Cargando…
A predictive model of macrosomic birth based upon real-world clinical data from pregnant women
BACKGROUND: Fetal macrosomia is associated with an increased risk of several maternal and newborn complications. Antenatal predication of fetal macrosomia remains challenging. We aimed to develop a nomogram model for the prediction of macrosomia using real-world clinical data to improve the sensitiv...
Autores principales: | , , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9386989/ https://www.ncbi.nlm.nih.gov/pubmed/35982421 http://dx.doi.org/10.1186/s12884-022-04981-9 |
Sumario: | BACKGROUND: Fetal macrosomia is associated with an increased risk of several maternal and newborn complications. Antenatal predication of fetal macrosomia remains challenging. We aimed to develop a nomogram model for the prediction of macrosomia using real-world clinical data to improve the sensitivity and specificity of macrosomia prediction. METHODS: In the present study, we performed a retrospective, observational study based on 13,403 medical records of pregnant women who delivered singleton infants at a tertiary hospital in Shanghai from 1 January 2018 through 31 December 2019. We split the original dataset into a training set (n = 9382) and a validation set (n = 4021) at a 7:3 ratio to generate and validate our model. The candidate variables, including maternal characteristics, laboratory tests, and sonographic parameters were compared between the two groups. A univariate and multivariate logistic regression was carried out to explore the independent risk factors for macrosomia in pregnant women. Thus, the regression model was adopted to establish a nomogram to predict the risk of macrosomia. Nomogram performance was determined by discrimination and calibration metrics. All the statistical analysis was analyzed using R software. RESULTS: We compared the differences between the macrosomic and non-macrosomic groups within the training set and found 16 independent risk factors for macrosomia (P < 0.05), including biparietal diameter (BPD), head circumference (HC), femur length (FL), amniotic fluid index (AFI) at the last prenatal examination, pre-pregnancy body mass index (BMI), and triglycerides (TG). Values for the areas under the curve (AUC) for the nomogram model were 0.917 (95% CI, 0.908–0.927) and 0.910 (95% CI, 0.894–0.927) in the training set and validation set, respectively. The internal and external validation of the nomogram demonstrated favorable calibration as well as discriminatory capability of the model. CONCLUSIONS: Our model has precise discrimination and calibration capabilities, which can help clinical healthcare staff accurately predict macrosomia in pregnant women. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s12884-022-04981-9. |
---|