger Is Not Always Better: Effects of Electrocautery Setting on Tissue Injury in a Porcine Model
title Bigger Is Not Always Better: Effects of Electrocautery Setting on Tissue Injury in a Porcine Model
title_full Bigger Is Not Always Better: Effects of Electrocautery Setting on Tissue Injury in a Porcine Model
title_fullStr Bigger Is Not Always Better: Effects of Electrocautery Setting on Tissue Injury in a Porcine Model
title_full_unstemmed Bigger Is Not Always Better: Effects of Electrocautery Setting on Tissue Injury in a Porcine Model
title_short Bigger Is Not Always Better: Effects of Electrocautery Setting on Tissue Injury in a Porcine Model
title_sort bigger is not always better: effects of electrocautery setting on tissue injury in a porcine model
topic Orthopedics
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9375435/
https://www.ncbi.nlm.nih.gov/pubmed/35974853
http://dx.doi.org/10.7759/cureus.26841
work_keys_str_mv AT shiveraustinl biggerisnotalwaysbettereffectsofelectrocauterysettingontissueinjuryinaporcinemodel
AT webbercolton biggerisnotalwaysbettereffectsofelectrocauterysettingontissueinjuryinaporcinemodel
AT slikertaylor biggerisnotalwaysbettereffectsofelectrocauterysettingontissueinjuryinaporcinemodel
AT rushfordpatrick biggerisnotalwaysbettereffectsofelectrocauterysettingontissueinjuryinaporcinemodel
AT shawaaron biggerisnotalwaysbettereffectsofelectrocauterysettingontissueinjuryinaporcinemodel