Cargando…

Development of a reliable UHPLC-MS/MS method for simultaneous determination of zearalenone and zearalenone-14-glucoside in various feed products

A reliable ultra-high-performance liquid chromatography–tandem mass spectrometry method (UHPLC-MS/MS) was developed for the simultaneous determination of two mycotoxins, that is, zearalenone (ZEN) and zearalenone-14-glucoside (ZEN-14G) in formula feed, concentrated feed, and premixed feed products....

Descripción completa

Detalles Bibliográficos
Autores principales: Zhang, Zhiqi, Cai, Yaling, Fan, Kai, Huang, Qingwen, Zhao, Xiuying, Cao, Haojie, Zhao, Zhihui, Tangni, Emmanuel K., Han, Zheng
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9399508/
https://www.ncbi.nlm.nih.gov/pubmed/36034652
http://dx.doi.org/10.3389/fchem.2022.955266
_version_ 1784772537988677632
author Zhang, Zhiqi
Cai, Yaling
Fan, Kai
Huang, Qingwen
Zhao, Xiuying
Cao, Haojie
Zhao, Zhihui
Tangni, Emmanuel K.
Han, Zheng
author_facet Zhang, Zhiqi
Cai, Yaling
Fan, Kai
Huang, Qingwen
Zhao, Xiuying
Cao, Haojie
Zhao, Zhihui
Tangni, Emmanuel K.
Han, Zheng
author_sort Zhang, Zhiqi
collection PubMed
description A reliable ultra-high-performance liquid chromatography–tandem mass spectrometry method (UHPLC-MS/MS) was developed for the simultaneous determination of two mycotoxins, that is, zearalenone (ZEN) and zearalenone-14-glucoside (ZEN-14G) in formula feed, concentrated feed, and premixed feed products. An improved sample pretreatment was achieved with the hydrophilic–lipophilic balance (HLB) cartridges efficiently removing the impurities and enriching the target analytes in different feeds. The critical parameters affecting the performance of the solid-phase extraction (SPE) procedure were carefully optimized, and 20% acetonitrile in water as the loading solution, 50% methanol in water as the washing solvent, and 5 ml of methanol as the elution solvent yielded the optimal purification efficiencies. The established method was thoroughly validated in terms of linearity (R (2) ≥ 0.999), sensitivity (limit of quantification in the range of 0.50–5.00 μg kg(−1)), recovery (89.35 ± 2.67% to 110.93 ± 1.56%), and precision (RSD, 3.00–14.20%), and it was then successfully applied to investigate a total of 60 feed samples. Among them, 50 samples were found to be contaminated with ZEN (an incidence of 83.3%) at levels ranging from 0.63 to 615.24 μg kg(−1), whereas 22 samples were contaminated with ZEN-14G (an incidence of 36.7%) in the range of 0.89–15.31 μg kg(−1). The developed method proved to be a specific and reliable tool for intensive monitoring of ZEN and ZEN-14G in complex feed matrices.
format Online
Article
Text
id pubmed-9399508
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-93995082022-08-25 Development of a reliable UHPLC-MS/MS method for simultaneous determination of zearalenone and zearalenone-14-glucoside in various feed products Zhang, Zhiqi Cai, Yaling Fan, Kai Huang, Qingwen Zhao, Xiuying Cao, Haojie Zhao, Zhihui Tangni, Emmanuel K. Han, Zheng Front Chem Chemistry A reliable ultra-high-performance liquid chromatography–tandem mass spectrometry method (UHPLC-MS/MS) was developed for the simultaneous determination of two mycotoxins, that is, zearalenone (ZEN) and zearalenone-14-glucoside (ZEN-14G) in formula feed, concentrated feed, and premixed feed products. An improved sample pretreatment was achieved with the hydrophilic–lipophilic balance (HLB) cartridges efficiently removing the impurities and enriching the target analytes in different feeds. The critical parameters affecting the performance of the solid-phase extraction (SPE) procedure were carefully optimized, and 20% acetonitrile in water as the loading solution, 50% methanol in water as the washing solvent, and 5 ml of methanol as the elution solvent yielded the optimal purification efficiencies. The established method was thoroughly validated in terms of linearity (R (2) ≥ 0.999), sensitivity (limit of quantification in the range of 0.50–5.00 μg kg(−1)), recovery (89.35 ± 2.67% to 110.93 ± 1.56%), and precision (RSD, 3.00–14.20%), and it was then successfully applied to investigate a total of 60 feed samples. Among them, 50 samples were found to be contaminated with ZEN (an incidence of 83.3%) at levels ranging from 0.63 to 615.24 μg kg(−1), whereas 22 samples were contaminated with ZEN-14G (an incidence of 36.7%) in the range of 0.89–15.31 μg kg(−1). The developed method proved to be a specific and reliable tool for intensive monitoring of ZEN and ZEN-14G in complex feed matrices. Frontiers Media S.A. 2022-08-10 /pmc/articles/PMC9399508/ /pubmed/36034652 http://dx.doi.org/10.3389/fchem.2022.955266 Text en Copyright © 2022 Zhang, Cai, Fan, Huang, Zhao, Cao, Zhao, Tangni and Han. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Chemistry
Zhang, Zhiqi
Cai, Yaling
Fan, Kai
Huang, Qingwen
Zhao, Xiuying
Cao, Haojie
Zhao, Zhihui
Tangni, Emmanuel K.
Han, Zheng
Development of a reliable UHPLC-MS/MS method for simultaneous determination of zearalenone and zearalenone-14-glucoside in various feed products
title Development of a reliable UHPLC-MS/MS method for simultaneous determination of zearalenone and zearalenone-14-glucoside in various feed products
title_full Development of a reliable UHPLC-MS/MS method for simultaneous determination of zearalenone and zearalenone-14-glucoside in various feed products
title_fullStr Development of a reliable UHPLC-MS/MS method for simultaneous determination of zearalenone and zearalenone-14-glucoside in various feed products
title_full_unstemmed Development of a reliable UHPLC-MS/MS method for simultaneous determination of zearalenone and zearalenone-14-glucoside in various feed products
title_short Development of a reliable UHPLC-MS/MS method for simultaneous determination of zearalenone and zearalenone-14-glucoside in various feed products
title_sort development of a reliable uhplc-ms/ms method for simultaneous determination of zearalenone and zearalenone-14-glucoside in various feed products
topic Chemistry
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9399508/
https://www.ncbi.nlm.nih.gov/pubmed/36034652
http://dx.doi.org/10.3389/fchem.2022.955266
work_keys_str_mv AT zhangzhiqi developmentofareliableuhplcmsmsmethodforsimultaneousdeterminationofzearalenoneandzearalenone14glucosideinvariousfeedproducts
AT caiyaling developmentofareliableuhplcmsmsmethodforsimultaneousdeterminationofzearalenoneandzearalenone14glucosideinvariousfeedproducts
AT fankai developmentofareliableuhplcmsmsmethodforsimultaneousdeterminationofzearalenoneandzearalenone14glucosideinvariousfeedproducts
AT huangqingwen developmentofareliableuhplcmsmsmethodforsimultaneousdeterminationofzearalenoneandzearalenone14glucosideinvariousfeedproducts
AT zhaoxiuying developmentofareliableuhplcmsmsmethodforsimultaneousdeterminationofzearalenoneandzearalenone14glucosideinvariousfeedproducts
AT caohaojie developmentofareliableuhplcmsmsmethodforsimultaneousdeterminationofzearalenoneandzearalenone14glucosideinvariousfeedproducts
AT zhaozhihui developmentofareliableuhplcmsmsmethodforsimultaneousdeterminationofzearalenoneandzearalenone14glucosideinvariousfeedproducts
AT tangniemmanuelk developmentofareliableuhplcmsmsmethodforsimultaneousdeterminationofzearalenoneandzearalenone14glucosideinvariousfeedproducts
AT hanzheng developmentofareliableuhplcmsmsmethodforsimultaneousdeterminationofzearalenoneandzearalenone14glucosideinvariousfeedproducts