Cargando…

Rationale and clinical applications of 4D flow cardiovascular magnetic resonance in assessment of valvular heart disease: a comprehensive review

BACKGROUND: Accurate evaluation of valvular pathology is crucial in the timing of surgical intervention. Whilst transthoracic echocardiography is widely available and routinely used in the assessment of valvular heart disease, it is bound by several limitations. Although cardiovascular magnetic reso...

Descripción completa

Detalles Bibliográficos
Autores principales: Gorecka, Miroslawa, Bissell, Malenka M., Higgins, David M., Garg, Pankaj, Plein, Sven, Greenwood, John P.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9394062/
https://www.ncbi.nlm.nih.gov/pubmed/35989320
http://dx.doi.org/10.1186/s12968-022-00882-0
_version_ 1784771406964195328
author Gorecka, Miroslawa
Bissell, Malenka M.
Higgins, David M.
Garg, Pankaj
Plein, Sven
Greenwood, John P.
author_facet Gorecka, Miroslawa
Bissell, Malenka M.
Higgins, David M.
Garg, Pankaj
Plein, Sven
Greenwood, John P.
author_sort Gorecka, Miroslawa
collection PubMed
description BACKGROUND: Accurate evaluation of valvular pathology is crucial in the timing of surgical intervention. Whilst transthoracic echocardiography is widely available and routinely used in the assessment of valvular heart disease, it is bound by several limitations. Although cardiovascular magnetic resonance (CMR) imaging can overcome many of the challenges encountered by echocardiography, it also has a number of limitations. MAIN TEXT: 4D Flow CMR is a novel technique, which allows time-resolved, 3-dimensional imaging. It enables visualisation and direct quantification of flow and peak velocities of all valves simultaneously in one simple acquisition, without any geometric assumptions. It also has the unique ability to measure advanced haemodynamic parameters such as turbulent kinetic energy, viscous energy loss rate and wall shear stress, which may add further diagnostic and prognostic information. Although 4D Flow CMR acquisition can take 5–10 min, emerging acceleration techniques can significantly reduce scan times, making 4D Flow CMR applicable in contemporary clinical practice. CONCLUSION: 4D Flow CMR is an emerging CMR technique, which has the potential to become the new reference-standard method for the evaluation of valvular lesions. In this review, we describe the clinical applications, advantages and disadvantages of 4D Flow CMR in the assessment of valvular heart disease.
format Online
Article
Text
id pubmed-9394062
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-93940622022-08-23 Rationale and clinical applications of 4D flow cardiovascular magnetic resonance in assessment of valvular heart disease: a comprehensive review Gorecka, Miroslawa Bissell, Malenka M. Higgins, David M. Garg, Pankaj Plein, Sven Greenwood, John P. J Cardiovasc Magn Reson Review BACKGROUND: Accurate evaluation of valvular pathology is crucial in the timing of surgical intervention. Whilst transthoracic echocardiography is widely available and routinely used in the assessment of valvular heart disease, it is bound by several limitations. Although cardiovascular magnetic resonance (CMR) imaging can overcome many of the challenges encountered by echocardiography, it also has a number of limitations. MAIN TEXT: 4D Flow CMR is a novel technique, which allows time-resolved, 3-dimensional imaging. It enables visualisation and direct quantification of flow and peak velocities of all valves simultaneously in one simple acquisition, without any geometric assumptions. It also has the unique ability to measure advanced haemodynamic parameters such as turbulent kinetic energy, viscous energy loss rate and wall shear stress, which may add further diagnostic and prognostic information. Although 4D Flow CMR acquisition can take 5–10 min, emerging acceleration techniques can significantly reduce scan times, making 4D Flow CMR applicable in contemporary clinical practice. CONCLUSION: 4D Flow CMR is an emerging CMR technique, which has the potential to become the new reference-standard method for the evaluation of valvular lesions. In this review, we describe the clinical applications, advantages and disadvantages of 4D Flow CMR in the assessment of valvular heart disease. BioMed Central 2022-08-22 /pmc/articles/PMC9394062/ /pubmed/35989320 http://dx.doi.org/10.1186/s12968-022-00882-0 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Review
Gorecka, Miroslawa
Bissell, Malenka M.
Higgins, David M.
Garg, Pankaj
Plein, Sven
Greenwood, John P.
Rationale and clinical applications of 4D flow cardiovascular magnetic resonance in assessment of valvular heart disease: a comprehensive review
title Rationale and clinical applications of 4D flow cardiovascular magnetic resonance in assessment of valvular heart disease: a comprehensive review
title_full Rationale and clinical applications of 4D flow cardiovascular magnetic resonance in assessment of valvular heart disease: a comprehensive review
title_fullStr Rationale and clinical applications of 4D flow cardiovascular magnetic resonance in assessment of valvular heart disease: a comprehensive review
title_full_unstemmed Rationale and clinical applications of 4D flow cardiovascular magnetic resonance in assessment of valvular heart disease: a comprehensive review
title_short Rationale and clinical applications of 4D flow cardiovascular magnetic resonance in assessment of valvular heart disease: a comprehensive review
title_sort rationale and clinical applications of 4d flow cardiovascular magnetic resonance in assessment of valvular heart disease: a comprehensive review
topic Review
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9394062/
https://www.ncbi.nlm.nih.gov/pubmed/35989320
http://dx.doi.org/10.1186/s12968-022-00882-0
work_keys_str_mv AT goreckamiroslawa rationaleandclinicalapplicationsof4dflowcardiovascularmagneticresonanceinassessmentofvalvularheartdiseaseacomprehensivereview
AT bissellmalenkam rationaleandclinicalapplicationsof4dflowcardiovascularmagneticresonanceinassessmentofvalvularheartdiseaseacomprehensivereview
AT higginsdavidm rationaleandclinicalapplicationsof4dflowcardiovascularmagneticresonanceinassessmentofvalvularheartdiseaseacomprehensivereview
AT gargpankaj rationaleandclinicalapplicationsof4dflowcardiovascularmagneticresonanceinassessmentofvalvularheartdiseaseacomprehensivereview
AT pleinsven rationaleandclinicalapplicationsof4dflowcardiovascularmagneticresonanceinassessmentofvalvularheartdiseaseacomprehensivereview
AT greenwoodjohnp rationaleandclinicalapplicationsof4dflowcardiovascularmagneticresonanceinassessmentofvalvularheartdiseaseacomprehensivereview