Cargando…
The Optos 200Tx Scanning Laser Ophthalmoscope Application in Retinoblastoma Patients' Follow-Up
METHODS: A total of 1134 examinations with Optomap 200Tx were performed for 318 children who were clinically diagnosed with RB in the Ophthalmology Department of Tianjin Medical University Eye Hospital, China, between July 2015 and July 2017, and achieved stable disease lasting for more than 6 month...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9388307/ https://www.ncbi.nlm.nih.gov/pubmed/35993040 http://dx.doi.org/10.1155/2022/5422360 |
_version_ | 1784770198237085696 |
---|---|
author | Cui, Xuehao Ji, Xunda Shao, Yan Zhao, Peiquan Li, Xiaorong |
author_facet | Cui, Xuehao Ji, Xunda Shao, Yan Zhao, Peiquan Li, Xiaorong |
author_sort | Cui, Xuehao |
collection | PubMed |
description | METHODS: A total of 1134 examinations with Optomap 200Tx were performed for 318 children who were clinically diagnosed with RB in the Ophthalmology Department of Tianjin Medical University Eye Hospital, China, between July 2015 and July 2017, and achieved stable disease lasting for more than 6 months after combined treatment. The children received examinations every 1-12 months (mean 4 months), initially at 31 months to 15 years of age (mean 51 months), and were given a full eye examination under anesthesia (EUA) immediately if recurrent tumor, recurrent vitreous seeding (VS), or recurrent subretinal seeding (SRS) was detected, or in the next follow-up visit if no abnormality was detected, and early treatment was performed when the lesion was confirmed. RESULTS: Recurrence was detected in 4 children in the examination with Optomap 200Tx, including 2 cases of recurrent vitreous seeding (VS) and 2 cases of recurrent subretinal seeding (SRS), which were confirmed by EUA and well controlled after early treatment. CONCLUSION: The use of Optomap 200Tx in the long-term following up of patients with RB reduces the number of eye examinations under general anesthesia (EUA), increases the time between EUAs, and protects children from exposure to the adverse effects of general anesthetics. Optomap 200Tx can detect recurrent tumor and recurrent seeding, allowing for early treatment which produces better outcomes. |
format | Online Article Text |
id | pubmed-9388307 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Hindawi |
record_format | MEDLINE/PubMed |
spelling | pubmed-93883072022-08-19 The Optos 200Tx Scanning Laser Ophthalmoscope Application in Retinoblastoma Patients' Follow-Up Cui, Xuehao Ji, Xunda Shao, Yan Zhao, Peiquan Li, Xiaorong Biomed Res Int Research Article METHODS: A total of 1134 examinations with Optomap 200Tx were performed for 318 children who were clinically diagnosed with RB in the Ophthalmology Department of Tianjin Medical University Eye Hospital, China, between July 2015 and July 2017, and achieved stable disease lasting for more than 6 months after combined treatment. The children received examinations every 1-12 months (mean 4 months), initially at 31 months to 15 years of age (mean 51 months), and were given a full eye examination under anesthesia (EUA) immediately if recurrent tumor, recurrent vitreous seeding (VS), or recurrent subretinal seeding (SRS) was detected, or in the next follow-up visit if no abnormality was detected, and early treatment was performed when the lesion was confirmed. RESULTS: Recurrence was detected in 4 children in the examination with Optomap 200Tx, including 2 cases of recurrent vitreous seeding (VS) and 2 cases of recurrent subretinal seeding (SRS), which were confirmed by EUA and well controlled after early treatment. CONCLUSION: The use of Optomap 200Tx in the long-term following up of patients with RB reduces the number of eye examinations under general anesthesia (EUA), increases the time between EUAs, and protects children from exposure to the adverse effects of general anesthetics. Optomap 200Tx can detect recurrent tumor and recurrent seeding, allowing for early treatment which produces better outcomes. Hindawi 2022-08-11 /pmc/articles/PMC9388307/ /pubmed/35993040 http://dx.doi.org/10.1155/2022/5422360 Text en Copyright © 2022 Xuehao Cui et al. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Cui, Xuehao Ji, Xunda Shao, Yan Zhao, Peiquan Li, Xiaorong The Optos 200Tx Scanning Laser Ophthalmoscope Application in Retinoblastoma Patients' Follow-Up |
title | The Optos 200Tx Scanning Laser Ophthalmoscope Application in Retinoblastoma Patients' Follow-Up |
title_full | The Optos 200Tx Scanning Laser Ophthalmoscope Application in Retinoblastoma Patients' Follow-Up |
title_fullStr | The Optos 200Tx Scanning Laser Ophthalmoscope Application in Retinoblastoma Patients' Follow-Up |
title_full_unstemmed | The Optos 200Tx Scanning Laser Ophthalmoscope Application in Retinoblastoma Patients' Follow-Up |
title_short | The Optos 200Tx Scanning Laser Ophthalmoscope Application in Retinoblastoma Patients' Follow-Up |
title_sort | optos 200tx scanning laser ophthalmoscope application in retinoblastoma patients' follow-up |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9388307/ https://www.ncbi.nlm.nih.gov/pubmed/35993040 http://dx.doi.org/10.1155/2022/5422360 |
work_keys_str_mv | AT cuixuehao theoptos200txscanninglaserophthalmoscopeapplicationinretinoblastomapatientsfollowup AT jixunda theoptos200txscanninglaserophthalmoscopeapplicationinretinoblastomapatientsfollowup AT shaoyan theoptos200txscanninglaserophthalmoscopeapplicationinretinoblastomapatientsfollowup AT zhaopeiquan theoptos200txscanninglaserophthalmoscopeapplicationinretinoblastomapatientsfollowup AT lixiaorong theoptos200txscanninglaserophthalmoscopeapplicationinretinoblastomapatientsfollowup AT cuixuehao optos200txscanninglaserophthalmoscopeapplicationinretinoblastomapatientsfollowup AT jixunda optos200txscanninglaserophthalmoscopeapplicationinretinoblastomapatientsfollowup AT shaoyan optos200txscanninglaserophthalmoscopeapplicationinretinoblastomapatientsfollowup AT zhaopeiquan optos200txscanninglaserophthalmoscopeapplicationinretinoblastomapatientsfollowup AT lixiaorong optos200txscanninglaserophthalmoscopeapplicationinretinoblastomapatientsfollowup |