Cargando…

An evaluation of the use of EBT-XD film for SRS/SBRT commissioning of a 1.5 Tesla MR-Linac system

PURPOSE: The goal of this study was to evaluate the use of EBT-XD film for SRS/SBRT commissioning in a 1.5T hybrid MR-Linac (MRL). METHOD: The output factors (S(t)), from 1x1, 2x2, 3x3 cm(2), were measured with film in solid water. The results were compared with (1) the measurements by a PTW diamond...

Descripción completa

Detalles Bibliográficos
Autores principales: Lim, Seng Boh, Tyagi, Neelam, Subashi, Ergys, Liang, Jiayi, Chan, Maria
Formato: Online Artículo Texto
Lenguaje:English
Publicado: 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9396448/
https://www.ncbi.nlm.nih.gov/pubmed/35189431
http://dx.doi.org/10.1016/j.ejmp.2022.02.012
_version_ 1784771930638778368
author Lim, Seng Boh
Tyagi, Neelam
Subashi, Ergys
Liang, Jiayi
Chan, Maria
author_facet Lim, Seng Boh
Tyagi, Neelam
Subashi, Ergys
Liang, Jiayi
Chan, Maria
author_sort Lim, Seng Boh
collection PubMed
description PURPOSE: The goal of this study was to evaluate the use of EBT-XD film for SRS/SBRT commissioning in a 1.5T hybrid MR-Linac (MRL). METHOD: The output factors (S(t)), from 1x1, 2x2, 3x3 cm(2), were measured with film in solid water. The results were compared with (1) the measurements by a PTW diamond detector (CVD) and an Exradin® A26MR ion chamber in 3D water phantom; (2) Monte Carlo calculation by Monaco TPS (MTPS) in water. The inline (IN) and crossline (CR) profiles, measured by films and the CVD, were also compared. An SRS plan with two targets was created in MTPS and was measured with EBT-XD film in a StereoPHAN™ phantom serving as an end-to-end test. The 3x3 cm(2) was used for film calibration with doses ranging from 0 to 28 Gy. Water was added to the phantom-film-phantom interface to reduce the electron-return-effect (ERE). Films were calibrated with One-scan-dosimetry protocol. RESULTS: The film S(t) were within 1.2% and 2.2% compared to other detectors and MTPS respectively. At the central B-field induced asymmetric region, films were within 0.6% between the CVD and the MTPS, but 5–8% differences were observed in the 40%-5% gradient region in CR due to ERE. The differences in localization and dose were found to be 0.6 mm and 3.3%. The γ(3%/2mm), γ (5%/2mm), γ (5%/1mm) were 97.7%, 99.3%, 94.6%. CONCLUSIONS: Films can provide accurate dosimetric results under ERE and are valuable for commissioning MRL. Using the One-scan-dosimetry protocol with EBT-XD film for MRL increases accuracy and efficiency in commissioning and QA of SRS/SBRT.
format Online
Article
Text
id pubmed-9396448
institution National Center for Biotechnology Information
language English
publishDate 2022
record_format MEDLINE/PubMed
spelling pubmed-93964482022-08-23 An evaluation of the use of EBT-XD film for SRS/SBRT commissioning of a 1.5 Tesla MR-Linac system Lim, Seng Boh Tyagi, Neelam Subashi, Ergys Liang, Jiayi Chan, Maria Phys Med Article PURPOSE: The goal of this study was to evaluate the use of EBT-XD film for SRS/SBRT commissioning in a 1.5T hybrid MR-Linac (MRL). METHOD: The output factors (S(t)), from 1x1, 2x2, 3x3 cm(2), were measured with film in solid water. The results were compared with (1) the measurements by a PTW diamond detector (CVD) and an Exradin® A26MR ion chamber in 3D water phantom; (2) Monte Carlo calculation by Monaco TPS (MTPS) in water. The inline (IN) and crossline (CR) profiles, measured by films and the CVD, were also compared. An SRS plan with two targets was created in MTPS and was measured with EBT-XD film in a StereoPHAN™ phantom serving as an end-to-end test. The 3x3 cm(2) was used for film calibration with doses ranging from 0 to 28 Gy. Water was added to the phantom-film-phantom interface to reduce the electron-return-effect (ERE). Films were calibrated with One-scan-dosimetry protocol. RESULTS: The film S(t) were within 1.2% and 2.2% compared to other detectors and MTPS respectively. At the central B-field induced asymmetric region, films were within 0.6% between the CVD and the MTPS, but 5–8% differences were observed in the 40%-5% gradient region in CR due to ERE. The differences in localization and dose were found to be 0.6 mm and 3.3%. The γ(3%/2mm), γ (5%/2mm), γ (5%/1mm) were 97.7%, 99.3%, 94.6%. CONCLUSIONS: Films can provide accurate dosimetric results under ERE and are valuable for commissioning MRL. Using the One-scan-dosimetry protocol with EBT-XD film for MRL increases accuracy and efficiency in commissioning and QA of SRS/SBRT. 2022-04 2022-02-18 /pmc/articles/PMC9396448/ /pubmed/35189431 http://dx.doi.org/10.1016/j.ejmp.2022.02.012 Text en https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/ (https://creativecommons.org/licenses/by-nc-nd/4.0/) ).
spellingShingle Article
Lim, Seng Boh
Tyagi, Neelam
Subashi, Ergys
Liang, Jiayi
Chan, Maria
An evaluation of the use of EBT-XD film for SRS/SBRT commissioning of a 1.5 Tesla MR-Linac system
title An evaluation of the use of EBT-XD film for SRS/SBRT commissioning of a 1.5 Tesla MR-Linac system
title_full An evaluation of the use of EBT-XD film for SRS/SBRT commissioning of a 1.5 Tesla MR-Linac system
title_fullStr An evaluation of the use of EBT-XD film for SRS/SBRT commissioning of a 1.5 Tesla MR-Linac system
title_full_unstemmed An evaluation of the use of EBT-XD film for SRS/SBRT commissioning of a 1.5 Tesla MR-Linac system
title_short An evaluation of the use of EBT-XD film for SRS/SBRT commissioning of a 1.5 Tesla MR-Linac system
title_sort evaluation of the use of ebt-xd film for srs/sbrt commissioning of a 1.5 tesla mr-linac system
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9396448/
https://www.ncbi.nlm.nih.gov/pubmed/35189431
http://dx.doi.org/10.1016/j.ejmp.2022.02.012
work_keys_str_mv AT limsengboh anevaluationoftheuseofebtxdfilmforsrssbrtcommissioningofa15teslamrlinacsystem
AT tyagineelam anevaluationoftheuseofebtxdfilmforsrssbrtcommissioningofa15teslamrlinacsystem
AT subashiergys anevaluationoftheuseofebtxdfilmforsrssbrtcommissioningofa15teslamrlinacsystem
AT liangjiayi anevaluationoftheuseofebtxdfilmforsrssbrtcommissioningofa15teslamrlinacsystem
AT chanmaria anevaluationoftheuseofebtxdfilmforsrssbrtcommissioningofa15teslamrlinacsystem
AT limsengboh evaluationoftheuseofebtxdfilmforsrssbrtcommissioningofa15teslamrlinacsystem
AT tyagineelam evaluationoftheuseofebtxdfilmforsrssbrtcommissioningofa15teslamrlinacsystem
AT subashiergys evaluationoftheuseofebtxdfilmforsrssbrtcommissioningofa15teslamrlinacsystem
AT liangjiayi evaluationoftheuseofebtxdfilmforsrssbrtcommissioningofa15teslamrlinacsystem
AT chanmaria evaluationoftheuseofebtxdfilmforsrssbrtcommissioningofa15teslamrlinacsystem