Cargando…
Endovascular ascending aortic pseudoaneurysm repair under image fusion guidance and transcranial Doppler monitoring
We describe a 78-year-old woman with a large ascending aortic pseudoaneurysm who underwent thoracic endovascular aortic repair under intraoperative image fusion guidance and real-time transcranial Doppler (TCD) monitoring. TCD monitoring revealed a total of 419 microembolic signals throughout the pr...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9391500/ https://www.ncbi.nlm.nih.gov/pubmed/35996732 http://dx.doi.org/10.1016/j.jvscit.2022.06.009 |
_version_ | 1784770866075140096 |
---|---|
author | Fitzgerald, Lauren A. El Nihum, Lamees I. Berens, Pauline M. Chinnadurai, Ponraj Garami, Zsolt Atkins, Marvin D. |
author_facet | Fitzgerald, Lauren A. El Nihum, Lamees I. Berens, Pauline M. Chinnadurai, Ponraj Garami, Zsolt Atkins, Marvin D. |
author_sort | Fitzgerald, Lauren A. |
collection | PubMed |
description | We describe a 78-year-old woman with a large ascending aortic pseudoaneurysm who underwent thoracic endovascular aortic repair under intraoperative image fusion guidance and real-time transcranial Doppler (TCD) monitoring. TCD monitoring revealed a total of 419 microembolic signals throughout the procedure, with the majority occurring as the first stent graft crossed the ascending aorta. Two days later, she underwent endovascular repair of a graft type IA endoleak. We highlight the role of image fusion guidance and TCD monitoring in enabling successful thoracic endovascular aortic repair in an elderly woman and in identifying procedural areas of improvement to minimize stroke risk. |
format | Online Article Text |
id | pubmed-9391500 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-93915002022-08-21 Endovascular ascending aortic pseudoaneurysm repair under image fusion guidance and transcranial Doppler monitoring Fitzgerald, Lauren A. El Nihum, Lamees I. Berens, Pauline M. Chinnadurai, Ponraj Garami, Zsolt Atkins, Marvin D. J Vasc Surg Cases Innov Tech Case report We describe a 78-year-old woman with a large ascending aortic pseudoaneurysm who underwent thoracic endovascular aortic repair under intraoperative image fusion guidance and real-time transcranial Doppler (TCD) monitoring. TCD monitoring revealed a total of 419 microembolic signals throughout the procedure, with the majority occurring as the first stent graft crossed the ascending aorta. Two days later, she underwent endovascular repair of a graft type IA endoleak. We highlight the role of image fusion guidance and TCD monitoring in enabling successful thoracic endovascular aortic repair in an elderly woman and in identifying procedural areas of improvement to minimize stroke risk. Elsevier 2022-07-09 /pmc/articles/PMC9391500/ /pubmed/35996732 http://dx.doi.org/10.1016/j.jvscit.2022.06.009 Text en © 2022 The Author(s) https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Case report Fitzgerald, Lauren A. El Nihum, Lamees I. Berens, Pauline M. Chinnadurai, Ponraj Garami, Zsolt Atkins, Marvin D. Endovascular ascending aortic pseudoaneurysm repair under image fusion guidance and transcranial Doppler monitoring |
title | Endovascular ascending aortic pseudoaneurysm repair under image fusion guidance and transcranial Doppler monitoring |
title_full | Endovascular ascending aortic pseudoaneurysm repair under image fusion guidance and transcranial Doppler monitoring |
title_fullStr | Endovascular ascending aortic pseudoaneurysm repair under image fusion guidance and transcranial Doppler monitoring |
title_full_unstemmed | Endovascular ascending aortic pseudoaneurysm repair under image fusion guidance and transcranial Doppler monitoring |
title_short | Endovascular ascending aortic pseudoaneurysm repair under image fusion guidance and transcranial Doppler monitoring |
title_sort | endovascular ascending aortic pseudoaneurysm repair under image fusion guidance and transcranial doppler monitoring |
topic | Case report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9391500/ https://www.ncbi.nlm.nih.gov/pubmed/35996732 http://dx.doi.org/10.1016/j.jvscit.2022.06.009 |
work_keys_str_mv | AT fitzgeraldlaurena endovascularascendingaorticpseudoaneurysmrepairunderimagefusionguidanceandtranscranialdopplermonitoring AT elnihumlameesi endovascularascendingaorticpseudoaneurysmrepairunderimagefusionguidanceandtranscranialdopplermonitoring AT berenspaulinem endovascularascendingaorticpseudoaneurysmrepairunderimagefusionguidanceandtranscranialdopplermonitoring AT chinnaduraiponraj endovascularascendingaorticpseudoaneurysmrepairunderimagefusionguidanceandtranscranialdopplermonitoring AT garamizsolt endovascularascendingaorticpseudoaneurysmrepairunderimagefusionguidanceandtranscranialdopplermonitoring AT atkinsmarvind endovascularascendingaorticpseudoaneurysmrepairunderimagefusionguidanceandtranscranialdopplermonitoring |