Cargando…

Procedural Efficiency, Efficacy, and Safety of High-Power, Short-Duration Radiofrequency Ablation Delivered by STSF Catheter for Paroxysmal Atrial Fibrillation

OBJECTIVES: To investigate the procedural efficiency, efficacy, and safety of high-power, short-term radiofrequency ablation delivered by the SmartTouch Surround Flow (STSF) catheter for paroxysmal atrial fibrillation (AF). METHODS: We retrospectively analyzed a total of 72 patients who were admitte...

Descripción completa

Detalles Bibliográficos
Autores principales: Cheng, Cheng, Xu, Banglong, Sheng, Jianlong, Huang, Zheng, He, Fei, Gao, Feng, Wang, Xiaochen
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9377865/
https://www.ncbi.nlm.nih.gov/pubmed/35979002
http://dx.doi.org/10.1155/2022/6009275
Descripción
Sumario:OBJECTIVES: To investigate the procedural efficiency, efficacy, and safety of high-power, short-term radiofrequency ablation delivered by the SmartTouch Surround Flow (STSF) catheter for paroxysmal atrial fibrillation (AF). METHODS: We retrospectively analyzed a total of 72 patients who were admitted with paroxysmal AF, and who underwent radiofrequency catheter ablation (RFCA) for the first time. Of these patients, 36 cases underwent low-power, long-duration (LPLD, (30–35 W/20–40 s) pulmonary vein isolation (PVI) delivered by an SmartTouch (ST) catheter (control group), and the other 36 cases underwent high-power, short-duration (HPSD, (45–50 W/10–20 s) PVI delivered by a STSF catheter (study group). The baseline data, duration of PVI, procedural time, fluoroscopy time, the rate of first-pass isolation, irrigation perfusion, eschar and steam pop occurrences, intraoperative complications, and the rate of stable sinus rhythm maintenance following a blanking period of three months were analyzed between the two groups. RESULTS: The isolation time of bilateral PVI and procedural time in the study group were markedly less than in controls (p < 0.01). The rate of first-pass isolation in the study group was significantly higher than in the control group (95.8% vs. 84.7%, p = 0.023), while the fluid perfusion in the study group was approximately 20% less than that in the control group (767 ± 171 vs. 966 ± 227 ml, p < 0.001). We observed no severe complications in any patients. The rate of freedom from AF recurrences following a blanking period of three months showed a tendency to be higher than in controls (93.9% vs. 87.1%, p = 0.348). CONCLUSIONS: The HPSD strategy delivered by the STSF catheter was superior to conventional LPLD ablation through the ST catheter with respect to efficiency, acute procedural effectiveness, short-term safety, and the risk of heart failure in patients with paroxysmal AF.