Cargando…

Preliminary study to determine an optimal mode for favorable residual hearing at low frequencies: Full electrical stimulation, electric acoustic stimulation, and electrical complement

OBJECTIVE: In this prospective study, each subject experienced three modes electric acoustic stimulation (EAS), full electrical stimulation (FES), and electrical complement (EC), and the performance of each mode and subject preference were evaluated. METHODS: Eight ears (seven patients) with success...

Descripción completa

Detalles Bibliográficos
Autores principales: Jang, Jeong Hun, Kim, Hantai, Choo, Oak‐Sung, Ha, Jungho, Mun, Hyoung Ah, Park, Hun Yi, Choung, Yun‐Hoon
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley & Sons, Inc. 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9392387/
https://www.ncbi.nlm.nih.gov/pubmed/36000067
http://dx.doi.org/10.1002/lio2.843
_version_ 1784771050540630016
author Jang, Jeong Hun
Kim, Hantai
Choo, Oak‐Sung
Ha, Jungho
Mun, Hyoung Ah
Park, Hun Yi
Choung, Yun‐Hoon
author_facet Jang, Jeong Hun
Kim, Hantai
Choo, Oak‐Sung
Ha, Jungho
Mun, Hyoung Ah
Park, Hun Yi
Choung, Yun‐Hoon
author_sort Jang, Jeong Hun
collection PubMed
description OBJECTIVE: In this prospective study, each subject experienced three modes electric acoustic stimulation (EAS), full electrical stimulation (FES), and electrical complement (EC), and the performance of each mode and subject preference were evaluated. METHODS: Eight ears (seven patients) with successfully preserved residual hearing after cochlear implantation (CI) were included. EAS, FES, and EC programs were set up on each patient's device, and each mode was used for at least 1 h per day for a month. The Speech Intelligibility test, the Speech, Spatial and Qualities of Hearing Scale, and the Hearing in Noise test (HINT) results in each stimulation mode. RESULTS: The mean monosyllabic word score (EAS: 90.3 ± 4.0; FES: 81.2 ± 16.1) and the mean sentence score (EAS: 98.3 ± 1.7; FES: 95.0 ± 3.0) were significantly higher in the EAS mode than in the FES mode. The mean bisyllabic word score (EAS: 95.6 ± 5.6; EC: 90.1 ± 5.6) was higher in the EAS mode than in the EC mode. In HINT, the signal‐to‐noise ratios under the noise front (EAS: 4.7 ± 2.5; FES: 7.9 ± 4.4) and noise composite conditions (EAS: 4.2 ± 2.7; FES: 6.6 ± 4.0) were significantly smaller in the EAS mode than in the FES mode. After trials of the three modes, five subjects preferred EAS, one preferred EC, and two preferred FES. CONCLUSION: Among the three stimulation modes, EAS produced slightly better results, and subjects generally preferred EAS (five of seven patients, 71.4%). The use of hearing aids before CI was considered an important factor in mode preference. FES may be preferred when CI was performed at a young age and subjects had little experience with hearing aids. However, adults may prefer EC over EAS if there was little or no hearing‐aid use before CI.
format Online
Article
Text
id pubmed-9392387
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher John Wiley & Sons, Inc.
record_format MEDLINE/PubMed
spelling pubmed-93923872022-08-22 Preliminary study to determine an optimal mode for favorable residual hearing at low frequencies: Full electrical stimulation, electric acoustic stimulation, and electrical complement Jang, Jeong Hun Kim, Hantai Choo, Oak‐Sung Ha, Jungho Mun, Hyoung Ah Park, Hun Yi Choung, Yun‐Hoon Laryngoscope Investig Otolaryngol Otology, Neurotology, and Neuroscience OBJECTIVE: In this prospective study, each subject experienced three modes electric acoustic stimulation (EAS), full electrical stimulation (FES), and electrical complement (EC), and the performance of each mode and subject preference were evaluated. METHODS: Eight ears (seven patients) with successfully preserved residual hearing after cochlear implantation (CI) were included. EAS, FES, and EC programs were set up on each patient's device, and each mode was used for at least 1 h per day for a month. The Speech Intelligibility test, the Speech, Spatial and Qualities of Hearing Scale, and the Hearing in Noise test (HINT) results in each stimulation mode. RESULTS: The mean monosyllabic word score (EAS: 90.3 ± 4.0; FES: 81.2 ± 16.1) and the mean sentence score (EAS: 98.3 ± 1.7; FES: 95.0 ± 3.0) were significantly higher in the EAS mode than in the FES mode. The mean bisyllabic word score (EAS: 95.6 ± 5.6; EC: 90.1 ± 5.6) was higher in the EAS mode than in the EC mode. In HINT, the signal‐to‐noise ratios under the noise front (EAS: 4.7 ± 2.5; FES: 7.9 ± 4.4) and noise composite conditions (EAS: 4.2 ± 2.7; FES: 6.6 ± 4.0) were significantly smaller in the EAS mode than in the FES mode. After trials of the three modes, five subjects preferred EAS, one preferred EC, and two preferred FES. CONCLUSION: Among the three stimulation modes, EAS produced slightly better results, and subjects generally preferred EAS (five of seven patients, 71.4%). The use of hearing aids before CI was considered an important factor in mode preference. FES may be preferred when CI was performed at a young age and subjects had little experience with hearing aids. However, adults may prefer EC over EAS if there was little or no hearing‐aid use before CI. John Wiley & Sons, Inc. 2022-06-30 /pmc/articles/PMC9392387/ /pubmed/36000067 http://dx.doi.org/10.1002/lio2.843 Text en © 2022 The Authors. Laryngoscope Investigative Otolaryngology published by Wiley Periodicals LLC on behalf of The Triological Society. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by-nc-nd/4.0/ (https://creativecommons.org/licenses/by-nc-nd/4.0/) License, which permits use and distribution in any medium, provided the original work is properly cited, the use is non‐commercial and no modifications or adaptations are made.
spellingShingle Otology, Neurotology, and Neuroscience
Jang, Jeong Hun
Kim, Hantai
Choo, Oak‐Sung
Ha, Jungho
Mun, Hyoung Ah
Park, Hun Yi
Choung, Yun‐Hoon
Preliminary study to determine an optimal mode for favorable residual hearing at low frequencies: Full electrical stimulation, electric acoustic stimulation, and electrical complement
title Preliminary study to determine an optimal mode for favorable residual hearing at low frequencies: Full electrical stimulation, electric acoustic stimulation, and electrical complement
title_full Preliminary study to determine an optimal mode for favorable residual hearing at low frequencies: Full electrical stimulation, electric acoustic stimulation, and electrical complement
title_fullStr Preliminary study to determine an optimal mode for favorable residual hearing at low frequencies: Full electrical stimulation, electric acoustic stimulation, and electrical complement
title_full_unstemmed Preliminary study to determine an optimal mode for favorable residual hearing at low frequencies: Full electrical stimulation, electric acoustic stimulation, and electrical complement
title_short Preliminary study to determine an optimal mode for favorable residual hearing at low frequencies: Full electrical stimulation, electric acoustic stimulation, and electrical complement
title_sort preliminary study to determine an optimal mode for favorable residual hearing at low frequencies: full electrical stimulation, electric acoustic stimulation, and electrical complement
topic Otology, Neurotology, and Neuroscience
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9392387/
https://www.ncbi.nlm.nih.gov/pubmed/36000067
http://dx.doi.org/10.1002/lio2.843
work_keys_str_mv AT jangjeonghun preliminarystudytodetermineanoptimalmodeforfavorableresidualhearingatlowfrequenciesfullelectricalstimulationelectricacousticstimulationandelectricalcomplement
AT kimhantai preliminarystudytodetermineanoptimalmodeforfavorableresidualhearingatlowfrequenciesfullelectricalstimulationelectricacousticstimulationandelectricalcomplement
AT choooaksung preliminarystudytodetermineanoptimalmodeforfavorableresidualhearingatlowfrequenciesfullelectricalstimulationelectricacousticstimulationandelectricalcomplement
AT hajungho preliminarystudytodetermineanoptimalmodeforfavorableresidualhearingatlowfrequenciesfullelectricalstimulationelectricacousticstimulationandelectricalcomplement
AT munhyoungah preliminarystudytodetermineanoptimalmodeforfavorableresidualhearingatlowfrequenciesfullelectricalstimulationelectricacousticstimulationandelectricalcomplement
AT parkhunyi preliminarystudytodetermineanoptimalmodeforfavorableresidualhearingatlowfrequenciesfullelectricalstimulationelectricacousticstimulationandelectricalcomplement
AT choungyunhoon preliminarystudytodetermineanoptimalmodeforfavorableresidualhearingatlowfrequenciesfullelectricalstimulationelectricacousticstimulationandelectricalcomplement