Dosimetric Importance of Implementing Jaw Tracking Technique in Radiotherapy Treatment Plan Execution

OBJECTIVE: To study the dosimetric importance of Jaw tracking technique in reducing the doses to organs at risk (OAR) while achieving the optimal dose coverage for the target. METHODS: We retrospectively selected ten Glioblastoma cases and for each patient, two plans were created namely Static Jaw T...

Descripción completa

Detalles Bibliográficos
Autores principales: V T, Hridya, Khanna, D, Raj, Aswathi, Padmanabhan, Sathish, P, Mohandass
Formato: Online Artículo Texto
Lenguaje:English
Publicado: West Asia Organization for Cancer Prevention 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9375617/
https://www.ncbi.nlm.nih.gov/pubmed/35485702
http://dx.doi.org/10.31557/APJCP.2022.23.4.1397
_version_ 1784768003780378624
author V T, Hridya
Khanna, D
Raj, Aswathi
Padmanabhan, Sathish
P, Mohandass
author_facet V T, Hridya
Khanna, D
Raj, Aswathi
Padmanabhan, Sathish
P, Mohandass
author_sort V T, Hridya
collection PubMed
description OBJECTIVE: To study the dosimetric importance of Jaw tracking technique in reducing the doses to organs at risk (OAR) while achieving the optimal dose coverage for the target. METHODS: We retrospectively selected ten Glioblastoma cases and for each patient, two plans were created namely Static Jaw Technique Dynamic Intensity Modulated Radiotherapy plan and Jaw Tracking Technique D-IMRT plan with 6 MV for Varian Truebeam™ STx machine using Eclipse Treatment planning system. Both plans were analyzed and compared based on various dosimetric parameters for Planning Target Volume (PTV) and OARs. The dose agreement between the Portal dose image prediction and the portal dosimetry measurement was also analysed using gamma analysis criteria of 3%/3mm, 2%/2mm and 1%/1mm of dose distance/distance-to-agreement. RESULTS: The dosimetric parameters evaluated for both plans showed that most of the parameters gave significant P values, where D50% of PTV showed a mean difference (Δ) of 0.45 with significant P value, 0.0104. Similarly mean dose, D2%, D98%, D80% to PTV, Conformity Index and Conformation number showed Δ values of 0.45, 0.51, 0.41, 0.40, 0.02 and 0.01 with their significant P values as 0.0138, 0.0172, 0.0313, 0.0466, 0.0279, 0.0561 respectively. The Δ values and significant P values obtained among OARs are 0.54;0.0224 for brainstem, 0.54;0.0017 for RT optic nerve, 0.52;0.0001 for LT optic nerve, 0.59;0.0040 for optic chiasm and for the healthy tissues it showed the values with their mean dose, V5 and V30 parameters as 0.19;0.0115, 0.59;0.0067 and 0.25;0.0125 respectively. The JTT plans showed better passing results of gamma analysis criteria when compared to SJT plans. CONCLUSION: The findings in the studies emphasize the importance of using JTT technique in the radiotherapy treatment plans as it lowers the risk of acute or late toxicity and secondary radiogenic cancers in patients by reducing the OAR doses and achieves better tumor control.
format Online
Article
Text
id pubmed-9375617
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher West Asia Organization for Cancer Prevention
record_format MEDLINE/PubMed
spelling pubmed-93756172022-08-19 Dosimetric Importance of Implementing Jaw Tracking Technique in Radiotherapy Treatment Plan Execution V T, Hridya Khanna, D Raj, Aswathi Padmanabhan, Sathish P, Mohandass Asian Pac J Cancer Prev Research Article OBJECTIVE: To study the dosimetric importance of Jaw tracking technique in reducing the doses to organs at risk (OAR) while achieving the optimal dose coverage for the target. METHODS: We retrospectively selected ten Glioblastoma cases and for each patient, two plans were created namely Static Jaw Technique Dynamic Intensity Modulated Radiotherapy plan and Jaw Tracking Technique D-IMRT plan with 6 MV for Varian Truebeam™ STx machine using Eclipse Treatment planning system. Both plans were analyzed and compared based on various dosimetric parameters for Planning Target Volume (PTV) and OARs. The dose agreement between the Portal dose image prediction and the portal dosimetry measurement was also analysed using gamma analysis criteria of 3%/3mm, 2%/2mm and 1%/1mm of dose distance/distance-to-agreement. RESULTS: The dosimetric parameters evaluated for both plans showed that most of the parameters gave significant P values, where D50% of PTV showed a mean difference (Δ) of 0.45 with significant P value, 0.0104. Similarly mean dose, D2%, D98%, D80% to PTV, Conformity Index and Conformation number showed Δ values of 0.45, 0.51, 0.41, 0.40, 0.02 and 0.01 with their significant P values as 0.0138, 0.0172, 0.0313, 0.0466, 0.0279, 0.0561 respectively. The Δ values and significant P values obtained among OARs are 0.54;0.0224 for brainstem, 0.54;0.0017 for RT optic nerve, 0.52;0.0001 for LT optic nerve, 0.59;0.0040 for optic chiasm and for the healthy tissues it showed the values with their mean dose, V5 and V30 parameters as 0.19;0.0115, 0.59;0.0067 and 0.25;0.0125 respectively. The JTT plans showed better passing results of gamma analysis criteria when compared to SJT plans. CONCLUSION: The findings in the studies emphasize the importance of using JTT technique in the radiotherapy treatment plans as it lowers the risk of acute or late toxicity and secondary radiogenic cancers in patients by reducing the OAR doses and achieves better tumor control. West Asia Organization for Cancer Prevention 2022-04 /pmc/articles/PMC9375617/ /pubmed/35485702 http://dx.doi.org/10.31557/APJCP.2022.23.4.1397 Text en https://creativecommons.org/licenses/by-nc/4.0/This work is licensed under a Creative Commons Attribution-Non Commercial 4.0 International License. https://creativecommons.org/licenses/by-nc/4.0/
spellingShingle Research Article
V T, Hridya
Khanna, D
Raj, Aswathi
Padmanabhan, Sathish
P, Mohandass
Dosimetric Importance of Implementing Jaw Tracking Technique in Radiotherapy Treatment Plan Execution
title Dosimetric Importance of Implementing Jaw Tracking Technique in Radiotherapy Treatment Plan Execution
title_full Dosimetric Importance of Implementing Jaw Tracking Technique in Radiotherapy Treatment Plan Execution
title_fullStr Dosimetric Importance of Implementing Jaw Tracking Technique in Radiotherapy Treatment Plan Execution
title_full_unstemmed Dosimetric Importance of Implementing Jaw Tracking Technique in Radiotherapy Treatment Plan Execution
title_short Dosimetric Importance of Implementing Jaw Tracking Technique in Radiotherapy Treatment Plan Execution
title_sort dosimetric importance of implementing jaw tracking technique in radiotherapy treatment plan execution
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9375617/
https://www.ncbi.nlm.nih.gov/pubmed/35485702
http://dx.doi.org/10.31557/APJCP.2022.23.4.1397
work_keys_str_mv AT vthridya dosimetricimportanceofimplementingjawtrackingtechniqueinradiotherapytreatmentplanexecution
AT khannad dosimetricimportanceofimplementingjawtrackingtechniqueinradiotherapytreatmentplanexecution
AT rajaswathi dosimetricimportanceofimplementingjawtrackingtechniqueinradiotherapytreatmentplanexecution
AT padmanabhansathish dosimetricimportanceofimplementingjawtrackingtechniqueinradiotherapytreatmentplanexecution
AT pmohandass dosimetricimportanceofimplementingjawtrackingtechniqueinradiotherapytreatmentplanexecution