Cargando…

Design of Wearable Hand Rehabilitation Glove With Bionic Fiber-Reinforced Actuator

Background: The hand motor function is lost and activities in daily life (ADLs) are affected due to some illnesses such as stroke and hemiplegia. As a coping way, we present a wearable rehabilitation glove with the bionic actuator for restoring the hand function and the motor control ability lost by...

Descripción completa

Detalles Bibliográficos
Formato: Online Artículo Texto
Lenguaje:English
Publicado: IEEE 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9384960/
https://www.ncbi.nlm.nih.gov/pubmed/35992370
http://dx.doi.org/10.1109/JTEHM.2022.3196491
_version_ 1784769492160610304
collection PubMed
description Background: The hand motor function is lost and activities in daily life (ADLs) are affected due to some illnesses such as stroke and hemiplegia. As a coping way, we present a wearable rehabilitation glove with the bionic actuator for restoring the hand function and the motor control ability lost by stroke patients. Methods: The soft pneumatic bionic actuator (SPBA) is developed on the basis of the research of human hand bone structure and finger joint characteristics and a series of tests are conducted. Besides, we built the rehabilitation glove system based on the proposed SPBAs to verify the availability due to typical gesture, mirror therapy (MT) and grasping experiment for irregular objects. Result: The bending angle of SPBA can reach 260°. The output force of it can reach 5.1N with 0.25 MPa air pressure input. The maximum variance of the bending angle can be concluded at 5.1° in MT. The grasping experiments of the glove worn on the hand or not shows the proposed glove is flexible, the grip force is large and achieve stable grasping of objects. Conclusion: The designed SPBA is satisfied with the requirements of rehabilitation training and the proposed glove restore the normal hand motion of patients in ADLs.
format Online
Article
Text
id pubmed-9384960
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher IEEE
record_format MEDLINE/PubMed
spelling pubmed-93849602022-08-18 Design of Wearable Hand Rehabilitation Glove With Bionic Fiber-Reinforced Actuator IEEE J Transl Eng Health Med Article Background: The hand motor function is lost and activities in daily life (ADLs) are affected due to some illnesses such as stroke and hemiplegia. As a coping way, we present a wearable rehabilitation glove with the bionic actuator for restoring the hand function and the motor control ability lost by stroke patients. Methods: The soft pneumatic bionic actuator (SPBA) is developed on the basis of the research of human hand bone structure and finger joint characteristics and a series of tests are conducted. Besides, we built the rehabilitation glove system based on the proposed SPBAs to verify the availability due to typical gesture, mirror therapy (MT) and grasping experiment for irregular objects. Result: The bending angle of SPBA can reach 260°. The output force of it can reach 5.1N with 0.25 MPa air pressure input. The maximum variance of the bending angle can be concluded at 5.1° in MT. The grasping experiments of the glove worn on the hand or not shows the proposed glove is flexible, the grip force is large and achieve stable grasping of objects. Conclusion: The designed SPBA is satisfied with the requirements of rehabilitation training and the proposed glove restore the normal hand motion of patients in ADLs. IEEE 2022-08-04 /pmc/articles/PMC9384960/ /pubmed/35992370 http://dx.doi.org/10.1109/JTEHM.2022.3196491 Text en https://creativecommons.org/licenses/by-nc-nd/4.0/This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 License. For more information, see https://creativecommons.org/licenses/by-nc-nd/4.0/
spellingShingle Article
Design of Wearable Hand Rehabilitation Glove With Bionic Fiber-Reinforced Actuator
title Design of Wearable Hand Rehabilitation Glove With Bionic Fiber-Reinforced Actuator
title_full Design of Wearable Hand Rehabilitation Glove With Bionic Fiber-Reinforced Actuator
title_fullStr Design of Wearable Hand Rehabilitation Glove With Bionic Fiber-Reinforced Actuator
title_full_unstemmed Design of Wearable Hand Rehabilitation Glove With Bionic Fiber-Reinforced Actuator
title_short Design of Wearable Hand Rehabilitation Glove With Bionic Fiber-Reinforced Actuator
title_sort design of wearable hand rehabilitation glove with bionic fiber-reinforced actuator
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9384960/
https://www.ncbi.nlm.nih.gov/pubmed/35992370
http://dx.doi.org/10.1109/JTEHM.2022.3196491
work_keys_str_mv AT designofwearablehandrehabilitationglovewithbionicfiberreinforcedactuator
AT designofwearablehandrehabilitationglovewithbionicfiberreinforcedactuator
AT designofwearablehandrehabilitationglovewithbionicfiberreinforcedactuator