Impact of signal-averaged electrocardiography findings on appropriate shocks in prophylactic implantable cardioverter defibrillator patients with nonischemic systolic heart failure
BACKGROUND: Appropriate shock therapy is associated with subsequent all-cause death in heart failure (HF) patients who receive an implantable cardioverter defibrillator (ICD) for the primary prevention of sudden cardiac death. To evaluate the impact of signal-averaged electrocardiography (SAECG) fin...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9382808/ https://www.ncbi.nlm.nih.gov/pubmed/35974317 http://dx.doi.org/10.1186/s12872-022-02811-6 |
_version_ | 1784769360917692416 |
---|---|
author | Nomoto, Michiru Suzuki, Atsushi Shiga, Tsuyoshi Shoda, Morio Hagiwara, Nobuhisa |
author_facet | Nomoto, Michiru Suzuki, Atsushi Shiga, Tsuyoshi Shoda, Morio Hagiwara, Nobuhisa |
author_sort | Nomoto, Michiru |
collection | PubMed |
description | BACKGROUND: Appropriate shock therapy is associated with subsequent all-cause death in heart failure (HF) patients who receive an implantable cardioverter defibrillator (ICD) for the primary prevention of sudden cardiac death. To evaluate the impact of signal-averaged electrocardiography (SAECG) findings on appropriate shocks in prophylactic ICD patients with nonischemic systolic HF. METHODS: We studied 86 patients with nonischemic HF and a left ventricular ejection fraction ≤ 35% who underwent new ICD implantation for the primary prevention of sudden cardiac death. We excluded patients who had a previously implanted permanent pacemaker and patients who received cardiac resynchronization therapy with an ICD. SAECG was performed before implantation. Abnormal SAECG findings were defined if 2 of the following 3 conditions were identified: filtered QRS duration (fQRS) ≥ 114 ms, root-mean-square voltage during the last 40 ms of the fQRS (RMS 40) < 20 μV, and duration of the low-amplitude potentials < 40 μV (LAS 40) > 38 ms; additionally, patients with a QRS complex ≥ 120 ms who met both the RMS 40 and LAS 40 criteria were also considered to have abnormal SAECG findings. The primary outcome was the first occurrence of appropriate shock after implantation of the ICD. The secondary outcomes were the first occurrence of inappropriate shock and all-cause mortality. RESULTS: Forty-two patients met the criteria for abnormal SAECG findings (49%). During a median follow-up period of 61 months, 17 patients (20%) died, 24 (28%) received appropriate shock therapy, and 19 (22%) received inappropriate shock therapy. There was a significantly higher incidence of appropriate shocks in patients with abnormal SAECG findings than in those with normal SAECG findings (log-rank test, p = 0.025). Multivariate analysis revealed that abnormal SAECG findings were independently associated with the occurrence of appropriate shock (hazard ratio 2.67, 95% confidential interval 1.14–6.26). However, abnormal SAECG findings were not related to inappropriate shock. There was no difference in the incidence of all-cause death between patients with abnormal and normal SAECG findings. CONCLUSIONS: Our results suggest that abnormal SAECG findings are associated with a high probability of appropriate shocks in prophylactic ICD patients with nonischemic systolic HF. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s12872-022-02811-6. |
format | Online Article Text |
id | pubmed-9382808 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-93828082022-08-18 Impact of signal-averaged electrocardiography findings on appropriate shocks in prophylactic implantable cardioverter defibrillator patients with nonischemic systolic heart failure Nomoto, Michiru Suzuki, Atsushi Shiga, Tsuyoshi Shoda, Morio Hagiwara, Nobuhisa BMC Cardiovasc Disord Research BACKGROUND: Appropriate shock therapy is associated with subsequent all-cause death in heart failure (HF) patients who receive an implantable cardioverter defibrillator (ICD) for the primary prevention of sudden cardiac death. To evaluate the impact of signal-averaged electrocardiography (SAECG) findings on appropriate shocks in prophylactic ICD patients with nonischemic systolic HF. METHODS: We studied 86 patients with nonischemic HF and a left ventricular ejection fraction ≤ 35% who underwent new ICD implantation for the primary prevention of sudden cardiac death. We excluded patients who had a previously implanted permanent pacemaker and patients who received cardiac resynchronization therapy with an ICD. SAECG was performed before implantation. Abnormal SAECG findings were defined if 2 of the following 3 conditions were identified: filtered QRS duration (fQRS) ≥ 114 ms, root-mean-square voltage during the last 40 ms of the fQRS (RMS 40) < 20 μV, and duration of the low-amplitude potentials < 40 μV (LAS 40) > 38 ms; additionally, patients with a QRS complex ≥ 120 ms who met both the RMS 40 and LAS 40 criteria were also considered to have abnormal SAECG findings. The primary outcome was the first occurrence of appropriate shock after implantation of the ICD. The secondary outcomes were the first occurrence of inappropriate shock and all-cause mortality. RESULTS: Forty-two patients met the criteria for abnormal SAECG findings (49%). During a median follow-up period of 61 months, 17 patients (20%) died, 24 (28%) received appropriate shock therapy, and 19 (22%) received inappropriate shock therapy. There was a significantly higher incidence of appropriate shocks in patients with abnormal SAECG findings than in those with normal SAECG findings (log-rank test, p = 0.025). Multivariate analysis revealed that abnormal SAECG findings were independently associated with the occurrence of appropriate shock (hazard ratio 2.67, 95% confidential interval 1.14–6.26). However, abnormal SAECG findings were not related to inappropriate shock. There was no difference in the incidence of all-cause death between patients with abnormal and normal SAECG findings. CONCLUSIONS: Our results suggest that abnormal SAECG findings are associated with a high probability of appropriate shocks in prophylactic ICD patients with nonischemic systolic HF. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s12872-022-02811-6. BioMed Central 2022-08-16 /pmc/articles/PMC9382808/ /pubmed/35974317 http://dx.doi.org/10.1186/s12872-022-02811-6 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Nomoto, Michiru Suzuki, Atsushi Shiga, Tsuyoshi Shoda, Morio Hagiwara, Nobuhisa Impact of signal-averaged electrocardiography findings on appropriate shocks in prophylactic implantable cardioverter defibrillator patients with nonischemic systolic heart failure |
title | Impact of signal-averaged electrocardiography findings on appropriate shocks in prophylactic implantable cardioverter defibrillator patients with nonischemic systolic heart failure |
title_full | Impact of signal-averaged electrocardiography findings on appropriate shocks in prophylactic implantable cardioverter defibrillator patients with nonischemic systolic heart failure |
title_fullStr | Impact of signal-averaged electrocardiography findings on appropriate shocks in prophylactic implantable cardioverter defibrillator patients with nonischemic systolic heart failure |
title_full_unstemmed | Impact of signal-averaged electrocardiography findings on appropriate shocks in prophylactic implantable cardioverter defibrillator patients with nonischemic systolic heart failure |
title_short | Impact of signal-averaged electrocardiography findings on appropriate shocks in prophylactic implantable cardioverter defibrillator patients with nonischemic systolic heart failure |
title_sort | impact of signal-averaged electrocardiography findings on appropriate shocks in prophylactic implantable cardioverter defibrillator patients with nonischemic systolic heart failure |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9382808/ https://www.ncbi.nlm.nih.gov/pubmed/35974317 http://dx.doi.org/10.1186/s12872-022-02811-6 |
work_keys_str_mv | AT nomotomichiru impactofsignalaveragedelectrocardiographyfindingsonappropriateshocksinprophylacticimplantablecardioverterdefibrillatorpatientswithnonischemicsystolicheartfailure AT suzukiatsushi impactofsignalaveragedelectrocardiographyfindingsonappropriateshocksinprophylacticimplantablecardioverterdefibrillatorpatientswithnonischemicsystolicheartfailure AT shigatsuyoshi impactofsignalaveragedelectrocardiographyfindingsonappropriateshocksinprophylacticimplantablecardioverterdefibrillatorpatientswithnonischemicsystolicheartfailure AT shodamorio impactofsignalaveragedelectrocardiographyfindingsonappropriateshocksinprophylacticimplantablecardioverterdefibrillatorpatientswithnonischemicsystolicheartfailure AT hagiwaranobuhisa impactofsignalaveragedelectrocardiographyfindingsonappropriateshocksinprophylacticimplantablecardioverterdefibrillatorpatientswithnonischemicsystolicheartfailure |