Cargando…

Can the MRI based AMADEUS score accurately assess pre-surgery chondral defect severity according to the ICRS arthroscopic classification system?

PURPOSE: The AMADEUS (Area Measurement And DEpth and Underlying Structures) scoring and grading system has been proposed for the MRI based evaluation of untreated focal chondral defects around the knee. The clinical practicability, its correlation with arthroscopically assessed grading systems (ICRS...

Descripción completa

Detalles Bibliográficos
Autores principales: Heinz, Tizian, Meller, Felix, Luetkens, Karsten Sebastian, Horas, Konstantin, Schäfer, Thomas, Rudert, Maximilian, Reppenhagen, Stephan, Weißenberger, Manuel
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9391552/
https://www.ncbi.nlm.nih.gov/pubmed/35986190
http://dx.doi.org/10.1186/s40634-022-00511-w
_version_ 1784770875481915392
author Heinz, Tizian
Meller, Felix
Luetkens, Karsten Sebastian
Horas, Konstantin
Schäfer, Thomas
Rudert, Maximilian
Reppenhagen, Stephan
Weißenberger, Manuel
author_facet Heinz, Tizian
Meller, Felix
Luetkens, Karsten Sebastian
Horas, Konstantin
Schäfer, Thomas
Rudert, Maximilian
Reppenhagen, Stephan
Weißenberger, Manuel
author_sort Heinz, Tizian
collection PubMed
description PURPOSE: The AMADEUS (Area Measurement And DEpth and Underlying Structures) scoring and grading system has been proposed for the MRI based evaluation of untreated focal chondral defects around the knee. The clinical practicability, its correlation with arthroscopically assessed grading systems (ICRS – International Cartilage Repair Society) and thereby its clinical value in terms of decision making and guiding prognosis was yet to determine. METHODS: From 2008 to 2019 a total of 89 individuals were indicated for high tibial valgus osteotomy (HTO) due to tibial varus deformity and concomitant chondral defects of the medial compartment of the knee. All patients received a preoperative MRI (1.5 Tesla or 3.0 Tesla) and pre-osteotomy diagnostic arthroscopy. Chondral defects of the medial compartment were scored and graded with the MRI based AMADEUS by three independent raters and compared to arthroscopic defect grading by the ICRS system. Interrater and intrarater reliability as well as correlation analysis with the ICRS classification system were assessed. RESULTS: Intraclass correlation coefficients for the various subscores of the AMADEUS showed an overall good to excellent interrater agreement (min: 0.26, max: 0.80). Intrarater agreement turned out to be substantially inferior (min: 0.08, max: 0.53). Spearman correlation revealed an overall moderate correlative association of the AMADEUS subscores with the ICRS classification system, apart from the defect area subscore. Sensitivity of the AMADEUS to accurately identify defect severity according to the ICRS was 0.7 (0.69 for 3.0 Tesla MRI, 0.67 for 1.5 Tesla MRI). The mean AMADEUS grade was 2.60 ± 0.81 and the mean ICRS score 2.90 ± 0.63. CONCLUSIONS: Overall, the AMADEUS with all its subscores shows moderate correlation with the arthroscopic chondral grading system according to ICRS. This suggests that chondral defect grading by means of the MRI based AMADEUS is well capable of influencing and guiding treatment decisions. Interrater reliability shows overall good agreement.
format Online
Article
Text
id pubmed-9391552
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Springer Berlin Heidelberg
record_format MEDLINE/PubMed
spelling pubmed-93915522022-08-21 Can the MRI based AMADEUS score accurately assess pre-surgery chondral defect severity according to the ICRS arthroscopic classification system? Heinz, Tizian Meller, Felix Luetkens, Karsten Sebastian Horas, Konstantin Schäfer, Thomas Rudert, Maximilian Reppenhagen, Stephan Weißenberger, Manuel J Exp Orthop Original Paper PURPOSE: The AMADEUS (Area Measurement And DEpth and Underlying Structures) scoring and grading system has been proposed for the MRI based evaluation of untreated focal chondral defects around the knee. The clinical practicability, its correlation with arthroscopically assessed grading systems (ICRS – International Cartilage Repair Society) and thereby its clinical value in terms of decision making and guiding prognosis was yet to determine. METHODS: From 2008 to 2019 a total of 89 individuals were indicated for high tibial valgus osteotomy (HTO) due to tibial varus deformity and concomitant chondral defects of the medial compartment of the knee. All patients received a preoperative MRI (1.5 Tesla or 3.0 Tesla) and pre-osteotomy diagnostic arthroscopy. Chondral defects of the medial compartment were scored and graded with the MRI based AMADEUS by three independent raters and compared to arthroscopic defect grading by the ICRS system. Interrater and intrarater reliability as well as correlation analysis with the ICRS classification system were assessed. RESULTS: Intraclass correlation coefficients for the various subscores of the AMADEUS showed an overall good to excellent interrater agreement (min: 0.26, max: 0.80). Intrarater agreement turned out to be substantially inferior (min: 0.08, max: 0.53). Spearman correlation revealed an overall moderate correlative association of the AMADEUS subscores with the ICRS classification system, apart from the defect area subscore. Sensitivity of the AMADEUS to accurately identify defect severity according to the ICRS was 0.7 (0.69 for 3.0 Tesla MRI, 0.67 for 1.5 Tesla MRI). The mean AMADEUS grade was 2.60 ± 0.81 and the mean ICRS score 2.90 ± 0.63. CONCLUSIONS: Overall, the AMADEUS with all its subscores shows moderate correlation with the arthroscopic chondral grading system according to ICRS. This suggests that chondral defect grading by means of the MRI based AMADEUS is well capable of influencing and guiding treatment decisions. Interrater reliability shows overall good agreement. Springer Berlin Heidelberg 2022-08-19 /pmc/articles/PMC9391552/ /pubmed/35986190 http://dx.doi.org/10.1186/s40634-022-00511-w Text en © The Author(s) 2022, corrected publication 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Original Paper
Heinz, Tizian
Meller, Felix
Luetkens, Karsten Sebastian
Horas, Konstantin
Schäfer, Thomas
Rudert, Maximilian
Reppenhagen, Stephan
Weißenberger, Manuel
Can the MRI based AMADEUS score accurately assess pre-surgery chondral defect severity according to the ICRS arthroscopic classification system?
title Can the MRI based AMADEUS score accurately assess pre-surgery chondral defect severity according to the ICRS arthroscopic classification system?
title_full Can the MRI based AMADEUS score accurately assess pre-surgery chondral defect severity according to the ICRS arthroscopic classification system?
title_fullStr Can the MRI based AMADEUS score accurately assess pre-surgery chondral defect severity according to the ICRS arthroscopic classification system?
title_full_unstemmed Can the MRI based AMADEUS score accurately assess pre-surgery chondral defect severity according to the ICRS arthroscopic classification system?
title_short Can the MRI based AMADEUS score accurately assess pre-surgery chondral defect severity according to the ICRS arthroscopic classification system?
title_sort can the mri based amadeus score accurately assess pre-surgery chondral defect severity according to the icrs arthroscopic classification system?
topic Original Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9391552/
https://www.ncbi.nlm.nih.gov/pubmed/35986190
http://dx.doi.org/10.1186/s40634-022-00511-w
work_keys_str_mv AT heinztizian canthemribasedamadeusscoreaccuratelyassesspresurgerychondraldefectseverityaccordingtotheicrsarthroscopicclassificationsystem
AT mellerfelix canthemribasedamadeusscoreaccuratelyassesspresurgerychondraldefectseverityaccordingtotheicrsarthroscopicclassificationsystem
AT luetkenskarstensebastian canthemribasedamadeusscoreaccuratelyassesspresurgerychondraldefectseverityaccordingtotheicrsarthroscopicclassificationsystem
AT horaskonstantin canthemribasedamadeusscoreaccuratelyassesspresurgerychondraldefectseverityaccordingtotheicrsarthroscopicclassificationsystem
AT schaferthomas canthemribasedamadeusscoreaccuratelyassesspresurgerychondraldefectseverityaccordingtotheicrsarthroscopicclassificationsystem
AT rudertmaximilian canthemribasedamadeusscoreaccuratelyassesspresurgerychondraldefectseverityaccordingtotheicrsarthroscopicclassificationsystem
AT reppenhagenstephan canthemribasedamadeusscoreaccuratelyassesspresurgerychondraldefectseverityaccordingtotheicrsarthroscopicclassificationsystem
AT weißenbergermanuel canthemribasedamadeusscoreaccuratelyassesspresurgerychondraldefectseverityaccordingtotheicrsarthroscopicclassificationsystem