Atrial fibrillation (AF) is one of the most common cardiac arrhythmias encountered. Aggressive and appropriate management, along with identification and modification of risk factors, remains at the forefront of evidence-based practice. Thrombus formation (primarily in the left atrial appendage) and...

Descripción completa

Detalles Bibliográficos
Autores principales: Patel, Palak, Ganta, Nagapratap, Filice, Giuseppe, Richard, Ivan, Acquah, Frederick, Alnabwani, Dina, Patel, Harshil B
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Cureus 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9376013/
https://www.ncbi.nlm.nih.gov/pubmed/35978763
http://dx.doi.org/10.7759/cureus.26892
_version_ 1784768072470495232
author Patel, Palak
Ganta, Nagapratap
Filice, Giuseppe
Richard, Ivan
Acquah, Frederick
Alnabwani, Dina
Patel, Harshil B
author_facet Patel, Palak
Ganta, Nagapratap
Filice, Giuseppe
Richard, Ivan
Acquah, Frederick
Alnabwani, Dina
Patel, Harshil B
author_sort Patel, Palak
collection PubMed
description Atrial fibrillation (AF) is one of the most common cardiac arrhythmias encountered. Aggressive and appropriate management, along with identification and modification of risk factors, remains at the forefront of evidence-based practice. Thrombus formation (primarily in the left atrial appendage) and consequent thromboembolism are risks associated with AF. Anticoagulation is utilized to prevent and reduce AF-induced complications such as stroke, heart failure, and death. However, in instances when the risk of bleeding from anticoagulation outweighs the benefits of stroke prevention, other modalities such as left atrial appendage closure (LAAC) devices like the WATCHMAN device (Boston Scientific, MA) are utilized. LAAC devices, such as the WATCHMAN device, are also not without significant risks, one of them being device-related thrombus (DRT) formation. We present a case of device-related thrombus formation post WATCHMAN implantation and a subsequent embolic cerebrovascular accident (CVA).
format Online
Article
Text
id pubmed-9376013
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Cureus
record_format MEDLINE/PubMed
spelling pubmed-93760132022-08-16 Embolic Cerebrovascular Accident Secondary to Device-Related Thrombus Post WATCHMAN Device Implantation Patel, Palak Ganta, Nagapratap Filice, Giuseppe Richard, Ivan Acquah, Frederick Alnabwani, Dina Patel, Harshil B Cureus Cardiology Atrial fibrillation (AF) is one of the most common cardiac arrhythmias encountered. Aggressive and appropriate management, along with identification and modification of risk factors, remains at the forefront of evidence-based practice. Thrombus formation (primarily in the left atrial appendage) and consequent thromboembolism are risks associated with AF. Anticoagulation is utilized to prevent and reduce AF-induced complications such as stroke, heart failure, and death. However, in instances when the risk of bleeding from anticoagulation outweighs the benefits of stroke prevention, other modalities such as left atrial appendage closure (LAAC) devices like the WATCHMAN device (Boston Scientific, MA) are utilized. LAAC devices, such as the WATCHMAN device, are also not without significant risks, one of them being device-related thrombus (DRT) formation. We present a case of device-related thrombus formation post WATCHMAN implantation and a subsequent embolic cerebrovascular accident (CVA). Cureus 2022-07-15 /pmc/articles/PMC9376013/ /pubmed/35978763 http://dx.doi.org/10.7759/cureus.26892 Text en Copyright © 2022, Patel et al. https://creativecommons.org/licenses/by/3.0/This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Cardiology
Patel, Palak
Ganta, Nagapratap
Filice, Giuseppe
Richard, Ivan
Acquah, Frederick
Alnabwani, Dina
Patel, Harshil B
Embolic Cerebrovascular Accident Secondary to Device-Related Thrombus Post WATCHMAN Device Implantation
title Embolic Cerebrovascular Accident Secondary to Device-Related Thrombus Post WATCHMAN Device Implantation
title_full Embolic Cerebrovascular Accident Secondary to Device-Related Thrombus Post WATCHMAN Device Implantation
title_fullStr Embolic Cerebrovascular Accident Secondary to Device-Related Thrombus Post WATCHMAN Device Implantation
title_full_unstemmed Embolic Cerebrovascular Accident Secondary to Device-Related Thrombus Post WATCHMAN Device Implantation
title_short Embolic Cerebrovascular Accident Secondary to Device-Related Thrombus Post WATCHMAN Device Implantation
title_sort embolic cerebrovascular accident secondary to device-related thrombus post watchman device implantation
topic Cardiology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9376013/
https://www.ncbi.nlm.nih.gov/pubmed/35978763
http://dx.doi.org/10.7759/cureus.26892
work_keys_str_mv AT patelpalak emboliccerebrovascularaccidentsecondarytodevicerelatedthrombuspostwatchmandeviceimplantation
AT gantanagapratap emboliccerebrovascularaccidentsecondarytodevicerelatedthrombuspostwatchmandeviceimplantation
AT filicegiuseppe emboliccerebrovascularaccidentsecondarytodevicerelatedthrombuspostwatchmandeviceimplantation
AT richardivan emboliccerebrovascularaccidentsecondarytodevicerelatedthrombuspostwatchmandeviceimplantation
AT acquahfrederick emboliccerebrovascularaccidentsecondarytodevicerelatedthrombuspostwatchmandeviceimplantation
AT alnabwanidina emboliccerebrovascularaccidentsecondarytodevicerelatedthrombuspostwatchmandeviceimplantation
AT patelharshilb emboliccerebrovascularaccidentsecondarytodevicerelatedthrombuspostwatchmandeviceimplantation