BACKGROUND AND OBJECTIVES: Cardiac Magnetic Resonance Imaging (MRI) is a technique used for evaluation of children with congenital heart diseases. General anesthesia ensures immobility, particularly in uncooperative patients. However, chest wall movements can limit good quality scans. Prolonged apne...

Descripción completa

Detalles Bibliográficos
Autores principales: Rodrigues, João Tiago, Oliveira, Carmen, Ferreira, Ana Pinto
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9391913/
https://www.ncbi.nlm.nih.gov/pubmed/31796302
http://dx.doi.org/10.1016/j.bjane.2019.08.005
Descripción
Sumario:BACKGROUND AND OBJECTIVES: Cardiac Magnetic Resonance Imaging (MRI) is a technique used for evaluation of children with congenital heart diseases. General anesthesia ensures immobility, particularly in uncooperative patients. However, chest wall movements can limit good quality scans. Prolonged apnea may be necessary to decrease respiratory motion artefacts, potentially leading to hypoxemia and other adverse events. The use of a high frequency jet ventilator may be a solution avoiding chest wall movements. CASE REPORT: We report four cases of pediatric patients, ASA II, aged between 4 and 15 years-old, scheduled for cardiac MRI. General anesthesia was proposed and parental informed consent was obtained. After general anesthesia was induced, an uncuffed endotracheal tube was inserted. Then, a 7Fr × 40 cm catheter was placed through the endotracheal tube. The proximal outlet of the catheter was attached through a connecting tube to a high frequency jet ventilator (Monsoon III®, Acutronic Medical Systems). Good quality MRI images were obtained. At the end of the procedures, we observed increased salivation and increased end-tidal CO(2) (60–70 mmHg), in all patients. The patients were extubated after normocapnia was achieved and neuromuscular blockade reversed. Following appropriate recovery time, the four children were discharged home the same day. CONCLUSIONS: This case series demonstrates that the use of a high frequency jet ventilator for cardiac MRI was feasible, safe, providing good quality cardiac imaging and avoiding anesthesia personnel to be inside the hazardous environment of MRI room. Future studies are needed to confirm its safety and efficiency in pediatric patients.