The Utility and Acceptability of a New Noninvasive Ventilatory Assist Device, Rest-Activity Cycler-Positive Airways Pressure, During Exercise in a Population of Healthy Adults: Cohort Study

BACKGROUND: Noninvasive ventilation has been demonstrated to benefit people who have moderate to severe chronic obstructive pulmonary disease during acute exacerbations. Studies have begun to investigate the effectiveness of noninvasive ventilation during pulmonary rehabilitation to improve outcomes...

Descripción completa

Detalles Bibliográficos
Autores principales: Reeve, Julie, Mooney, Sarah, Jepsen, Nicola, White, David
Formato: Online Artículo Texto
Lenguaje:English
Publicado: JMIR Publications 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9379794/
https://www.ncbi.nlm.nih.gov/pubmed/35916705
http://dx.doi.org/10.2196/35494
_version_ 1784768749954400256
author Reeve, Julie
Mooney, Sarah
Jepsen, Nicola
White, David
author_facet Reeve, Julie
Mooney, Sarah
Jepsen, Nicola
White, David
author_sort Reeve, Julie
collection PubMed
description BACKGROUND: Noninvasive ventilation has been demonstrated to benefit people who have moderate to severe chronic obstructive pulmonary disease during acute exacerbations. Studies have begun to investigate the effectiveness of noninvasive ventilation during pulmonary rehabilitation to improve outcomes for people with chronic obstructive pulmonary disease; however, the lack of portability and humidification of these devices means their use is limited, especially when performing activities of daily living. A new prototype device, RACer-PAP (rest-activity cycler-positive airways pressure), delivers battery-operated positive airway pressure via a nasal interface while regulating nasal airway apportionment bias, removing the need for supplementary humidification. This device may offer people with chronic obstructive pulmonary disease an improved ability to participate in pulmonary rehabilitation and activities of daily living. OBJECTIVE: To assess the feasibility of exercising with the RACer-PAP in situ and the acceptability of the device during exercise in normal, healthy individuals. METHODS: A total of 15 healthy adults were invited to attend 2 exercise sessions, each 1 week apart. Sessions lasted approximately 1 hour and included 2 baseline 6-minute walk distance assessments, once with and once without the RACer-PAP in situ. Vital signs and spirometry results were monitored throughout, and spirometry was performed pre- and posttesting with RACer-PAP. Subjective questionnaires ascertained participant feedback on exercising with the device in situ. RESULTS: Of the 15 initial participants, 14 (93%) completed both sessions. There were no adverse events associated with exercising with the device in situ. There were no differences in vital signs or 6-minute walk distance whether exercising with or without the device in situ. There were small increases in maximum dyspnea score (on the Borg scale) when exercising with the device in situ (median score 2.0, IQR 0.5-3.0, vs 3.0, IQR 2.0-3.25). There were small increases in forced vital capacity following exercise with the RACer-PAP. None of the participants reported symptoms associated with airway drying. Participant feedback provided recommendations for modifications for the next iteration of the device prior to piloting the device with people with chronic obstructive pulmonary disease. CONCLUSIONS: This study has shown RACer-PAP to be safe and feasible to use during exercise and has provided feedback for modifications to the device to improve its use during exercise. We now propose to consider the application of the device in a small pilot feasibility study to assess the safety, feasibility, and utility of the device in a population of people with moderate to severe chronic obstructive pulmonary disease. TRIAL REGISTRATION: Australian New Zealand Clinical Trials Registry ACTRN12619000478112; https://www.anzctr.org.au/Trial/Registration/TrialReview.aspx?id=375477
format Online
Article
Text
id pubmed-9379794
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher JMIR Publications
record_format MEDLINE/PubMed
spelling pubmed-93797942022-08-17 The Utility and Acceptability of a New Noninvasive Ventilatory Assist Device, Rest-Activity Cycler-Positive Airways Pressure, During Exercise in a Population of Healthy Adults: Cohort Study Reeve, Julie Mooney, Sarah Jepsen, Nicola White, David JMIR Rehabil Assist Technol Original Paper BACKGROUND: Noninvasive ventilation has been demonstrated to benefit people who have moderate to severe chronic obstructive pulmonary disease during acute exacerbations. Studies have begun to investigate the effectiveness of noninvasive ventilation during pulmonary rehabilitation to improve outcomes for people with chronic obstructive pulmonary disease; however, the lack of portability and humidification of these devices means their use is limited, especially when performing activities of daily living. A new prototype device, RACer-PAP (rest-activity cycler-positive airways pressure), delivers battery-operated positive airway pressure via a nasal interface while regulating nasal airway apportionment bias, removing the need for supplementary humidification. This device may offer people with chronic obstructive pulmonary disease an improved ability to participate in pulmonary rehabilitation and activities of daily living. OBJECTIVE: To assess the feasibility of exercising with the RACer-PAP in situ and the acceptability of the device during exercise in normal, healthy individuals. METHODS: A total of 15 healthy adults were invited to attend 2 exercise sessions, each 1 week apart. Sessions lasted approximately 1 hour and included 2 baseline 6-minute walk distance assessments, once with and once without the RACer-PAP in situ. Vital signs and spirometry results were monitored throughout, and spirometry was performed pre- and posttesting with RACer-PAP. Subjective questionnaires ascertained participant feedback on exercising with the device in situ. RESULTS: Of the 15 initial participants, 14 (93%) completed both sessions. There were no adverse events associated with exercising with the device in situ. There were no differences in vital signs or 6-minute walk distance whether exercising with or without the device in situ. There were small increases in maximum dyspnea score (on the Borg scale) when exercising with the device in situ (median score 2.0, IQR 0.5-3.0, vs 3.0, IQR 2.0-3.25). There were small increases in forced vital capacity following exercise with the RACer-PAP. None of the participants reported symptoms associated with airway drying. Participant feedback provided recommendations for modifications for the next iteration of the device prior to piloting the device with people with chronic obstructive pulmonary disease. CONCLUSIONS: This study has shown RACer-PAP to be safe and feasible to use during exercise and has provided feedback for modifications to the device to improve its use during exercise. We now propose to consider the application of the device in a small pilot feasibility study to assess the safety, feasibility, and utility of the device in a population of people with moderate to severe chronic obstructive pulmonary disease. TRIAL REGISTRATION: Australian New Zealand Clinical Trials Registry ACTRN12619000478112; https://www.anzctr.org.au/Trial/Registration/TrialReview.aspx?id=375477 JMIR Publications 2022-08-01 /pmc/articles/PMC9379794/ /pubmed/35916705 http://dx.doi.org/10.2196/35494 Text en ©Julie Reeve, Sarah Mooney, Nicola Jepsen, David White. Originally published in JMIR Rehabilitation and Assistive Technology (https://rehab.jmir.org), 01.08.2022. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work, first published in JMIR Rehabilitation and Assistive Technology, is properly cited. The complete bibliographic information, a link to the original publication on https://rehab.jmir.org/, as well as this copyright and license information must be included.
spellingShingle Original Paper
Reeve, Julie
Mooney, Sarah
Jepsen, Nicola
White, David
The Utility and Acceptability of a New Noninvasive Ventilatory Assist Device, Rest-Activity Cycler-Positive Airways Pressure, During Exercise in a Population of Healthy Adults: Cohort Study
title The Utility and Acceptability of a New Noninvasive Ventilatory Assist Device, Rest-Activity Cycler-Positive Airways Pressure, During Exercise in a Population of Healthy Adults: Cohort Study
title_full The Utility and Acceptability of a New Noninvasive Ventilatory Assist Device, Rest-Activity Cycler-Positive Airways Pressure, During Exercise in a Population of Healthy Adults: Cohort Study
title_fullStr The Utility and Acceptability of a New Noninvasive Ventilatory Assist Device, Rest-Activity Cycler-Positive Airways Pressure, During Exercise in a Population of Healthy Adults: Cohort Study
title_full_unstemmed The Utility and Acceptability of a New Noninvasive Ventilatory Assist Device, Rest-Activity Cycler-Positive Airways Pressure, During Exercise in a Population of Healthy Adults: Cohort Study
title_short The Utility and Acceptability of a New Noninvasive Ventilatory Assist Device, Rest-Activity Cycler-Positive Airways Pressure, During Exercise in a Population of Healthy Adults: Cohort Study
title_sort utility and acceptability of a new noninvasive ventilatory assist device, rest-activity cycler-positive airways pressure, during exercise in a population of healthy adults: cohort study
topic Original Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9379794/
https://www.ncbi.nlm.nih.gov/pubmed/35916705
http://dx.doi.org/10.2196/35494
work_keys_str_mv AT reevejulie theutilityandacceptabilityofanewnoninvasiveventilatoryassistdevicerestactivitycyclerpositiveairwayspressureduringexerciseinapopulationofhealthyadultscohortstudy
AT mooneysarah theutilityandacceptabilityofanewnoninvasiveventilatoryassistdevicerestactivitycyclerpositiveairwayspressureduringexerciseinapopulationofhealthyadultscohortstudy
AT jepsennicola theutilityandacceptabilityofanewnoninvasiveventilatoryassistdevicerestactivitycyclerpositiveairwayspressureduringexerciseinapopulationofhealthyadultscohortstudy
AT whitedavid theutilityandacceptabilityofanewnoninvasiveventilatoryassistdevicerestactivitycyclerpositiveairwayspressureduringexerciseinapopulationofhealthyadultscohortstudy
AT reevejulie utilityandacceptabilityofanewnoninvasiveventilatoryassistdevicerestactivitycyclerpositiveairwayspressureduringexerciseinapopulationofhealthyadultscohortstudy
AT mooneysarah utilityandacceptabilityofanewnoninvasiveventilatoryassistdevicerestactivitycyclerpositiveairwayspressureduringexerciseinapopulationofhealthyadultscohortstudy
AT jepsennicola utilityandacceptabilityofanewnoninvasiveventilatoryassistdevicerestactivitycyclerpositiveairwayspressureduringexerciseinapopulationofhealthyadultscohortstudy
AT whitedavid utilityandacceptabilityofanewnoninvasiveventilatoryassistdevicerestactivitycyclerpositiveairwayspressureduringexerciseinapopulationofhealthyadultscohortstudy