Cargando…

Tandem Mass Spectrometry as an Independent Method for Corroborating Fluorine-18 Radioactivity Measurements in Positron Emission Tomography

[Image: see text] Positron emission tomography (PET) uses many tracers labeled with fluorine-18 (t(1/2) = 109.8 min; β(+) 97%) for quantitative imaging of biochemical and physiological processes in animal and human subjects. In PET methodology, the radioactivity in a dose of an (18)F-labeled tracer...

Descripción completa

Detalles Bibliográficos
Autores principales: Shetty, H. Umesha, Morse, Cheryl L., Pike, Victor W.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: American Chemical Society 2022
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9389646/
https://www.ncbi.nlm.nih.gov/pubmed/35996540
http://dx.doi.org/10.1021/acsmeasuresciau.2c00018
_version_ 1784770504288108544
author Shetty, H. Umesha
Morse, Cheryl L.
Pike, Victor W.
author_facet Shetty, H. Umesha
Morse, Cheryl L.
Pike, Victor W.
author_sort Shetty, H. Umesha
collection PubMed
description [Image: see text] Positron emission tomography (PET) uses many tracers labeled with fluorine-18 (t(1/2) = 109.8 min; β(+) 97%) for quantitative imaging of biochemical and physiological processes in animal and human subjects. In PET methodology, the radioactivity in a dose of an (18)F-labeled tracer to be administered to a living subject is measured with a calibrated ionization chamber. This type of detector measures the radioactivity of a sample relative to those of certified amounts of longer-lived surrogate isotopes that are recommended for detector calibration. No alternative means for corroborating widely varying fluorine-18 radioactivity measurements from calibrated ionization chambers has been available. Here, we describe an independent nonradiometric method for this purpose. In this method, highly sensitive liquid chromatography–tandem mass spectrometry (LC–MS/MS) is used to quantify the relative masses of the radioactive isotopologue ([(18)F]1) and the accompanying nonradioactive counterpart (carrier 1) in an (18)F-labeled tracer preparation to give the mole ratio of [(18)F]1. High-performance liquid chromatography (HPLC) with a mass-calibrated absorbance detection is used alongside to provide a separate measurement of the aggregate mass of all isotopologues. The radioactivity of the radiotracer is then derived in becquerels (Bq) from these two measurements, plus Avogadro’s number and the decay constant of fluorine-18. For the chosen example [(18)F]LSN3316612, the radioactivity values determined nonradiometrically and with a selected ionization chamber were in fair agreement. In addition, LC–MS/MS alone was found to provide an accurate measure of the half-life of fluorine-18.
format Online
Article
Text
id pubmed-9389646
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher American Chemical Society
record_format MEDLINE/PubMed
spelling pubmed-93896462022-08-20 Tandem Mass Spectrometry as an Independent Method for Corroborating Fluorine-18 Radioactivity Measurements in Positron Emission Tomography Shetty, H. Umesha Morse, Cheryl L. Pike, Victor W. ACS Meas Sci Au [Image: see text] Positron emission tomography (PET) uses many tracers labeled with fluorine-18 (t(1/2) = 109.8 min; β(+) 97%) for quantitative imaging of biochemical and physiological processes in animal and human subjects. In PET methodology, the radioactivity in a dose of an (18)F-labeled tracer to be administered to a living subject is measured with a calibrated ionization chamber. This type of detector measures the radioactivity of a sample relative to those of certified amounts of longer-lived surrogate isotopes that are recommended for detector calibration. No alternative means for corroborating widely varying fluorine-18 radioactivity measurements from calibrated ionization chambers has been available. Here, we describe an independent nonradiometric method for this purpose. In this method, highly sensitive liquid chromatography–tandem mass spectrometry (LC–MS/MS) is used to quantify the relative masses of the radioactive isotopologue ([(18)F]1) and the accompanying nonradioactive counterpart (carrier 1) in an (18)F-labeled tracer preparation to give the mole ratio of [(18)F]1. High-performance liquid chromatography (HPLC) with a mass-calibrated absorbance detection is used alongside to provide a separate measurement of the aggregate mass of all isotopologues. The radioactivity of the radiotracer is then derived in becquerels (Bq) from these two measurements, plus Avogadro’s number and the decay constant of fluorine-18. For the chosen example [(18)F]LSN3316612, the radioactivity values determined nonradiometrically and with a selected ionization chamber were in fair agreement. In addition, LC–MS/MS alone was found to provide an accurate measure of the half-life of fluorine-18. American Chemical Society 2022-06-23 /pmc/articles/PMC9389646/ /pubmed/35996540 http://dx.doi.org/10.1021/acsmeasuresciau.2c00018 Text en Not subject to U.S. Copyright. Published 2022 by American Chemical Society https://creativecommons.org/licenses/by-nc-nd/4.0/Permits non-commercial access and re-use, provided that author attribution and integrity are maintained; but does not permit creation of adaptations or other derivative works (https://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Shetty, H. Umesha
Morse, Cheryl L.
Pike, Victor W.
Tandem Mass Spectrometry as an Independent Method for Corroborating Fluorine-18 Radioactivity Measurements in Positron Emission Tomography
title Tandem Mass Spectrometry as an Independent Method for Corroborating Fluorine-18 Radioactivity Measurements in Positron Emission Tomography
title_full Tandem Mass Spectrometry as an Independent Method for Corroborating Fluorine-18 Radioactivity Measurements in Positron Emission Tomography
title_fullStr Tandem Mass Spectrometry as an Independent Method for Corroborating Fluorine-18 Radioactivity Measurements in Positron Emission Tomography
title_full_unstemmed Tandem Mass Spectrometry as an Independent Method for Corroborating Fluorine-18 Radioactivity Measurements in Positron Emission Tomography
title_short Tandem Mass Spectrometry as an Independent Method for Corroborating Fluorine-18 Radioactivity Measurements in Positron Emission Tomography
title_sort tandem mass spectrometry as an independent method for corroborating fluorine-18 radioactivity measurements in positron emission tomography
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9389646/
https://www.ncbi.nlm.nih.gov/pubmed/35996540
http://dx.doi.org/10.1021/acsmeasuresciau.2c00018
work_keys_str_mv AT shettyhumesha tandemmassspectrometryasanindependentmethodforcorroboratingfluorine18radioactivitymeasurementsinpositronemissiontomography
AT morsecheryll tandemmassspectrometryasanindependentmethodforcorroboratingfluorine18radioactivitymeasurementsinpositronemissiontomography
AT pikevictorw tandemmassspectrometryasanindependentmethodforcorroboratingfluorine18radioactivitymeasurementsinpositronemissiontomography