Cargando…
Intrasaccular Flow Disruptor-Assisted Coiling of Intracranial Aneurysms Using the Novel Contour Neurovascular Systems and NEQSTENT: A Single-Center Safety and Feasibility Study
Background: Intrasaccular flow disruptors (IFD) have been introduced in the treatment of intracranial aneurysms (IAs) to overcome the low aneurysm occlusion rate and the high recanalization rate of the coiling technique. Among them, the Contour Neurovascular System (CNS) and the Neqstent (NQS) were...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9394360/ https://www.ncbi.nlm.nih.gov/pubmed/35892432 http://dx.doi.org/10.3390/brainsci12080991 |
_version_ | 1784771473581277184 |
---|---|
author | Diana, Francesco de Dios Lascuevas, Marta Peschillo, Simone Raz, Eytan Yoshimura, Shinichi Requena Ruiz, Manuel Hernández Morales, David Tomasello, Alejandro |
author_facet | Diana, Francesco de Dios Lascuevas, Marta Peschillo, Simone Raz, Eytan Yoshimura, Shinichi Requena Ruiz, Manuel Hernández Morales, David Tomasello, Alejandro |
author_sort | Diana, Francesco |
collection | PubMed |
description | Background: Intrasaccular flow disruptors (IFD) have been introduced in the treatment of intracranial aneurysms (IAs) to overcome the low aneurysm occlusion rate and the high recanalization rate of the coiling technique. Among them, the Contour Neurovascular System (CNS) and the Neqstent (NQS) were designed to reconstruct the aneurysmal neck and both can be used as assisting coiling devices. We aimed to report our preliminary experience with the flow disruptor-assisted coiling (IFD-AC) technique. Methods: We performed a retrospective analysis of prospectively collected data of all patients with IAs treated with the IFD-AC. Results: Between February 2021 and April 2022, we treated 15 IAs with the IFD-AC: 10 ruptured and 5 unruptured. The IFD-AC was successfully performed in 13 cases, with a post-operative RROC 1 in 12 cases (92.3%) and RROC 2 in 1 case (7.7%). There was one ischemic event (6.7%) and no hemorrhagic complications. Twelve patients underwent a mid-term radiologic follow-up: Ten IAs (83.4%) presented an adequate occlusion, while 2 (16.7%) had a recurrence. Conclusions: The IFD-AC, both with the CNS and the NQS, seems a safe technique with promising efficacy profile. The IFD-AC has proved to be safe without antiplatelet therapy in ruptured cases. Further studies are needed to confirm our preliminary results. |
format | Online Article Text |
id | pubmed-9394360 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-93943602022-08-23 Intrasaccular Flow Disruptor-Assisted Coiling of Intracranial Aneurysms Using the Novel Contour Neurovascular Systems and NEQSTENT: A Single-Center Safety and Feasibility Study Diana, Francesco de Dios Lascuevas, Marta Peschillo, Simone Raz, Eytan Yoshimura, Shinichi Requena Ruiz, Manuel Hernández Morales, David Tomasello, Alejandro Brain Sci Article Background: Intrasaccular flow disruptors (IFD) have been introduced in the treatment of intracranial aneurysms (IAs) to overcome the low aneurysm occlusion rate and the high recanalization rate of the coiling technique. Among them, the Contour Neurovascular System (CNS) and the Neqstent (NQS) were designed to reconstruct the aneurysmal neck and both can be used as assisting coiling devices. We aimed to report our preliminary experience with the flow disruptor-assisted coiling (IFD-AC) technique. Methods: We performed a retrospective analysis of prospectively collected data of all patients with IAs treated with the IFD-AC. Results: Between February 2021 and April 2022, we treated 15 IAs with the IFD-AC: 10 ruptured and 5 unruptured. The IFD-AC was successfully performed in 13 cases, with a post-operative RROC 1 in 12 cases (92.3%) and RROC 2 in 1 case (7.7%). There was one ischemic event (6.7%) and no hemorrhagic complications. Twelve patients underwent a mid-term radiologic follow-up: Ten IAs (83.4%) presented an adequate occlusion, while 2 (16.7%) had a recurrence. Conclusions: The IFD-AC, both with the CNS and the NQS, seems a safe technique with promising efficacy profile. The IFD-AC has proved to be safe without antiplatelet therapy in ruptured cases. Further studies are needed to confirm our preliminary results. MDPI 2022-07-26 /pmc/articles/PMC9394360/ /pubmed/35892432 http://dx.doi.org/10.3390/brainsci12080991 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Diana, Francesco de Dios Lascuevas, Marta Peschillo, Simone Raz, Eytan Yoshimura, Shinichi Requena Ruiz, Manuel Hernández Morales, David Tomasello, Alejandro Intrasaccular Flow Disruptor-Assisted Coiling of Intracranial Aneurysms Using the Novel Contour Neurovascular Systems and NEQSTENT: A Single-Center Safety and Feasibility Study |
title | Intrasaccular Flow Disruptor-Assisted Coiling of Intracranial Aneurysms Using the Novel Contour Neurovascular Systems and NEQSTENT: A Single-Center Safety and Feasibility Study |
title_full | Intrasaccular Flow Disruptor-Assisted Coiling of Intracranial Aneurysms Using the Novel Contour Neurovascular Systems and NEQSTENT: A Single-Center Safety and Feasibility Study |
title_fullStr | Intrasaccular Flow Disruptor-Assisted Coiling of Intracranial Aneurysms Using the Novel Contour Neurovascular Systems and NEQSTENT: A Single-Center Safety and Feasibility Study |
title_full_unstemmed | Intrasaccular Flow Disruptor-Assisted Coiling of Intracranial Aneurysms Using the Novel Contour Neurovascular Systems and NEQSTENT: A Single-Center Safety and Feasibility Study |
title_short | Intrasaccular Flow Disruptor-Assisted Coiling of Intracranial Aneurysms Using the Novel Contour Neurovascular Systems and NEQSTENT: A Single-Center Safety and Feasibility Study |
title_sort | intrasaccular flow disruptor-assisted coiling of intracranial aneurysms using the novel contour neurovascular systems and neqstent: a single-center safety and feasibility study |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9394360/ https://www.ncbi.nlm.nih.gov/pubmed/35892432 http://dx.doi.org/10.3390/brainsci12080991 |
work_keys_str_mv | AT dianafrancesco intrasaccularflowdisruptorassistedcoilingofintracranialaneurysmsusingthenovelcontourneurovascularsystemsandneqstentasinglecentersafetyandfeasibilitystudy AT dedioslascuevasmarta intrasaccularflowdisruptorassistedcoilingofintracranialaneurysmsusingthenovelcontourneurovascularsystemsandneqstentasinglecentersafetyandfeasibilitystudy AT peschillosimone intrasaccularflowdisruptorassistedcoilingofintracranialaneurysmsusingthenovelcontourneurovascularsystemsandneqstentasinglecentersafetyandfeasibilitystudy AT razeytan intrasaccularflowdisruptorassistedcoilingofintracranialaneurysmsusingthenovelcontourneurovascularsystemsandneqstentasinglecentersafetyandfeasibilitystudy AT yoshimurashinichi intrasaccularflowdisruptorassistedcoilingofintracranialaneurysmsusingthenovelcontourneurovascularsystemsandneqstentasinglecentersafetyandfeasibilitystudy AT requenaruizmanuel intrasaccularflowdisruptorassistedcoilingofintracranialaneurysmsusingthenovelcontourneurovascularsystemsandneqstentasinglecentersafetyandfeasibilitystudy AT hernandezmoralesdavid intrasaccularflowdisruptorassistedcoilingofintracranialaneurysmsusingthenovelcontourneurovascularsystemsandneqstentasinglecentersafetyandfeasibilitystudy AT tomaselloalejandro intrasaccularflowdisruptorassistedcoilingofintracranialaneurysmsusingthenovelcontourneurovascularsystemsandneqstentasinglecentersafetyandfeasibilitystudy |