PURPOSE: The purpose of this retrospective pilot study was to examine the short-term effect of simultaneous Ahmed Glaucoma Valve implantation and cyclophotocoagulation on postoperative outcomes in patients with neovascular glaucoma. METHODS AND MATERIALS: Patient charts were selected for inclusion i...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Jaypee Brothers Medical Publishers
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9385394/ https://www.ncbi.nlm.nih.gov/pubmed/36060048 http://dx.doi.org/10.5005/jp-journals-10078-1358 |
Sumario: | PURPOSE: The purpose of this retrospective pilot study was to examine the short-term effect of simultaneous Ahmed Glaucoma Valve implantation and cyclophotocoagulation on postoperative outcomes in patients with neovascular glaucoma. METHODS AND MATERIALS: Patient charts were selected for inclusion in this study if they carried a diagnosis of neovascular glaucoma and underwent Ahmed glaucoma valve implantation only, Ahmed glaucoma valve implantation with cyclophotocoagulation, or cyclophotocoagulation only. A total of 55 eyes of 54 patients were selected for data collection and analysis. Main outcome measures included 1-, 3-, and 6-month intraocular pressure and occurrence of the hypertensive phase. Other outcomes included visual acuity, surgical complication rate, and a number of 6-month postoperative ophthalmic medications. RESULTS: A significantly lower intraocular pressure was seen in the group that received Ahmed glaucoma valve implantation + cyclophotocoagulation compared to the Ahmed glaucoma valve-only group at 3 and 6 months (p = 0.03 and <0.001, respectively). The difference in the occurrence of the hypertensive phase between the Ahmed glaucoma valve-only group and the Ahmed glaucoma valve + cyclophotocoagulation group approached but did not reach significance (p = 0.052). A significantly lower intraocular pressure was also seen in the cyclophotocoagulation-only group compared to the Ahmed glaucoma valve-only group at 3 months (p = 0.006). CONCLUSION: Simultaneous Ahmed glaucoma valve implantation and cyclophotocoagulation significantly lowered intraocular pressure at 3 and 6 months compared to Ahmed glaucoma valve implantation alone in patients with neovascular glaucoma. CLINICAL SIGNIFICANCE: Neovascular glaucoma is difficult to manage medically and surgically. When surgery is performed, intraocular pressure often remains elevated postoperatively despite aggressive medical management. This study examines a novel method to lower intraocular pressure after Ahmed glaucoma valve implantation in patients with neovascular glaucoma. HOW TO CITE THIS ARTICLE: Ford RL, Knight ORJ, Klifto MR, et al. A Pilot Study Assessing Treatment Outcomes in Neovascular Glaucoma Using Ahmed Glaucoma Valve with and without Cyclophotocoagulation. J Curr Glaucoma Pract 2022;16(1):4-10. |
---|