Cargando…
The accuracy of pulse oximetry in measuring oxygen saturation by levels of skin pigmentation: a systematic review and meta-analysis
BACKGROUND: During the COVID-19 pandemic, there have been concerns regarding potential bias in pulse oximetry measurements for people with high levels of skin pigmentation. We systematically reviewed the effects of skin pigmentation on the accuracy of oxygen saturation measurement by pulse oximetry...
Autores principales: | , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9377806/ https://www.ncbi.nlm.nih.gov/pubmed/35971142 http://dx.doi.org/10.1186/s12916-022-02452-8 |
_version_ | 1784768408605163520 |
---|---|
author | Shi, Chunhu Goodall, Mark Dumville, Jo Hill, James Norman, Gill Hamer, Oliver Clegg, Andrew Watkins, Caroline Leigh Georgiou, George Hodkinson, Alexander Lightbody, Catherine Elizabeth Dark, Paul Cullum, Nicky |
author_facet | Shi, Chunhu Goodall, Mark Dumville, Jo Hill, James Norman, Gill Hamer, Oliver Clegg, Andrew Watkins, Caroline Leigh Georgiou, George Hodkinson, Alexander Lightbody, Catherine Elizabeth Dark, Paul Cullum, Nicky |
author_sort | Shi, Chunhu |
collection | PubMed |
description | BACKGROUND: During the COVID-19 pandemic, there have been concerns regarding potential bias in pulse oximetry measurements for people with high levels of skin pigmentation. We systematically reviewed the effects of skin pigmentation on the accuracy of oxygen saturation measurement by pulse oximetry (SpO(2)) compared with the gold standard SaO(2) measured by CO-oximetry. METHODS: We searched Ovid MEDLINE, Ovid Embase, EBSCO CINAHL, ClinicalTrials.gov, and WHO International Clinical Trials Registry Platform (up to December 2021) for studies with SpO(2)–SaO(2) comparisons and measuring the impact of skin pigmentation or ethnicity on pulse oximetry accuracy. We performed meta-analyses for mean bias (the primary outcome in this review) and its standard deviations (SDs) across studies included for each subgroup of skin pigmentation and ethnicity and used these pooled mean biases and SDs to calculate accuracy root-mean-square (A(rms)) and 95% limits of agreement. The review was registered with the Open Science Framework (https://osf.io/gm7ty). RESULTS: We included 32 studies (6505 participants): 15 measured skin pigmentation and 22 referred to ethnicity. Compared with standard SaO(2) measurement, pulse oximetry probably overestimates oxygen saturation in people with the high level of skin pigmentation (pooled mean bias 1.11%; 95% confidence interval 0.29 to 1.93%) and people described as Black/African American (1.52%; 0.95 to 2.09%) (moderate- and low-certainty evidence). The bias of pulse oximetry measurements for people with other levels of skin pigmentation or those from other ethnic groups is either more uncertain or suggests no overestimation. Whilst the extent of mean bias is small or negligible for all subgroups evaluated, the associated imprecision is unacceptably large (pooled SDs > 1%). When the extent of measurement bias and precision is considered jointly, pulse oximetry measurements for all the subgroups appear acceptably accurate (with A(rms) < 4%). CONCLUSIONS: Pulse oximetry may overestimate oxygen saturation in people with high levels of skin pigmentation and people whose ethnicity is reported as Black/African American, compared with SaO(2). The extent of overestimation may be small in hospital settings but unknown in community settings. REVIEW PROTOCOL REGISTRATION: https://osf.io/gm7ty SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s12916-022-02452-8. |
format | Online Article Text |
id | pubmed-9377806 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-93778062022-08-16 The accuracy of pulse oximetry in measuring oxygen saturation by levels of skin pigmentation: a systematic review and meta-analysis Shi, Chunhu Goodall, Mark Dumville, Jo Hill, James Norman, Gill Hamer, Oliver Clegg, Andrew Watkins, Caroline Leigh Georgiou, George Hodkinson, Alexander Lightbody, Catherine Elizabeth Dark, Paul Cullum, Nicky BMC Med Research Article BACKGROUND: During the COVID-19 pandemic, there have been concerns regarding potential bias in pulse oximetry measurements for people with high levels of skin pigmentation. We systematically reviewed the effects of skin pigmentation on the accuracy of oxygen saturation measurement by pulse oximetry (SpO(2)) compared with the gold standard SaO(2) measured by CO-oximetry. METHODS: We searched Ovid MEDLINE, Ovid Embase, EBSCO CINAHL, ClinicalTrials.gov, and WHO International Clinical Trials Registry Platform (up to December 2021) for studies with SpO(2)–SaO(2) comparisons and measuring the impact of skin pigmentation or ethnicity on pulse oximetry accuracy. We performed meta-analyses for mean bias (the primary outcome in this review) and its standard deviations (SDs) across studies included for each subgroup of skin pigmentation and ethnicity and used these pooled mean biases and SDs to calculate accuracy root-mean-square (A(rms)) and 95% limits of agreement. The review was registered with the Open Science Framework (https://osf.io/gm7ty). RESULTS: We included 32 studies (6505 participants): 15 measured skin pigmentation and 22 referred to ethnicity. Compared with standard SaO(2) measurement, pulse oximetry probably overestimates oxygen saturation in people with the high level of skin pigmentation (pooled mean bias 1.11%; 95% confidence interval 0.29 to 1.93%) and people described as Black/African American (1.52%; 0.95 to 2.09%) (moderate- and low-certainty evidence). The bias of pulse oximetry measurements for people with other levels of skin pigmentation or those from other ethnic groups is either more uncertain or suggests no overestimation. Whilst the extent of mean bias is small or negligible for all subgroups evaluated, the associated imprecision is unacceptably large (pooled SDs > 1%). When the extent of measurement bias and precision is considered jointly, pulse oximetry measurements for all the subgroups appear acceptably accurate (with A(rms) < 4%). CONCLUSIONS: Pulse oximetry may overestimate oxygen saturation in people with high levels of skin pigmentation and people whose ethnicity is reported as Black/African American, compared with SaO(2). The extent of overestimation may be small in hospital settings but unknown in community settings. REVIEW PROTOCOL REGISTRATION: https://osf.io/gm7ty SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s12916-022-02452-8. BioMed Central 2022-08-16 /pmc/articles/PMC9377806/ /pubmed/35971142 http://dx.doi.org/10.1186/s12916-022-02452-8 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Article Shi, Chunhu Goodall, Mark Dumville, Jo Hill, James Norman, Gill Hamer, Oliver Clegg, Andrew Watkins, Caroline Leigh Georgiou, George Hodkinson, Alexander Lightbody, Catherine Elizabeth Dark, Paul Cullum, Nicky The accuracy of pulse oximetry in measuring oxygen saturation by levels of skin pigmentation: a systematic review and meta-analysis |
title | The accuracy of pulse oximetry in measuring oxygen saturation by levels of skin pigmentation: a systematic review and meta-analysis |
title_full | The accuracy of pulse oximetry in measuring oxygen saturation by levels of skin pigmentation: a systematic review and meta-analysis |
title_fullStr | The accuracy of pulse oximetry in measuring oxygen saturation by levels of skin pigmentation: a systematic review and meta-analysis |
title_full_unstemmed | The accuracy of pulse oximetry in measuring oxygen saturation by levels of skin pigmentation: a systematic review and meta-analysis |
title_short | The accuracy of pulse oximetry in measuring oxygen saturation by levels of skin pigmentation: a systematic review and meta-analysis |
title_sort | accuracy of pulse oximetry in measuring oxygen saturation by levels of skin pigmentation: a systematic review and meta-analysis |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9377806/ https://www.ncbi.nlm.nih.gov/pubmed/35971142 http://dx.doi.org/10.1186/s12916-022-02452-8 |
work_keys_str_mv | AT shichunhu theaccuracyofpulseoximetryinmeasuringoxygensaturationbylevelsofskinpigmentationasystematicreviewandmetaanalysis AT goodallmark theaccuracyofpulseoximetryinmeasuringoxygensaturationbylevelsofskinpigmentationasystematicreviewandmetaanalysis AT dumvillejo theaccuracyofpulseoximetryinmeasuringoxygensaturationbylevelsofskinpigmentationasystematicreviewandmetaanalysis AT hilljames theaccuracyofpulseoximetryinmeasuringoxygensaturationbylevelsofskinpigmentationasystematicreviewandmetaanalysis AT normangill theaccuracyofpulseoximetryinmeasuringoxygensaturationbylevelsofskinpigmentationasystematicreviewandmetaanalysis AT hameroliver theaccuracyofpulseoximetryinmeasuringoxygensaturationbylevelsofskinpigmentationasystematicreviewandmetaanalysis AT cleggandrew theaccuracyofpulseoximetryinmeasuringoxygensaturationbylevelsofskinpigmentationasystematicreviewandmetaanalysis AT watkinscarolineleigh theaccuracyofpulseoximetryinmeasuringoxygensaturationbylevelsofskinpigmentationasystematicreviewandmetaanalysis AT georgiougeorge theaccuracyofpulseoximetryinmeasuringoxygensaturationbylevelsofskinpigmentationasystematicreviewandmetaanalysis AT hodkinsonalexander theaccuracyofpulseoximetryinmeasuringoxygensaturationbylevelsofskinpigmentationasystematicreviewandmetaanalysis AT lightbodycatherineelizabeth theaccuracyofpulseoximetryinmeasuringoxygensaturationbylevelsofskinpigmentationasystematicreviewandmetaanalysis AT darkpaul theaccuracyofpulseoximetryinmeasuringoxygensaturationbylevelsofskinpigmentationasystematicreviewandmetaanalysis AT cullumnicky theaccuracyofpulseoximetryinmeasuringoxygensaturationbylevelsofskinpigmentationasystematicreviewandmetaanalysis AT shichunhu accuracyofpulseoximetryinmeasuringoxygensaturationbylevelsofskinpigmentationasystematicreviewandmetaanalysis AT goodallmark accuracyofpulseoximetryinmeasuringoxygensaturationbylevelsofskinpigmentationasystematicreviewandmetaanalysis AT dumvillejo accuracyofpulseoximetryinmeasuringoxygensaturationbylevelsofskinpigmentationasystematicreviewandmetaanalysis AT hilljames accuracyofpulseoximetryinmeasuringoxygensaturationbylevelsofskinpigmentationasystematicreviewandmetaanalysis AT normangill accuracyofpulseoximetryinmeasuringoxygensaturationbylevelsofskinpigmentationasystematicreviewandmetaanalysis AT hameroliver accuracyofpulseoximetryinmeasuringoxygensaturationbylevelsofskinpigmentationasystematicreviewandmetaanalysis AT cleggandrew accuracyofpulseoximetryinmeasuringoxygensaturationbylevelsofskinpigmentationasystematicreviewandmetaanalysis AT watkinscarolineleigh accuracyofpulseoximetryinmeasuringoxygensaturationbylevelsofskinpigmentationasystematicreviewandmetaanalysis AT georgiougeorge accuracyofpulseoximetryinmeasuringoxygensaturationbylevelsofskinpigmentationasystematicreviewandmetaanalysis AT hodkinsonalexander accuracyofpulseoximetryinmeasuringoxygensaturationbylevelsofskinpigmentationasystematicreviewandmetaanalysis AT lightbodycatherineelizabeth accuracyofpulseoximetryinmeasuringoxygensaturationbylevelsofskinpigmentationasystematicreviewandmetaanalysis AT darkpaul accuracyofpulseoximetryinmeasuringoxygensaturationbylevelsofskinpigmentationasystematicreviewandmetaanalysis AT cullumnicky accuracyofpulseoximetryinmeasuringoxygensaturationbylevelsofskinpigmentationasystematicreviewandmetaanalysis |