Cargando…

Preoperative Virtual Total Knee Arthroplasty Surgery Using a Computed Tomography-based 3-dimensional Model With Variation in Reference Points and Target Alignment to Predict Femoral Component Sizing

BACKGROUND: The purpose of this study was to investigate the size differences of 19 different femoral component placements from the standard position in total knee arthroplasty using 3-dimensional virtual surgery. METHODS: Three-dimensional bone models were reconstructed from the computed tomography...

Descripción completa

Detalles Bibliográficos
Autores principales: Ishibashi, Shojiro, Mizu-uchi, Hideki, Kawahara, Shinya, Tsushima, Hidetoshi, Akasaki, Yukio, Nakashima, Yasuharu
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9399891/
https://www.ncbi.nlm.nih.gov/pubmed/36032795
http://dx.doi.org/10.1016/j.artd.2022.07.008
_version_ 1784772629513633792
author Ishibashi, Shojiro
Mizu-uchi, Hideki
Kawahara, Shinya
Tsushima, Hidetoshi
Akasaki, Yukio
Nakashima, Yasuharu
author_facet Ishibashi, Shojiro
Mizu-uchi, Hideki
Kawahara, Shinya
Tsushima, Hidetoshi
Akasaki, Yukio
Nakashima, Yasuharu
author_sort Ishibashi, Shojiro
collection PubMed
description BACKGROUND: The purpose of this study was to investigate the size differences of 19 different femoral component placements from the standard position in total knee arthroplasty using 3-dimensional virtual surgery. METHODS: Three-dimensional bone models were reconstructed from the computed tomography data of 101 varus osteoarthritic knees. The distal femoral bone was cut perpendicular to the femoral mechanical axis (MA) in the coronal plane. Twenty different component placements consisting of 5 cutting directions (perpendicular to MA, 3° and 5° extension relative to MA [3°E-MA and 5°E-MA, respectively], and 3° and 5° flexion relative to MA [3°F-MA and 5°F-MA, respectively]) in the sagittal plane, 2 rotational alignments (clinical epicondylar axis [CEA] and surgical epicondylar axis [SEA]), and 2 rotational types of anterior reference guide (central [CR] and medial [MR]) were simulated. RESULTS: The mean anteroposterior dimension of femur ranged from 54.3 mm (5°F-MA, SEA, CR) to 62.5 mm (5°E-MA, CEA, MR). The largest and smallest differences of anteroposterior dimension from the standard position (3°F-MA, SEA, and CR) were 7.1 ± 1.3 mm (5°E-MA, CEA, and MR) and −1.2 ± 0.2 mm (5°F-MA, SEA, and CR), respectively. Multiple regression analysis revealed that flexion cutting direction, SEA, and CR were associated with smaller component size. CONCLUSIONS: The femoral component size can be affected easily by not only cutting direction but also the reference guide type and the target alignment. Our findings could provide surgeons with clinically useful information to fine-tune for unintended loose or tight joint gaps by adjusting the component size.
format Online
Article
Text
id pubmed-9399891
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-93998912022-08-25 Preoperative Virtual Total Knee Arthroplasty Surgery Using a Computed Tomography-based 3-dimensional Model With Variation in Reference Points and Target Alignment to Predict Femoral Component Sizing Ishibashi, Shojiro Mizu-uchi, Hideki Kawahara, Shinya Tsushima, Hidetoshi Akasaki, Yukio Nakashima, Yasuharu Arthroplast Today Original Research BACKGROUND: The purpose of this study was to investigate the size differences of 19 different femoral component placements from the standard position in total knee arthroplasty using 3-dimensional virtual surgery. METHODS: Three-dimensional bone models were reconstructed from the computed tomography data of 101 varus osteoarthritic knees. The distal femoral bone was cut perpendicular to the femoral mechanical axis (MA) in the coronal plane. Twenty different component placements consisting of 5 cutting directions (perpendicular to MA, 3° and 5° extension relative to MA [3°E-MA and 5°E-MA, respectively], and 3° and 5° flexion relative to MA [3°F-MA and 5°F-MA, respectively]) in the sagittal plane, 2 rotational alignments (clinical epicondylar axis [CEA] and surgical epicondylar axis [SEA]), and 2 rotational types of anterior reference guide (central [CR] and medial [MR]) were simulated. RESULTS: The mean anteroposterior dimension of femur ranged from 54.3 mm (5°F-MA, SEA, CR) to 62.5 mm (5°E-MA, CEA, MR). The largest and smallest differences of anteroposterior dimension from the standard position (3°F-MA, SEA, and CR) were 7.1 ± 1.3 mm (5°E-MA, CEA, and MR) and −1.2 ± 0.2 mm (5°F-MA, SEA, and CR), respectively. Multiple regression analysis revealed that flexion cutting direction, SEA, and CR were associated with smaller component size. CONCLUSIONS: The femoral component size can be affected easily by not only cutting direction but also the reference guide type and the target alignment. Our findings could provide surgeons with clinically useful information to fine-tune for unintended loose or tight joint gaps by adjusting the component size. Elsevier 2022-08-12 /pmc/articles/PMC9399891/ /pubmed/36032795 http://dx.doi.org/10.1016/j.artd.2022.07.008 Text en © 2022 Published by Elsevier Inc. on behalf of The American Association of Hip and Knee Surgeons. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Original Research
Ishibashi, Shojiro
Mizu-uchi, Hideki
Kawahara, Shinya
Tsushima, Hidetoshi
Akasaki, Yukio
Nakashima, Yasuharu
Preoperative Virtual Total Knee Arthroplasty Surgery Using a Computed Tomography-based 3-dimensional Model With Variation in Reference Points and Target Alignment to Predict Femoral Component Sizing
title Preoperative Virtual Total Knee Arthroplasty Surgery Using a Computed Tomography-based 3-dimensional Model With Variation in Reference Points and Target Alignment to Predict Femoral Component Sizing
title_full Preoperative Virtual Total Knee Arthroplasty Surgery Using a Computed Tomography-based 3-dimensional Model With Variation in Reference Points and Target Alignment to Predict Femoral Component Sizing
title_fullStr Preoperative Virtual Total Knee Arthroplasty Surgery Using a Computed Tomography-based 3-dimensional Model With Variation in Reference Points and Target Alignment to Predict Femoral Component Sizing
title_full_unstemmed Preoperative Virtual Total Knee Arthroplasty Surgery Using a Computed Tomography-based 3-dimensional Model With Variation in Reference Points and Target Alignment to Predict Femoral Component Sizing
title_short Preoperative Virtual Total Knee Arthroplasty Surgery Using a Computed Tomography-based 3-dimensional Model With Variation in Reference Points and Target Alignment to Predict Femoral Component Sizing
title_sort preoperative virtual total knee arthroplasty surgery using a computed tomography-based 3-dimensional model with variation in reference points and target alignment to predict femoral component sizing
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9399891/
https://www.ncbi.nlm.nih.gov/pubmed/36032795
http://dx.doi.org/10.1016/j.artd.2022.07.008
work_keys_str_mv AT ishibashishojiro preoperativevirtualtotalkneearthroplastysurgeryusingacomputedtomographybased3dimensionalmodelwithvariationinreferencepointsandtargetalignmenttopredictfemoralcomponentsizing
AT mizuuchihideki preoperativevirtualtotalkneearthroplastysurgeryusingacomputedtomographybased3dimensionalmodelwithvariationinreferencepointsandtargetalignmenttopredictfemoralcomponentsizing
AT kawaharashinya preoperativevirtualtotalkneearthroplastysurgeryusingacomputedtomographybased3dimensionalmodelwithvariationinreferencepointsandtargetalignmenttopredictfemoralcomponentsizing
AT tsushimahidetoshi preoperativevirtualtotalkneearthroplastysurgeryusingacomputedtomographybased3dimensionalmodelwithvariationinreferencepointsandtargetalignmenttopredictfemoralcomponentsizing
AT akasakiyukio preoperativevirtualtotalkneearthroplastysurgeryusingacomputedtomographybased3dimensionalmodelwithvariationinreferencepointsandtargetalignmenttopredictfemoralcomponentsizing
AT nakashimayasuharu preoperativevirtualtotalkneearthroplastysurgeryusingacomputedtomographybased3dimensionalmodelwithvariationinreferencepointsandtargetalignmenttopredictfemoralcomponentsizing