Cargando…

Are in Person and Telephone Interviews Equivalent Modes of Administrating the CAT, the FACIT-FS and the SGRQ in People With COPD?

Background: The COVID-19 pandemic brought numerous challenges, namely in routine assessment of people with chronic obstructive pulmonary disease (COPD). The COPD Assessment Test (CAT), the Functional Assessment of Chronic Illness-Fatigue-Subscale (FACIT-FS) and the St. George's respiratory ques...

Descripción completa

Detalles Bibliográficos
Autores principales: Rocha, Vânia, Jácome, Cristina, Martins, Vitória, Marques, Alda
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9397839/
https://www.ncbi.nlm.nih.gov/pubmed/36188865
http://dx.doi.org/10.3389/fresc.2021.729190
_version_ 1784772208555458560
author Rocha, Vânia
Jácome, Cristina
Martins, Vitória
Marques, Alda
author_facet Rocha, Vânia
Jácome, Cristina
Martins, Vitória
Marques, Alda
author_sort Rocha, Vânia
collection PubMed
description Background: The COVID-19 pandemic brought numerous challenges, namely in routine assessment of people with chronic obstructive pulmonary disease (COPD). The COPD Assessment Test (CAT), the Functional Assessment of Chronic Illness-Fatigue-Subscale (FACIT-FS) and the St. George's respiratory questionnaire (SGRQ) are important patient-reported outcome measures used to assess people with COPD, but its face-to-face application has been compromised. The telephone interview offers a simple and effective alternative, yet uncertainty regarding its equivalence remains. This study aimed to establish the reliability and validity of the CAT, the FACIT-FS and the SGRQ administered by telephone interview in people with COPD. Methods: Data from an observational prospective study including people with COPD were analyzed. Participants answered to the CAT, FACIT-FS and SGRQ questionnaires in person and by telephone, with a maximum interval of 48-h. Participants were randomly selected to answer first to the in-person questionnaire followed by telephone or vice versa. Reliability measures included internal consistency with Cronbach's alpha, test-retest reliability with the intraclass correlation coefficient (ICC(2,1)), test-retest measurement error with the standard error of measurement (SEM) and agreement with the Bland and Altman 95% limits of agreement. Validity was assessed with the Spearman correlation (rho). Results: Fifty-five people with COPD (44 men; 68.1 ± 7.9 years; FEV(1): 59.1 ± 20.3% predicted) were included. Similar internal consistency was observed between in person vs. telephone interview for the CAT (0.82 vs. 0.84), the FACIT-FS (0.83 vs. 0.84) and the SGRQ (0.92 vs. 0.93). Test-retest reliability was excellent, with an ICC(2,1) of 0.77 (95% CI: 0.65; 0.86), 0.86 (95% CI: 0.77; 0.92) and 0.94 (95% CI: 0.90; 0.96) for the CAT, FACIT-FS and SGRQ total scores, respectively. The SEM showed a low level of associated measurement error and the Bland and Altman plots illustrated a good level of agreement between both modes of administration, with no evidence of systematic bias. Robust positive correlations (rho 0.87–0.94, p < 0.001) were found for the CAT, FACIT-FS and SGRQ total scores applied by both methods. Conclusion: The telephonic administration of the CAT, the FACIT-FS and the SGRQ are a valid and reliable alternative approach to in person interviews for monitoring symptoms and health-related quality of life in people with COPD. The telephone might be an important add-on for personalized assessment and management of COPD thru remote monitoring.
format Online
Article
Text
id pubmed-9397839
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-93978392022-09-29 Are in Person and Telephone Interviews Equivalent Modes of Administrating the CAT, the FACIT-FS and the SGRQ in People With COPD? Rocha, Vânia Jácome, Cristina Martins, Vitória Marques, Alda Front Rehabil Sci Rehabilitation Sciences Background: The COVID-19 pandemic brought numerous challenges, namely in routine assessment of people with chronic obstructive pulmonary disease (COPD). The COPD Assessment Test (CAT), the Functional Assessment of Chronic Illness-Fatigue-Subscale (FACIT-FS) and the St. George's respiratory questionnaire (SGRQ) are important patient-reported outcome measures used to assess people with COPD, but its face-to-face application has been compromised. The telephone interview offers a simple and effective alternative, yet uncertainty regarding its equivalence remains. This study aimed to establish the reliability and validity of the CAT, the FACIT-FS and the SGRQ administered by telephone interview in people with COPD. Methods: Data from an observational prospective study including people with COPD were analyzed. Participants answered to the CAT, FACIT-FS and SGRQ questionnaires in person and by telephone, with a maximum interval of 48-h. Participants were randomly selected to answer first to the in-person questionnaire followed by telephone or vice versa. Reliability measures included internal consistency with Cronbach's alpha, test-retest reliability with the intraclass correlation coefficient (ICC(2,1)), test-retest measurement error with the standard error of measurement (SEM) and agreement with the Bland and Altman 95% limits of agreement. Validity was assessed with the Spearman correlation (rho). Results: Fifty-five people with COPD (44 men; 68.1 ± 7.9 years; FEV(1): 59.1 ± 20.3% predicted) were included. Similar internal consistency was observed between in person vs. telephone interview for the CAT (0.82 vs. 0.84), the FACIT-FS (0.83 vs. 0.84) and the SGRQ (0.92 vs. 0.93). Test-retest reliability was excellent, with an ICC(2,1) of 0.77 (95% CI: 0.65; 0.86), 0.86 (95% CI: 0.77; 0.92) and 0.94 (95% CI: 0.90; 0.96) for the CAT, FACIT-FS and SGRQ total scores, respectively. The SEM showed a low level of associated measurement error and the Bland and Altman plots illustrated a good level of agreement between both modes of administration, with no evidence of systematic bias. Robust positive correlations (rho 0.87–0.94, p < 0.001) were found for the CAT, FACIT-FS and SGRQ total scores applied by both methods. Conclusion: The telephonic administration of the CAT, the FACIT-FS and the SGRQ are a valid and reliable alternative approach to in person interviews for monitoring symptoms and health-related quality of life in people with COPD. The telephone might be an important add-on for personalized assessment and management of COPD thru remote monitoring. Frontiers Media S.A. 2021-10-25 /pmc/articles/PMC9397839/ /pubmed/36188865 http://dx.doi.org/10.3389/fresc.2021.729190 Text en Copyright © 2021 Rocha, Jácome, Martins and Marques. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Rehabilitation Sciences
Rocha, Vânia
Jácome, Cristina
Martins, Vitória
Marques, Alda
Are in Person and Telephone Interviews Equivalent Modes of Administrating the CAT, the FACIT-FS and the SGRQ in People With COPD?
title Are in Person and Telephone Interviews Equivalent Modes of Administrating the CAT, the FACIT-FS and the SGRQ in People With COPD?
title_full Are in Person and Telephone Interviews Equivalent Modes of Administrating the CAT, the FACIT-FS and the SGRQ in People With COPD?
title_fullStr Are in Person and Telephone Interviews Equivalent Modes of Administrating the CAT, the FACIT-FS and the SGRQ in People With COPD?
title_full_unstemmed Are in Person and Telephone Interviews Equivalent Modes of Administrating the CAT, the FACIT-FS and the SGRQ in People With COPD?
title_short Are in Person and Telephone Interviews Equivalent Modes of Administrating the CAT, the FACIT-FS and the SGRQ in People With COPD?
title_sort are in person and telephone interviews equivalent modes of administrating the cat, the facit-fs and the sgrq in people with copd?
topic Rehabilitation Sciences
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9397839/
https://www.ncbi.nlm.nih.gov/pubmed/36188865
http://dx.doi.org/10.3389/fresc.2021.729190
work_keys_str_mv AT rochavania areinpersonandtelephoneinterviewsequivalentmodesofadministratingthecatthefacitfsandthesgrqinpeoplewithcopd
AT jacomecristina areinpersonandtelephoneinterviewsequivalentmodesofadministratingthecatthefacitfsandthesgrqinpeoplewithcopd
AT martinsvitoria areinpersonandtelephoneinterviewsequivalentmodesofadministratingthecatthefacitfsandthesgrqinpeoplewithcopd
AT marquesalda areinpersonandtelephoneinterviewsequivalentmodesofadministratingthecatthefacitfsandthesgrqinpeoplewithcopd