Cargando…

A high-throughput microfluidic device based on controlled incremental filtration to enable centrifugation-free, low extracorporeal volume leukapheresis

Leukapheresis, the extracorporeal separation of white blood cells (WBCs) from red blood cells (RBCs) and platelets (PLTs), is a life-saving procedure used for treating patients with cancer and other conditions, and as the initial step in the manufacturing of cellular and gene-based therapies. Well-t...

Descripción completa

Detalles Bibliográficos
Autores principales: Lezzar, Dalia L., Lam, Fong W., Huerta, Ravin, Mukhamedshin, Anton, Lu, Madeleine, Shevkoplyas, Sergey S.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group UK 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9376077/
https://www.ncbi.nlm.nih.gov/pubmed/35963876
http://dx.doi.org/10.1038/s41598-022-16748-5
_version_ 1784768085835644928
author Lezzar, Dalia L.
Lam, Fong W.
Huerta, Ravin
Mukhamedshin, Anton
Lu, Madeleine
Shevkoplyas, Sergey S.
author_facet Lezzar, Dalia L.
Lam, Fong W.
Huerta, Ravin
Mukhamedshin, Anton
Lu, Madeleine
Shevkoplyas, Sergey S.
author_sort Lezzar, Dalia L.
collection PubMed
description Leukapheresis, the extracorporeal separation of white blood cells (WBCs) from red blood cells (RBCs) and platelets (PLTs), is a life-saving procedure used for treating patients with cancer and other conditions, and as the initial step in the manufacturing of cellular and gene-based therapies. Well-tolerated by adults, leukapheresis poses a significant risk to neonates and low-weight infants because the extracorporeal volume (ECV) of standard centrifugation-based machines represents a particularly large fraction of these patients’ total blood volume. Here we describe a novel high-throughput microfluidic device (with a void volume of 0.4 mL) based on controlled incremental filtration (CIF) technology that could replace centrifugation for performing leukapheresis. The CIF device was tested extensively using whole blood from healthy volunteers at multiple hematocrits (5–30%) and flow rates (10–30 mL/min). In the flow-through regime, the CIF device separated WBCs with > 85% efficiency and 10–15% loss of RBCs and PLTs while processing whole blood diluted with saline to 10% hematocrit at a flow rate of 10 mL/min. In the recirculation regime, the CIF device demonstrated a similar level of separation performance, virtually depleting WBCs in the recirculating blood (~ 98% reduction) by the end of a 3.5-hour simulated leukapheresis procedure. Importantly, the device operated without clogging or decline in separation performance, with minimal activation of WBCs and PLTs and no measurable damage to RBCs. Compared to the typical parameters of centrifugation-based leukapheresis, the CIF device had a void volume at least 100-fold smaller, removed WBCs about twice as fast, and lost ~ 2–3-fold fewer PLTs, while operating at a flow rate compatible with the current practice. The hematocrit and flow rate at which the CIF device operated were significantly higher than previously published for other microfluidic cell separation methods. Finally, this study is the first to demonstrate a highly efficient separation of cells from recirculating blood using a microfluidic device. Overall, these findings suggest the feasibility of using high-throughput microfluidic cell separation technology to ultimately enable centrifugation-free, low-ECV leukapheresis. Such a capability would be particularly useful in young children, a vulnerable group of patients who are currently underserved.
format Online
Article
Text
id pubmed-9376077
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Nature Publishing Group UK
record_format MEDLINE/PubMed
spelling pubmed-93760772022-08-15 A high-throughput microfluidic device based on controlled incremental filtration to enable centrifugation-free, low extracorporeal volume leukapheresis Lezzar, Dalia L. Lam, Fong W. Huerta, Ravin Mukhamedshin, Anton Lu, Madeleine Shevkoplyas, Sergey S. Sci Rep Article Leukapheresis, the extracorporeal separation of white blood cells (WBCs) from red blood cells (RBCs) and platelets (PLTs), is a life-saving procedure used for treating patients with cancer and other conditions, and as the initial step in the manufacturing of cellular and gene-based therapies. Well-tolerated by adults, leukapheresis poses a significant risk to neonates and low-weight infants because the extracorporeal volume (ECV) of standard centrifugation-based machines represents a particularly large fraction of these patients’ total blood volume. Here we describe a novel high-throughput microfluidic device (with a void volume of 0.4 mL) based on controlled incremental filtration (CIF) technology that could replace centrifugation for performing leukapheresis. The CIF device was tested extensively using whole blood from healthy volunteers at multiple hematocrits (5–30%) and flow rates (10–30 mL/min). In the flow-through regime, the CIF device separated WBCs with > 85% efficiency and 10–15% loss of RBCs and PLTs while processing whole blood diluted with saline to 10% hematocrit at a flow rate of 10 mL/min. In the recirculation regime, the CIF device demonstrated a similar level of separation performance, virtually depleting WBCs in the recirculating blood (~ 98% reduction) by the end of a 3.5-hour simulated leukapheresis procedure. Importantly, the device operated without clogging or decline in separation performance, with minimal activation of WBCs and PLTs and no measurable damage to RBCs. Compared to the typical parameters of centrifugation-based leukapheresis, the CIF device had a void volume at least 100-fold smaller, removed WBCs about twice as fast, and lost ~ 2–3-fold fewer PLTs, while operating at a flow rate compatible with the current practice. The hematocrit and flow rate at which the CIF device operated were significantly higher than previously published for other microfluidic cell separation methods. Finally, this study is the first to demonstrate a highly efficient separation of cells from recirculating blood using a microfluidic device. Overall, these findings suggest the feasibility of using high-throughput microfluidic cell separation technology to ultimately enable centrifugation-free, low-ECV leukapheresis. Such a capability would be particularly useful in young children, a vulnerable group of patients who are currently underserved. Nature Publishing Group UK 2022-08-13 /pmc/articles/PMC9376077/ /pubmed/35963876 http://dx.doi.org/10.1038/s41598-022-16748-5 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Article
Lezzar, Dalia L.
Lam, Fong W.
Huerta, Ravin
Mukhamedshin, Anton
Lu, Madeleine
Shevkoplyas, Sergey S.
A high-throughput microfluidic device based on controlled incremental filtration to enable centrifugation-free, low extracorporeal volume leukapheresis
title A high-throughput microfluidic device based on controlled incremental filtration to enable centrifugation-free, low extracorporeal volume leukapheresis
title_full A high-throughput microfluidic device based on controlled incremental filtration to enable centrifugation-free, low extracorporeal volume leukapheresis
title_fullStr A high-throughput microfluidic device based on controlled incremental filtration to enable centrifugation-free, low extracorporeal volume leukapheresis
title_full_unstemmed A high-throughput microfluidic device based on controlled incremental filtration to enable centrifugation-free, low extracorporeal volume leukapheresis
title_short A high-throughput microfluidic device based on controlled incremental filtration to enable centrifugation-free, low extracorporeal volume leukapheresis
title_sort high-throughput microfluidic device based on controlled incremental filtration to enable centrifugation-free, low extracorporeal volume leukapheresis
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9376077/
https://www.ncbi.nlm.nih.gov/pubmed/35963876
http://dx.doi.org/10.1038/s41598-022-16748-5
work_keys_str_mv AT lezzardalial ahighthroughputmicrofluidicdevicebasedoncontrolledincrementalfiltrationtoenablecentrifugationfreelowextracorporealvolumeleukapheresis
AT lamfongw ahighthroughputmicrofluidicdevicebasedoncontrolledincrementalfiltrationtoenablecentrifugationfreelowextracorporealvolumeleukapheresis
AT huertaravin ahighthroughputmicrofluidicdevicebasedoncontrolledincrementalfiltrationtoenablecentrifugationfreelowextracorporealvolumeleukapheresis
AT mukhamedshinanton ahighthroughputmicrofluidicdevicebasedoncontrolledincrementalfiltrationtoenablecentrifugationfreelowextracorporealvolumeleukapheresis
AT lumadeleine ahighthroughputmicrofluidicdevicebasedoncontrolledincrementalfiltrationtoenablecentrifugationfreelowextracorporealvolumeleukapheresis
AT shevkoplyassergeys ahighthroughputmicrofluidicdevicebasedoncontrolledincrementalfiltrationtoenablecentrifugationfreelowextracorporealvolumeleukapheresis
AT lezzardalial highthroughputmicrofluidicdevicebasedoncontrolledincrementalfiltrationtoenablecentrifugationfreelowextracorporealvolumeleukapheresis
AT lamfongw highthroughputmicrofluidicdevicebasedoncontrolledincrementalfiltrationtoenablecentrifugationfreelowextracorporealvolumeleukapheresis
AT huertaravin highthroughputmicrofluidicdevicebasedoncontrolledincrementalfiltrationtoenablecentrifugationfreelowextracorporealvolumeleukapheresis
AT mukhamedshinanton highthroughputmicrofluidicdevicebasedoncontrolledincrementalfiltrationtoenablecentrifugationfreelowextracorporealvolumeleukapheresis
AT lumadeleine highthroughputmicrofluidicdevicebasedoncontrolledincrementalfiltrationtoenablecentrifugationfreelowextracorporealvolumeleukapheresis
AT shevkoplyassergeys highthroughputmicrofluidicdevicebasedoncontrolledincrementalfiltrationtoenablecentrifugationfreelowextracorporealvolumeleukapheresis