Cargando…

Procedural Efficiency, Efficacy, and Safety of High-Power, Short-Duration Radiofrequency Ablation Delivered by STSF Catheter for Paroxysmal Atrial Fibrillation

OBJECTIVES: To investigate the procedural efficiency, efficacy, and safety of high-power, short-term radiofrequency ablation delivered by the SmartTouch Surround Flow (STSF) catheter for paroxysmal atrial fibrillation (AF). METHODS: We retrospectively analyzed a total of 72 patients who were admitte...

Descripción completa

Detalles Bibliográficos
Autores principales: Cheng, Cheng, Xu, Banglong, Sheng, Jianlong, Huang, Zheng, He, Fei, Gao, Feng, Wang, Xiaochen
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9377865/
https://www.ncbi.nlm.nih.gov/pubmed/35979002
http://dx.doi.org/10.1155/2022/6009275
_version_ 1784768422668664832
author Cheng, Cheng
Xu, Banglong
Sheng, Jianlong
Huang, Zheng
He, Fei
Gao, Feng
Wang, Xiaochen
author_facet Cheng, Cheng
Xu, Banglong
Sheng, Jianlong
Huang, Zheng
He, Fei
Gao, Feng
Wang, Xiaochen
author_sort Cheng, Cheng
collection PubMed
description OBJECTIVES: To investigate the procedural efficiency, efficacy, and safety of high-power, short-term radiofrequency ablation delivered by the SmartTouch Surround Flow (STSF) catheter for paroxysmal atrial fibrillation (AF). METHODS: We retrospectively analyzed a total of 72 patients who were admitted with paroxysmal AF, and who underwent radiofrequency catheter ablation (RFCA) for the first time. Of these patients, 36 cases underwent low-power, long-duration (LPLD, (30–35 W/20–40 s) pulmonary vein isolation (PVI) delivered by an SmartTouch (ST) catheter (control group), and the other 36 cases underwent high-power, short-duration (HPSD, (45–50 W/10–20 s) PVI delivered by a STSF catheter (study group). The baseline data, duration of PVI, procedural time, fluoroscopy time, the rate of first-pass isolation, irrigation perfusion, eschar and steam pop occurrences, intraoperative complications, and the rate of stable sinus rhythm maintenance following a blanking period of three months were analyzed between the two groups. RESULTS: The isolation time of bilateral PVI and procedural time in the study group were markedly less than in controls (p < 0.01). The rate of first-pass isolation in the study group was significantly higher than in the control group (95.8% vs. 84.7%, p = 0.023), while the fluid perfusion in the study group was approximately 20% less than that in the control group (767 ± 171 vs. 966 ± 227 ml, p < 0.001). We observed no severe complications in any patients. The rate of freedom from AF recurrences following a blanking period of three months showed a tendency to be higher than in controls (93.9% vs. 87.1%, p = 0.348). CONCLUSIONS: The HPSD strategy delivered by the STSF catheter was superior to conventional LPLD ablation through the ST catheter with respect to efficiency, acute procedural effectiveness, short-term safety, and the risk of heart failure in patients with paroxysmal AF.
format Online
Article
Text
id pubmed-9377865
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-93778652022-08-16 Procedural Efficiency, Efficacy, and Safety of High-Power, Short-Duration Radiofrequency Ablation Delivered by STSF Catheter for Paroxysmal Atrial Fibrillation Cheng, Cheng Xu, Banglong Sheng, Jianlong Huang, Zheng He, Fei Gao, Feng Wang, Xiaochen Evid Based Complement Alternat Med Research Article OBJECTIVES: To investigate the procedural efficiency, efficacy, and safety of high-power, short-term radiofrequency ablation delivered by the SmartTouch Surround Flow (STSF) catheter for paroxysmal atrial fibrillation (AF). METHODS: We retrospectively analyzed a total of 72 patients who were admitted with paroxysmal AF, and who underwent radiofrequency catheter ablation (RFCA) for the first time. Of these patients, 36 cases underwent low-power, long-duration (LPLD, (30–35 W/20–40 s) pulmonary vein isolation (PVI) delivered by an SmartTouch (ST) catheter (control group), and the other 36 cases underwent high-power, short-duration (HPSD, (45–50 W/10–20 s) PVI delivered by a STSF catheter (study group). The baseline data, duration of PVI, procedural time, fluoroscopy time, the rate of first-pass isolation, irrigation perfusion, eschar and steam pop occurrences, intraoperative complications, and the rate of stable sinus rhythm maintenance following a blanking period of three months were analyzed between the two groups. RESULTS: The isolation time of bilateral PVI and procedural time in the study group were markedly less than in controls (p < 0.01). The rate of first-pass isolation in the study group was significantly higher than in the control group (95.8% vs. 84.7%, p = 0.023), while the fluid perfusion in the study group was approximately 20% less than that in the control group (767 ± 171 vs. 966 ± 227 ml, p < 0.001). We observed no severe complications in any patients. The rate of freedom from AF recurrences following a blanking period of three months showed a tendency to be higher than in controls (93.9% vs. 87.1%, p = 0.348). CONCLUSIONS: The HPSD strategy delivered by the STSF catheter was superior to conventional LPLD ablation through the ST catheter with respect to efficiency, acute procedural effectiveness, short-term safety, and the risk of heart failure in patients with paroxysmal AF. Hindawi 2022-08-08 /pmc/articles/PMC9377865/ /pubmed/35979002 http://dx.doi.org/10.1155/2022/6009275 Text en Copyright © 2022 Cheng Cheng et al. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Cheng, Cheng
Xu, Banglong
Sheng, Jianlong
Huang, Zheng
He, Fei
Gao, Feng
Wang, Xiaochen
Procedural Efficiency, Efficacy, and Safety of High-Power, Short-Duration Radiofrequency Ablation Delivered by STSF Catheter for Paroxysmal Atrial Fibrillation
title Procedural Efficiency, Efficacy, and Safety of High-Power, Short-Duration Radiofrequency Ablation Delivered by STSF Catheter for Paroxysmal Atrial Fibrillation
title_full Procedural Efficiency, Efficacy, and Safety of High-Power, Short-Duration Radiofrequency Ablation Delivered by STSF Catheter for Paroxysmal Atrial Fibrillation
title_fullStr Procedural Efficiency, Efficacy, and Safety of High-Power, Short-Duration Radiofrequency Ablation Delivered by STSF Catheter for Paroxysmal Atrial Fibrillation
title_full_unstemmed Procedural Efficiency, Efficacy, and Safety of High-Power, Short-Duration Radiofrequency Ablation Delivered by STSF Catheter for Paroxysmal Atrial Fibrillation
title_short Procedural Efficiency, Efficacy, and Safety of High-Power, Short-Duration Radiofrequency Ablation Delivered by STSF Catheter for Paroxysmal Atrial Fibrillation
title_sort procedural efficiency, efficacy, and safety of high-power, short-duration radiofrequency ablation delivered by stsf catheter for paroxysmal atrial fibrillation
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9377865/
https://www.ncbi.nlm.nih.gov/pubmed/35979002
http://dx.doi.org/10.1155/2022/6009275
work_keys_str_mv AT chengcheng proceduralefficiencyefficacyandsafetyofhighpowershortdurationradiofrequencyablationdeliveredbystsfcatheterforparoxysmalatrialfibrillation
AT xubanglong proceduralefficiencyefficacyandsafetyofhighpowershortdurationradiofrequencyablationdeliveredbystsfcatheterforparoxysmalatrialfibrillation
AT shengjianlong proceduralefficiencyefficacyandsafetyofhighpowershortdurationradiofrequencyablationdeliveredbystsfcatheterforparoxysmalatrialfibrillation
AT huangzheng proceduralefficiencyefficacyandsafetyofhighpowershortdurationradiofrequencyablationdeliveredbystsfcatheterforparoxysmalatrialfibrillation
AT hefei proceduralefficiencyefficacyandsafetyofhighpowershortdurationradiofrequencyablationdeliveredbystsfcatheterforparoxysmalatrialfibrillation
AT gaofeng proceduralefficiencyefficacyandsafetyofhighpowershortdurationradiofrequencyablationdeliveredbystsfcatheterforparoxysmalatrialfibrillation
AT wangxiaochen proceduralefficiencyefficacyandsafetyofhighpowershortdurationradiofrequencyablationdeliveredbystsfcatheterforparoxysmalatrialfibrillation