Application of green first derivative synchronous spectrofluorometric method for quantitative analysis of fexofenadine hydrochloride and pseudoephedrine hydrochloride in pharmaceutical preparation and spiked human plasma

Fexofenadine hydrochloride and pseudoephedrine hydrochloride are prescribed in a combined dosage form for the treatment of allergic rhinitis. In the present work, a sensitive synchronous fluorescence spectroscopic method was applied in conjunction with first derivative for quantitative estimation of...

Descripción completa

Detalles Bibliográficos
Autores principales: Ramzy, Sherif, Abdelazim, Ahmed H., Hasan, Mohamed A.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer International Publishing 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9389777/
https://www.ncbi.nlm.nih.gov/pubmed/35986381
http://dx.doi.org/10.1186/s13065-022-00855-5
_version_ 1784770530204712960
author Ramzy, Sherif
Abdelazim, Ahmed H.
Hasan, Mohamed A.
author_facet Ramzy, Sherif
Abdelazim, Ahmed H.
Hasan, Mohamed A.
author_sort Ramzy, Sherif
collection PubMed
description Fexofenadine hydrochloride and pseudoephedrine hydrochloride are prescribed in a combined dosage form for the treatment of allergic rhinitis. In the present work, a sensitive synchronous fluorescence spectroscopic method was applied in conjunction with first derivative for quantitative estimation of fexofenadine hydrochloride and pseudoephedrine hydrochloride in pure form, pharmaceutical tablets and spiked human plasma. Fexofenadine hydrochloride showed its conventional emission spectrum at 294 nm when excited at 267 nm. On the other hand, pseudoephedrine hydrochloride showed its conventional emission spectra at 286 nm when excited at 261 nm. The fluorescence intensities were greatly enhanced by the use of sodium dodecyl sulphate as a micellar surfactant. Application of the synchronous mode to measure the fluorescence spectra of the above drugs provided sharp narrowing bands, but the overlap was not completely resolved. Derivatization of the synchronous spectra to the first order completely resolved the overlap of the fluorescence spectra and allowed simultaneous quantitative determination of the drugs under study. Fexofenadine hydrochloride and pseudoephedrine hydrochloride could be determined from their first-order synchronous spectra at 286 and 294 nm, respectively, without interfering with each other. The method showed linearity with an excellent correlation coefficient in the concentration range of 100–1500 ng/mL for Fexofenadine hydrochloride and 50–1000 ng/mL for pseudoephedrine hydrochloride. The method was successfully applied for the simultaneous determination of the studied drugs in pharmaceutical formulation, with mean percent recoveries for Fexofenadine hydrochloride and pseudoephedrine hydrochloride of 99.49 ± 0.931 and 98.67 ± 0.634, respectively, and in spiked human plasma, with mean percent recoveries for Fexofenadine hydrochloride and pseudoephedrine hydrochloride of 95.21 ± 1.938 and 94.89 ± 1.763, respectively. Furthermore, the greenness of the described method was assessed using four different tools namely, the national environmental method index, the analytical eco-scale, the green analytical procedure index and the AGREE evaluation method. The proposed method seemed to be superior to the reported HPLC method with respect to the metrics of the greenness characters.
format Online
Article
Text
id pubmed-9389777
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Springer International Publishing
record_format MEDLINE/PubMed
spelling pubmed-93897772022-08-20 Application of green first derivative synchronous spectrofluorometric method for quantitative analysis of fexofenadine hydrochloride and pseudoephedrine hydrochloride in pharmaceutical preparation and spiked human plasma Ramzy, Sherif Abdelazim, Ahmed H. Hasan, Mohamed A. BMC Chem Research Fexofenadine hydrochloride and pseudoephedrine hydrochloride are prescribed in a combined dosage form for the treatment of allergic rhinitis. In the present work, a sensitive synchronous fluorescence spectroscopic method was applied in conjunction with first derivative for quantitative estimation of fexofenadine hydrochloride and pseudoephedrine hydrochloride in pure form, pharmaceutical tablets and spiked human plasma. Fexofenadine hydrochloride showed its conventional emission spectrum at 294 nm when excited at 267 nm. On the other hand, pseudoephedrine hydrochloride showed its conventional emission spectra at 286 nm when excited at 261 nm. The fluorescence intensities were greatly enhanced by the use of sodium dodecyl sulphate as a micellar surfactant. Application of the synchronous mode to measure the fluorescence spectra of the above drugs provided sharp narrowing bands, but the overlap was not completely resolved. Derivatization of the synchronous spectra to the first order completely resolved the overlap of the fluorescence spectra and allowed simultaneous quantitative determination of the drugs under study. Fexofenadine hydrochloride and pseudoephedrine hydrochloride could be determined from their first-order synchronous spectra at 286 and 294 nm, respectively, without interfering with each other. The method showed linearity with an excellent correlation coefficient in the concentration range of 100–1500 ng/mL for Fexofenadine hydrochloride and 50–1000 ng/mL for pseudoephedrine hydrochloride. The method was successfully applied for the simultaneous determination of the studied drugs in pharmaceutical formulation, with mean percent recoveries for Fexofenadine hydrochloride and pseudoephedrine hydrochloride of 99.49 ± 0.931 and 98.67 ± 0.634, respectively, and in spiked human plasma, with mean percent recoveries for Fexofenadine hydrochloride and pseudoephedrine hydrochloride of 95.21 ± 1.938 and 94.89 ± 1.763, respectively. Furthermore, the greenness of the described method was assessed using four different tools namely, the national environmental method index, the analytical eco-scale, the green analytical procedure index and the AGREE evaluation method. The proposed method seemed to be superior to the reported HPLC method with respect to the metrics of the greenness characters. Springer International Publishing 2022-08-19 /pmc/articles/PMC9389777/ /pubmed/35986381 http://dx.doi.org/10.1186/s13065-022-00855-5 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research
Ramzy, Sherif
Abdelazim, Ahmed H.
Hasan, Mohamed A.
Application of green first derivative synchronous spectrofluorometric method for quantitative analysis of fexofenadine hydrochloride and pseudoephedrine hydrochloride in pharmaceutical preparation and spiked human plasma
title Application of green first derivative synchronous spectrofluorometric method for quantitative analysis of fexofenadine hydrochloride and pseudoephedrine hydrochloride in pharmaceutical preparation and spiked human plasma
title_full Application of green first derivative synchronous spectrofluorometric method for quantitative analysis of fexofenadine hydrochloride and pseudoephedrine hydrochloride in pharmaceutical preparation and spiked human plasma
title_fullStr Application of green first derivative synchronous spectrofluorometric method for quantitative analysis of fexofenadine hydrochloride and pseudoephedrine hydrochloride in pharmaceutical preparation and spiked human plasma
title_full_unstemmed Application of green first derivative synchronous spectrofluorometric method for quantitative analysis of fexofenadine hydrochloride and pseudoephedrine hydrochloride in pharmaceutical preparation and spiked human plasma
title_short Application of green first derivative synchronous spectrofluorometric method for quantitative analysis of fexofenadine hydrochloride and pseudoephedrine hydrochloride in pharmaceutical preparation and spiked human plasma
title_sort application of green first derivative synchronous spectrofluorometric method for quantitative analysis of fexofenadine hydrochloride and pseudoephedrine hydrochloride in pharmaceutical preparation and spiked human plasma
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9389777/
https://www.ncbi.nlm.nih.gov/pubmed/35986381
http://dx.doi.org/10.1186/s13065-022-00855-5
work_keys_str_mv AT ramzysherif applicationofgreenfirstderivativesynchronousspectrofluorometricmethodforquantitativeanalysisoffexofenadinehydrochlorideandpseudoephedrinehydrochlorideinpharmaceuticalpreparationandspikedhumanplasma
AT abdelazimahmedh applicationofgreenfirstderivativesynchronousspectrofluorometricmethodforquantitativeanalysisoffexofenadinehydrochlorideandpseudoephedrinehydrochlorideinpharmaceuticalpreparationandspikedhumanplasma
AT hasanmohameda applicationofgreenfirstderivativesynchronousspectrofluorometricmethodforquantitativeanalysisoffexofenadinehydrochlorideandpseudoephedrinehydrochlorideinpharmaceuticalpreparationandspikedhumanplasma