Cargando…

Diagnostic Accuracy of Strain Ultrasound Elastography in Thyroid Lesions Compared to Fine-Needle Aspiration Cytology

Introduction Strain ultrasound-guided elastography (USE) could be used to differentiate malignant from benign thyroid lesions if its sensitivity and specificity are significantly high. Data on whether to rely on USE in differentiating thyroid nodules are unavailable, and fine-needle aspiration cytol...

Descripción completa

Detalles Bibliográficos
Autores principales: Saleem, Aniqua, Kalsoom, Umme, Yasin, Sundas, Durrani, Misbah, Akram, Saba, Mushtaq, Riffat
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Cureus 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9393333/
https://www.ncbi.nlm.nih.gov/pubmed/36017303
http://dx.doi.org/10.7759/cureus.27185
_version_ 1784771250251366400
author Saleem, Aniqua
Kalsoom, Umme
Yasin, Sundas
Durrani, Misbah
Akram, Saba
Mushtaq, Riffat
author_facet Saleem, Aniqua
Kalsoom, Umme
Yasin, Sundas
Durrani, Misbah
Akram, Saba
Mushtaq, Riffat
author_sort Saleem, Aniqua
collection PubMed
description Introduction Strain ultrasound-guided elastography (USE) could be used to differentiate malignant from benign thyroid lesions if its sensitivity and specificity are significantly high. Data on whether to rely on USE in differentiating thyroid nodules are unavailable, and fine-needle aspiration cytology (FNAC) remains the gold standard. However, FNAC carries a significant financial burden on hospitals and psychological stress on patients. Therefore, we conducted this study to determine the diagnostic accuracy of strain USE in thyroid lesions. Methodology We conducted a descriptive cross-sectional study at the Radiology Department, Benazir Bhutto Hospital, Rawalpindi, from December 6, 2020, to June 5, 2021. The study included adult patients aged between 20 to 70 years who were referred with thyroid nodules or lesions found clinically or on routine neck ultrasound. The study excluded patients who had previous history of surgery or previously diagnosed with malignant thyroid lesions and recurrent thyroid nodules. Strain USE was performed on thyroid nodules, and the degree of strain was color-coded on a scale from red (soft, greatest elasticity) to green (intermediate, average strain) to blue (hard, no elasticity/strain). Lesions were given an elasticity score on a five-point scale. The lesion was given a score of one if the entire lesion was uniformly shaded in green. A lesion with mosaic pattern of green and blue was scored as two. A score of three denoted a lesion with green periphery and blue center on strain elastography. A score of four indicated uniform blue in the entire lesion, with green in the lesion's periphery. The highest score of five was given if the lesion and its surroundings demonstrated blue color. Ultrasound-guided FNAC of the thyroid nodules was performed following USE. Data was analyzed using IBM Corp. Released 2011. IBM SPSS Statistics for Windows, Version 20.0. Armonk, NY: IBM Corp. Mean ± standard deviation for calculating quantitative variables. Frequencies and percentages were calculated for qualitative variables. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and diagnostic accuracy of strain USE was calculated taking FNAC as gold standard. We also conducted a receiver operating characteristic curve analysis to quantify the diagnostic accuracy of strain USE in thyroid lesions. Results The study included 207 adult patients (117 women, 56.52%; 90 men, 43.48%). The study population's mean age was 50.0 ± 11.8 years (range, 20 to 70 years). Most patients (56.52%) were aged 46 to 70 years. FNAC confirmed malignant thyroid nodules in 100 cases (true positive), and nine cases (false positive) had no malignant lesions on FNAC. In USE-negative patients, 91 were true negative, while seven were false negative. Strain USE's overall sensitivity was 93.46%, specificity was 91.0%, PPV was 91.74%, NPV was 92.86%, and diagnostic accuracy was 92.27% compared to the gold standard FNAC. Conclusions Strain USE in thyroid lesions is a noninvasive modality of choice with high diagnostic accuracy and has dramatically improved our ability to diagnose malignant thyroid nodules preoperatively. Strain USE also helps the surgeons in proper decision-making. Strain USE should be used routinely in all patients with thyroid lesions to help diagnose malignant thyroid nodules preoperatively and inform proper surgical and treatment plans.
format Online
Article
Text
id pubmed-9393333
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Cureus
record_format MEDLINE/PubMed
spelling pubmed-93933332022-08-24 Diagnostic Accuracy of Strain Ultrasound Elastography in Thyroid Lesions Compared to Fine-Needle Aspiration Cytology Saleem, Aniqua Kalsoom, Umme Yasin, Sundas Durrani, Misbah Akram, Saba Mushtaq, Riffat Cureus Family/General Practice Introduction Strain ultrasound-guided elastography (USE) could be used to differentiate malignant from benign thyroid lesions if its sensitivity and specificity are significantly high. Data on whether to rely on USE in differentiating thyroid nodules are unavailable, and fine-needle aspiration cytology (FNAC) remains the gold standard. However, FNAC carries a significant financial burden on hospitals and psychological stress on patients. Therefore, we conducted this study to determine the diagnostic accuracy of strain USE in thyroid lesions. Methodology We conducted a descriptive cross-sectional study at the Radiology Department, Benazir Bhutto Hospital, Rawalpindi, from December 6, 2020, to June 5, 2021. The study included adult patients aged between 20 to 70 years who were referred with thyroid nodules or lesions found clinically or on routine neck ultrasound. The study excluded patients who had previous history of surgery or previously diagnosed with malignant thyroid lesions and recurrent thyroid nodules. Strain USE was performed on thyroid nodules, and the degree of strain was color-coded on a scale from red (soft, greatest elasticity) to green (intermediate, average strain) to blue (hard, no elasticity/strain). Lesions were given an elasticity score on a five-point scale. The lesion was given a score of one if the entire lesion was uniformly shaded in green. A lesion with mosaic pattern of green and blue was scored as two. A score of three denoted a lesion with green periphery and blue center on strain elastography. A score of four indicated uniform blue in the entire lesion, with green in the lesion's periphery. The highest score of five was given if the lesion and its surroundings demonstrated blue color. Ultrasound-guided FNAC of the thyroid nodules was performed following USE. Data was analyzed using IBM Corp. Released 2011. IBM SPSS Statistics for Windows, Version 20.0. Armonk, NY: IBM Corp. Mean ± standard deviation for calculating quantitative variables. Frequencies and percentages were calculated for qualitative variables. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and diagnostic accuracy of strain USE was calculated taking FNAC as gold standard. We also conducted a receiver operating characteristic curve analysis to quantify the diagnostic accuracy of strain USE in thyroid lesions. Results The study included 207 adult patients (117 women, 56.52%; 90 men, 43.48%). The study population's mean age was 50.0 ± 11.8 years (range, 20 to 70 years). Most patients (56.52%) were aged 46 to 70 years. FNAC confirmed malignant thyroid nodules in 100 cases (true positive), and nine cases (false positive) had no malignant lesions on FNAC. In USE-negative patients, 91 were true negative, while seven were false negative. Strain USE's overall sensitivity was 93.46%, specificity was 91.0%, PPV was 91.74%, NPV was 92.86%, and diagnostic accuracy was 92.27% compared to the gold standard FNAC. Conclusions Strain USE in thyroid lesions is a noninvasive modality of choice with high diagnostic accuracy and has dramatically improved our ability to diagnose malignant thyroid nodules preoperatively. Strain USE also helps the surgeons in proper decision-making. Strain USE should be used routinely in all patients with thyroid lesions to help diagnose malignant thyroid nodules preoperatively and inform proper surgical and treatment plans. Cureus 2022-07-23 /pmc/articles/PMC9393333/ /pubmed/36017303 http://dx.doi.org/10.7759/cureus.27185 Text en Copyright © 2022, Saleem et al. https://creativecommons.org/licenses/by/3.0/This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Family/General Practice
Saleem, Aniqua
Kalsoom, Umme
Yasin, Sundas
Durrani, Misbah
Akram, Saba
Mushtaq, Riffat
Diagnostic Accuracy of Strain Ultrasound Elastography in Thyroid Lesions Compared to Fine-Needle Aspiration Cytology
title Diagnostic Accuracy of Strain Ultrasound Elastography in Thyroid Lesions Compared to Fine-Needle Aspiration Cytology
title_full Diagnostic Accuracy of Strain Ultrasound Elastography in Thyroid Lesions Compared to Fine-Needle Aspiration Cytology
title_fullStr Diagnostic Accuracy of Strain Ultrasound Elastography in Thyroid Lesions Compared to Fine-Needle Aspiration Cytology
title_full_unstemmed Diagnostic Accuracy of Strain Ultrasound Elastography in Thyroid Lesions Compared to Fine-Needle Aspiration Cytology
title_short Diagnostic Accuracy of Strain Ultrasound Elastography in Thyroid Lesions Compared to Fine-Needle Aspiration Cytology
title_sort diagnostic accuracy of strain ultrasound elastography in thyroid lesions compared to fine-needle aspiration cytology
topic Family/General Practice
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9393333/
https://www.ncbi.nlm.nih.gov/pubmed/36017303
http://dx.doi.org/10.7759/cureus.27185
work_keys_str_mv AT saleemaniqua diagnosticaccuracyofstrainultrasoundelastographyinthyroidlesionscomparedtofineneedleaspirationcytology
AT kalsoomumme diagnosticaccuracyofstrainultrasoundelastographyinthyroidlesionscomparedtofineneedleaspirationcytology
AT yasinsundas diagnosticaccuracyofstrainultrasoundelastographyinthyroidlesionscomparedtofineneedleaspirationcytology
AT durranimisbah diagnosticaccuracyofstrainultrasoundelastographyinthyroidlesionscomparedtofineneedleaspirationcytology
AT akramsaba diagnosticaccuracyofstrainultrasoundelastographyinthyroidlesionscomparedtofineneedleaspirationcytology
AT mushtaqriffat diagnosticaccuracyofstrainultrasoundelastographyinthyroidlesionscomparedtofineneedleaspirationcytology