Cargando…
Diagnostic accuracy of magnetic resonance imaging for nerve injury in obstetric brachial plexus injury: protocol for systematic review and meta-analysis
BACKGROUND: Early and accurate clinical diagnosis of the extent of obstetric brachial plexus injury (OBPI) is challenging. The current gold standard for delineating the nerve injury is surgical exploration, and synchronous reconstruction is performed if indicated. Magnetic resonance imaging (MRI) is...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9392905/ https://www.ncbi.nlm.nih.gov/pubmed/35987695 http://dx.doi.org/10.1186/s13643-022-02037-9 |
_version_ | 1784771157651619840 |
---|---|
author | Hardie, Claire Brooks, James Wade, Ryckie Teh, Irvin Bourke, Grainne |
author_facet | Hardie, Claire Brooks, James Wade, Ryckie Teh, Irvin Bourke, Grainne |
author_sort | Hardie, Claire |
collection | PubMed |
description | BACKGROUND: Early and accurate clinical diagnosis of the extent of obstetric brachial plexus injury (OBPI) is challenging. The current gold standard for delineating the nerve injury is surgical exploration, and synchronous reconstruction is performed if indicated. Magnetic resonance imaging (MRI) is a non-invasive method of assessing the anatomy and severity of nerve injury in OBPI but the diagnostic accuracy is unclear. The primary objective of this review is to determine the diagnostic accuracy of MRI in comparison to surgical brachial plexus exploration for detecting root avulsion in children under 5 with OBPI. The secondary objectives are to determine its’ diagnostic accuracy for detecting nerve abnormality and detecting pseudomeningocele(s) in this group. METHODS: This review will be conducted according to the Preferred Reporting Items for Systematic Reviews and Meta-Analysis (PRISMA).We will include studies reporting the accuracy of MRI (index test) compared to surgical exploration (reference standard) in detecting any of the three target conditions (root avulsion, any nerve abnormality and pseudomeningocele) in children under five with OBPI. Case reports and studies where the number of true positives, false positives, true negatives and false negatives cannot be derived will be excluded. We plan to search PubMed, Embase and CENTRAL for relevant studies from database inception to 15 June 2022. We will also search grey literature (medRxiv, bioRxiv and Google Scholar) and perform forward and backward citation chasing. Screening and full-text assessment of eligibility will be conducted by two independent reviewers, who will then both extract the relevant data. The QUADAS-2 tool will be used to assess methodological quality and risk of bias of included studies by two reviewers independently. The following test characteristics for the target conditions will be extracted: true positives, false positives, true negatives and false negatives. Estimates of sensitivity and specificity with 95% confidence intervals will be shown in forest plots for each study. If appropriate, summary sensitivities and specificities for target conditions will be obtained via meta-analyses using a bivariate model. DISCUSSION: This study will aim to clarify the diagnostic accuracy of MRI for detecting nerve injury in OBPI and define its clinical role. SYSTEMATIC REVIEW REGISTRATION: PROSPERO CRD42021267629. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s13643-022-02037-9. |
format | Online Article Text |
id | pubmed-9392905 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-93929052022-08-22 Diagnostic accuracy of magnetic resonance imaging for nerve injury in obstetric brachial plexus injury: protocol for systematic review and meta-analysis Hardie, Claire Brooks, James Wade, Ryckie Teh, Irvin Bourke, Grainne Syst Rev Protocol BACKGROUND: Early and accurate clinical diagnosis of the extent of obstetric brachial plexus injury (OBPI) is challenging. The current gold standard for delineating the nerve injury is surgical exploration, and synchronous reconstruction is performed if indicated. Magnetic resonance imaging (MRI) is a non-invasive method of assessing the anatomy and severity of nerve injury in OBPI but the diagnostic accuracy is unclear. The primary objective of this review is to determine the diagnostic accuracy of MRI in comparison to surgical brachial plexus exploration for detecting root avulsion in children under 5 with OBPI. The secondary objectives are to determine its’ diagnostic accuracy for detecting nerve abnormality and detecting pseudomeningocele(s) in this group. METHODS: This review will be conducted according to the Preferred Reporting Items for Systematic Reviews and Meta-Analysis (PRISMA).We will include studies reporting the accuracy of MRI (index test) compared to surgical exploration (reference standard) in detecting any of the three target conditions (root avulsion, any nerve abnormality and pseudomeningocele) in children under five with OBPI. Case reports and studies where the number of true positives, false positives, true negatives and false negatives cannot be derived will be excluded. We plan to search PubMed, Embase and CENTRAL for relevant studies from database inception to 15 June 2022. We will also search grey literature (medRxiv, bioRxiv and Google Scholar) and perform forward and backward citation chasing. Screening and full-text assessment of eligibility will be conducted by two independent reviewers, who will then both extract the relevant data. The QUADAS-2 tool will be used to assess methodological quality and risk of bias of included studies by two reviewers independently. The following test characteristics for the target conditions will be extracted: true positives, false positives, true negatives and false negatives. Estimates of sensitivity and specificity with 95% confidence intervals will be shown in forest plots for each study. If appropriate, summary sensitivities and specificities for target conditions will be obtained via meta-analyses using a bivariate model. DISCUSSION: This study will aim to clarify the diagnostic accuracy of MRI for detecting nerve injury in OBPI and define its clinical role. SYSTEMATIC REVIEW REGISTRATION: PROSPERO CRD42021267629. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s13643-022-02037-9. BioMed Central 2022-08-20 /pmc/articles/PMC9392905/ /pubmed/35987695 http://dx.doi.org/10.1186/s13643-022-02037-9 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Protocol Hardie, Claire Brooks, James Wade, Ryckie Teh, Irvin Bourke, Grainne Diagnostic accuracy of magnetic resonance imaging for nerve injury in obstetric brachial plexus injury: protocol for systematic review and meta-analysis |
title | Diagnostic accuracy of magnetic resonance imaging for nerve injury in obstetric brachial plexus injury: protocol for systematic review and meta-analysis |
title_full | Diagnostic accuracy of magnetic resonance imaging for nerve injury in obstetric brachial plexus injury: protocol for systematic review and meta-analysis |
title_fullStr | Diagnostic accuracy of magnetic resonance imaging for nerve injury in obstetric brachial plexus injury: protocol for systematic review and meta-analysis |
title_full_unstemmed | Diagnostic accuracy of magnetic resonance imaging for nerve injury in obstetric brachial plexus injury: protocol for systematic review and meta-analysis |
title_short | Diagnostic accuracy of magnetic resonance imaging for nerve injury in obstetric brachial plexus injury: protocol for systematic review and meta-analysis |
title_sort | diagnostic accuracy of magnetic resonance imaging for nerve injury in obstetric brachial plexus injury: protocol for systematic review and meta-analysis |
topic | Protocol |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9392905/ https://www.ncbi.nlm.nih.gov/pubmed/35987695 http://dx.doi.org/10.1186/s13643-022-02037-9 |
work_keys_str_mv | AT hardieclaire diagnosticaccuracyofmagneticresonanceimagingfornerveinjuryinobstetricbrachialplexusinjuryprotocolforsystematicreviewandmetaanalysis AT brooksjames diagnosticaccuracyofmagneticresonanceimagingfornerveinjuryinobstetricbrachialplexusinjuryprotocolforsystematicreviewandmetaanalysis AT waderyckie diagnosticaccuracyofmagneticresonanceimagingfornerveinjuryinobstetricbrachialplexusinjuryprotocolforsystematicreviewandmetaanalysis AT tehirvin diagnosticaccuracyofmagneticresonanceimagingfornerveinjuryinobstetricbrachialplexusinjuryprotocolforsystematicreviewandmetaanalysis AT bourkegrainne diagnosticaccuracyofmagneticresonanceimagingfornerveinjuryinobstetricbrachialplexusinjuryprotocolforsystematicreviewandmetaanalysis |