Implementation Strategy for Highly-Coordinated Cochlear Implant Care With Remote Programming: The Complete Cochlear Implant Care Model

To introduce and discuss implementation strategy for the Complete Cochlear Implant Care (CCIC) model, a highly-coordinated cochlear implant (CI) care delivery model requiring a single on-site visit for preoperative workup, surgery, and postoperative programming. STUDY DESIGN: Prospective, nonrandomi...

Descripción completa

Detalles Bibliográficos
Autores principales: Nassiri, Ashley M., Saoji, Aniket A., DeJong, Melissa D., Tombers, Nicole M., Driscoll, Colin L. W., Neff, Brian A., Haynes, David S., Carlson, Matthew L.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Lippincott Williams & Wilkins 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9394487/
https://www.ncbi.nlm.nih.gov/pubmed/35970171
http://dx.doi.org/10.1097/MAO.0000000000003644
Descripción
Sumario:To introduce and discuss implementation strategy for the Complete Cochlear Implant Care (CCIC) model, a highly-coordinated cochlear implant (CI) care delivery model requiring a single on-site visit for preoperative workup, surgery, and postoperative programming. STUDY DESIGN: Prospective, nonrandomized, two-arm clinical trial. SETTING: Tertiary referral CI center. PATIENTS: Adults who meet audiologic criteria for cochlear implantation. INTERVENTIONS: Cochlear implantation, coordinated care delivery, including remote programming. MAIN OUTCOME MEASURES: Care delivery model feasibility and process implementation. RESULTS: Patients determined to be likely CI candidates based on routine audiometry are eligible for enrollment. The CCIC model uses telemedicine and electronic educational materials to prepare patients for same-day on-site consultation with CI surgery, same or next-day activation, and postoperative remote programming for 12 months. Implementation challenges include overcoming inertia related to the implementation of a new clinical workflow, whereas scalability of the CCIC model is limited by current hardware requirements for remote programming technology. A dedicated CCIC process coordinator is critical for overcoming obstacles in implementation and process improvement through feedback and iterative changes. Team and patient-facing materials are included and should be tailored to fit each unique CI program looking to implement CCIC. CONCLUSION: The CCIC model has the potential to dramatically streamline hearing healthcare delivery. Implementation requires an adaptive approach, as obstacles may vary according to institutional infrastructure and policies.