Artificial Intelligence Algorithm-Based MRI in the Diagnosis of Complications after Renal Transplantation
This study was to explore the diagnostic value of magnetic resonance imaging (MRI) optimized by residual segmentation attention dual channel network (DRSA-U-Net) in the diagnosis of complications after renal transplantation and to provide a more effective examination method for clinic. 89 patients w...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9398844/ https://www.ncbi.nlm.nih.gov/pubmed/36072641 http://dx.doi.org/10.1155/2022/8930584 |
_version_ | 1784772405600714752 |
---|---|
author | Liu, Hang Ren, Liang Fan, Bohan Wang, Wei Hu, Xiaopeng Zhang, Xiaodong |
author_facet | Liu, Hang Ren, Liang Fan, Bohan Wang, Wei Hu, Xiaopeng Zhang, Xiaodong |
author_sort | Liu, Hang |
collection | PubMed |
description | This study was to explore the diagnostic value of magnetic resonance imaging (MRI) optimized by residual segmentation attention dual channel network (DRSA-U-Net) in the diagnosis of complications after renal transplantation and to provide a more effective examination method for clinic. 89 patients with renal transplantation were selected retrospectively, and all underwent MRI. The patients were divided into control group (conventional MRI image diagnosis) and observation group (MRI image diagnosis based on DRSA-U-Net). The accuracy of MRI images in the two groups was evaluated according to the comprehensive diagnostic results. The root mean square error (RMSE) and peak signal-to-noise ratio (PSNR) of DRSA-U-Net on T1WI and T2WI sequences were better than those of U-Net and dense U-Net (P < 0.05); comprehensive examination showed that 39 patients had obstruction between ureter and bladder anastomosis, 13 cases had rejection, 10 cases had perirenal hematoma, 5 cases had renal infarction, and 22 cases had no complications; the diagnostic sensitivity, specificity, accuracy, and consistency of the observation group were higher than those of the control group (P < 0.05). In the control group, the sensitivity, specificity, and accuracy in the diagnosis of complications after renal transplantation were 66.5%, 84.1%, and 78.32%, respectively; in the observation group, the sensitivity, specificity, and accuracy in the diagnosis were 67.8%, 86.7%, and 80.6%, respectively. DRSA-U-Net denoising algorithm can clearly display the information of MRI images on the kidney, ureter, and surrounding tissues, improve its diagnostic accuracy in complications after renal transplantation, and has good clinical application value. |
format | Online Article Text |
id | pubmed-9398844 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Hindawi |
record_format | MEDLINE/PubMed |
spelling | pubmed-93988442022-09-06 Artificial Intelligence Algorithm-Based MRI in the Diagnosis of Complications after Renal Transplantation Liu, Hang Ren, Liang Fan, Bohan Wang, Wei Hu, Xiaopeng Zhang, Xiaodong Contrast Media Mol Imaging Research Article This study was to explore the diagnostic value of magnetic resonance imaging (MRI) optimized by residual segmentation attention dual channel network (DRSA-U-Net) in the diagnosis of complications after renal transplantation and to provide a more effective examination method for clinic. 89 patients with renal transplantation were selected retrospectively, and all underwent MRI. The patients were divided into control group (conventional MRI image diagnosis) and observation group (MRI image diagnosis based on DRSA-U-Net). The accuracy of MRI images in the two groups was evaluated according to the comprehensive diagnostic results. The root mean square error (RMSE) and peak signal-to-noise ratio (PSNR) of DRSA-U-Net on T1WI and T2WI sequences were better than those of U-Net and dense U-Net (P < 0.05); comprehensive examination showed that 39 patients had obstruction between ureter and bladder anastomosis, 13 cases had rejection, 10 cases had perirenal hematoma, 5 cases had renal infarction, and 22 cases had no complications; the diagnostic sensitivity, specificity, accuracy, and consistency of the observation group were higher than those of the control group (P < 0.05). In the control group, the sensitivity, specificity, and accuracy in the diagnosis of complications after renal transplantation were 66.5%, 84.1%, and 78.32%, respectively; in the observation group, the sensitivity, specificity, and accuracy in the diagnosis were 67.8%, 86.7%, and 80.6%, respectively. DRSA-U-Net denoising algorithm can clearly display the information of MRI images on the kidney, ureter, and surrounding tissues, improve its diagnostic accuracy in complications after renal transplantation, and has good clinical application value. Hindawi 2022-08-16 /pmc/articles/PMC9398844/ /pubmed/36072641 http://dx.doi.org/10.1155/2022/8930584 Text en Copyright © 2022 Hang Liu et al. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Liu, Hang Ren, Liang Fan, Bohan Wang, Wei Hu, Xiaopeng Zhang, Xiaodong Artificial Intelligence Algorithm-Based MRI in the Diagnosis of Complications after Renal Transplantation |
title | Artificial Intelligence Algorithm-Based MRI in the Diagnosis of Complications after Renal Transplantation |
title_full | Artificial Intelligence Algorithm-Based MRI in the Diagnosis of Complications after Renal Transplantation |
title_fullStr | Artificial Intelligence Algorithm-Based MRI in the Diagnosis of Complications after Renal Transplantation |
title_full_unstemmed | Artificial Intelligence Algorithm-Based MRI in the Diagnosis of Complications after Renal Transplantation |
title_short | Artificial Intelligence Algorithm-Based MRI in the Diagnosis of Complications after Renal Transplantation |
title_sort | artificial intelligence algorithm-based mri in the diagnosis of complications after renal transplantation |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9398844/ https://www.ncbi.nlm.nih.gov/pubmed/36072641 http://dx.doi.org/10.1155/2022/8930584 |
work_keys_str_mv | AT liuhang artificialintelligencealgorithmbasedmriinthediagnosisofcomplicationsafterrenaltransplantation AT renliang artificialintelligencealgorithmbasedmriinthediagnosisofcomplicationsafterrenaltransplantation AT fanbohan artificialintelligencealgorithmbasedmriinthediagnosisofcomplicationsafterrenaltransplantation AT wangwei artificialintelligencealgorithmbasedmriinthediagnosisofcomplicationsafterrenaltransplantation AT huxiaopeng artificialintelligencealgorithmbasedmriinthediagnosisofcomplicationsafterrenaltransplantation AT zhangxiaodong artificialintelligencealgorithmbasedmriinthediagnosisofcomplicationsafterrenaltransplantation |