Clinical Application of Quantitative CT Technique in Assessing Liver Fat Content in Patients with Schizophrenia

This paper investigates the clinical application value of quantitative CT (QCT) technique in evaluating liver fat content in patients with schizophrenia. 457 patients with schizophrenia underwent abdominal CT and QCT scans. QCT postprocessing software (QCT Pro version 6.1) measures the percentage of...

Descripción completa

Detalles Bibliográficos
Autores principales: Han, Mengyang, Lin, Yilian, Chen, Hong, Hua, Fang, Zhang, Jianye, Wang, Jinhong
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9398828/
https://www.ncbi.nlm.nih.gov/pubmed/36072632
http://dx.doi.org/10.1155/2022/7006133
_version_ 1784772401654923264
author Han, Mengyang
Lin, Yilian
Chen, Hong
Hua, Fang
Zhang, Jianye
Wang, Jinhong
author_facet Han, Mengyang
Lin, Yilian
Chen, Hong
Hua, Fang
Zhang, Jianye
Wang, Jinhong
author_sort Han, Mengyang
collection PubMed
description This paper investigates the clinical application value of quantitative CT (QCT) technique in evaluating liver fat content in patients with schizophrenia. 457 patients with schizophrenia underwent abdominal CT and QCT scans. QCT postprocessing software (QCT Pro version 6.1) measures the percentage of liver fat content in all patients and calculates the average value. Then, the CT workstation displays the corresponding liver/spleen CT value ratio. SPSS 25.0 software is used for statistical analysis of data, and the correlation coefficient between the mean liver fat content. The ratio of liver/spleen CT values is calculated and the consistency between the results is compared. The ROC curve is used to define the cutoff value of the target and evaluate its diagnostic efficiency. There is a high negative correlation between the mean liver fat content and the ratio of liver/spleen CT value in all schizophrenia patients (r = −0.935, P < 0.05). The identification rate of patients with mild fatty liver by QCT technology is 4 times higher than that of the liver and spleen CT value ratio (50.98% Vs 12.47%). Taking the ratio of the liver to the spleen as the standard, the ROC curve of the liver fat content in QCT is drawn, the cutoff values of the mean liver fat content of the normal liver and mild fatty liver and mild and moderate fatty liver were 9.35% and 19.4%, respectively. Comparing this result with the results obtained by the existing QCT for the fatty liver diagnosis and grading standard value (American standard) shows that there is a difference of about 5% between the two. Compared with the semiquantitative liver/spleen ratio, QCT technology can quantify the liver fat content. Given the particularity of patients with schizophrenia, QCT can be used as an important test for identifying early fatty liver and assessing the severity of fatty liver.
format Online
Article
Text
id pubmed-9398828
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-93988282022-09-06 Clinical Application of Quantitative CT Technique in Assessing Liver Fat Content in Patients with Schizophrenia Han, Mengyang Lin, Yilian Chen, Hong Hua, Fang Zhang, Jianye Wang, Jinhong Contrast Media Mol Imaging Research Article This paper investigates the clinical application value of quantitative CT (QCT) technique in evaluating liver fat content in patients with schizophrenia. 457 patients with schizophrenia underwent abdominal CT and QCT scans. QCT postprocessing software (QCT Pro version 6.1) measures the percentage of liver fat content in all patients and calculates the average value. Then, the CT workstation displays the corresponding liver/spleen CT value ratio. SPSS 25.0 software is used for statistical analysis of data, and the correlation coefficient between the mean liver fat content. The ratio of liver/spleen CT values is calculated and the consistency between the results is compared. The ROC curve is used to define the cutoff value of the target and evaluate its diagnostic efficiency. There is a high negative correlation between the mean liver fat content and the ratio of liver/spleen CT value in all schizophrenia patients (r = −0.935, P < 0.05). The identification rate of patients with mild fatty liver by QCT technology is 4 times higher than that of the liver and spleen CT value ratio (50.98% Vs 12.47%). Taking the ratio of the liver to the spleen as the standard, the ROC curve of the liver fat content in QCT is drawn, the cutoff values of the mean liver fat content of the normal liver and mild fatty liver and mild and moderate fatty liver were 9.35% and 19.4%, respectively. Comparing this result with the results obtained by the existing QCT for the fatty liver diagnosis and grading standard value (American standard) shows that there is a difference of about 5% between the two. Compared with the semiquantitative liver/spleen ratio, QCT technology can quantify the liver fat content. Given the particularity of patients with schizophrenia, QCT can be used as an important test for identifying early fatty liver and assessing the severity of fatty liver. Hindawi 2022-08-16 /pmc/articles/PMC9398828/ /pubmed/36072632 http://dx.doi.org/10.1155/2022/7006133 Text en Copyright © 2022 Mengyang Han et al. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Han, Mengyang
Lin, Yilian
Chen, Hong
Hua, Fang
Zhang, Jianye
Wang, Jinhong
Clinical Application of Quantitative CT Technique in Assessing Liver Fat Content in Patients with Schizophrenia
title Clinical Application of Quantitative CT Technique in Assessing Liver Fat Content in Patients with Schizophrenia
title_full Clinical Application of Quantitative CT Technique in Assessing Liver Fat Content in Patients with Schizophrenia
title_fullStr Clinical Application of Quantitative CT Technique in Assessing Liver Fat Content in Patients with Schizophrenia
title_full_unstemmed Clinical Application of Quantitative CT Technique in Assessing Liver Fat Content in Patients with Schizophrenia
title_short Clinical Application of Quantitative CT Technique in Assessing Liver Fat Content in Patients with Schizophrenia
title_sort clinical application of quantitative ct technique in assessing liver fat content in patients with schizophrenia
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9398828/
https://www.ncbi.nlm.nih.gov/pubmed/36072632
http://dx.doi.org/10.1155/2022/7006133
work_keys_str_mv AT hanmengyang clinicalapplicationofquantitativecttechniqueinassessingliverfatcontentinpatientswithschizophrenia
AT linyilian clinicalapplicationofquantitativecttechniqueinassessingliverfatcontentinpatientswithschizophrenia
AT chenhong clinicalapplicationofquantitativecttechniqueinassessingliverfatcontentinpatientswithschizophrenia
AT huafang clinicalapplicationofquantitativecttechniqueinassessingliverfatcontentinpatientswithschizophrenia
AT zhangjianye clinicalapplicationofquantitativecttechniqueinassessingliverfatcontentinpatientswithschizophrenia
AT wangjinhong clinicalapplicationofquantitativecttechniqueinassessingliverfatcontentinpatientswithschizophrenia