Cargando…
Clinical and radiographic outcomes of maxillary lateral incisors rehabilitation using Morse taper connection extra‐narrow implants at 12‐month follow‐up: A case report
Narrow‐diameter implants (≤3.5 mm) have been proposed to address the challenge of implant placement in cases of insufficient bone quantity, thin alveolar crest, and small cervical diameter teeth replacement The aim of this study is to report one‐year outcomes of extra‐narrow implant rehabilitation o...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9400033/ https://www.ncbi.nlm.nih.gov/pubmed/36034604 http://dx.doi.org/10.1002/ccr3.6248 |
_version_ | 1784772661925117952 |
---|---|
author | Thomé, Geninho Vianna, Camila Pereira Caldas, Waleska Bernardes, Sergio Rocha Uhlendorf, Jean Cartelli, Carolina Accorsi Trojan, Larissa Carvalho |
author_facet | Thomé, Geninho Vianna, Camila Pereira Caldas, Waleska Bernardes, Sergio Rocha Uhlendorf, Jean Cartelli, Carolina Accorsi Trojan, Larissa Carvalho |
author_sort | Thomé, Geninho |
collection | PubMed |
description | Narrow‐diameter implants (≤3.5 mm) have been proposed to address the challenge of implant placement in cases of insufficient bone quantity, thin alveolar crest, and small cervical diameter teeth replacement The aim of this study is to report one‐year outcomes of extra‐narrow implant rehabilitation of maxillary lateral incisors, due to agenesis, in a young adult that presented sites with reduced mesiodistal and buccolingual dimensions. A 26‐year‐old male patient in need of fixed‐implant supported prostheses due to the absence of permanent maxillary lateral incisors and with limited space, was submitted to surgery to receive two 2.9 mm hybrid Morse taper connection implants with hydrophilic surfaces. Immediate loading was applied by means of insertion of provisional prostheses, which were replaced for all‐ceramic prostheses 12 months after surgery. The 1 year follow‐up showed clinical and radiographic success of extra‐narrow implant rehabilitation. Also, both regions presented good evolution of peri‐implant esthetics, as assesses using the pink esthetic score, with improvements at 4 months follow‐up and reaching high scores 12 months after surgery. Although the prosthetic rehabilitation of maxillary lateral incisors is challenging due to limited space for the insertion of implants, the clinical case suggests that the use of extra‐narrow Morse Taper implants with hybrid design and hydrophilic surface is a reliable alternative, presenting good outcomes regarding hard and soft tissue and it is a versatile solution or immediate loading procedure. Further studies are needed to confirm extra‐narrow implant predictability. |
format | Online Article Text |
id | pubmed-9400033 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | John Wiley and Sons Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-94000332022-08-26 Clinical and radiographic outcomes of maxillary lateral incisors rehabilitation using Morse taper connection extra‐narrow implants at 12‐month follow‐up: A case report Thomé, Geninho Vianna, Camila Pereira Caldas, Waleska Bernardes, Sergio Rocha Uhlendorf, Jean Cartelli, Carolina Accorsi Trojan, Larissa Carvalho Clin Case Rep Case Report Narrow‐diameter implants (≤3.5 mm) have been proposed to address the challenge of implant placement in cases of insufficient bone quantity, thin alveolar crest, and small cervical diameter teeth replacement The aim of this study is to report one‐year outcomes of extra‐narrow implant rehabilitation of maxillary lateral incisors, due to agenesis, in a young adult that presented sites with reduced mesiodistal and buccolingual dimensions. A 26‐year‐old male patient in need of fixed‐implant supported prostheses due to the absence of permanent maxillary lateral incisors and with limited space, was submitted to surgery to receive two 2.9 mm hybrid Morse taper connection implants with hydrophilic surfaces. Immediate loading was applied by means of insertion of provisional prostheses, which were replaced for all‐ceramic prostheses 12 months after surgery. The 1 year follow‐up showed clinical and radiographic success of extra‐narrow implant rehabilitation. Also, both regions presented good evolution of peri‐implant esthetics, as assesses using the pink esthetic score, with improvements at 4 months follow‐up and reaching high scores 12 months after surgery. Although the prosthetic rehabilitation of maxillary lateral incisors is challenging due to limited space for the insertion of implants, the clinical case suggests that the use of extra‐narrow Morse Taper implants with hybrid design and hydrophilic surface is a reliable alternative, presenting good outcomes regarding hard and soft tissue and it is a versatile solution or immediate loading procedure. Further studies are needed to confirm extra‐narrow implant predictability. John Wiley and Sons Inc. 2022-08-24 /pmc/articles/PMC9400033/ /pubmed/36034604 http://dx.doi.org/10.1002/ccr3.6248 Text en © 2022 The Authors. Clinical Case Reports published by John Wiley & Sons Ltd. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by-nc-nd/4.0/ (https://creativecommons.org/licenses/by-nc-nd/4.0/) License, which permits use and distribution in any medium, provided the original work is properly cited, the use is non‐commercial and no modifications or adaptations are made. |
spellingShingle | Case Report Thomé, Geninho Vianna, Camila Pereira Caldas, Waleska Bernardes, Sergio Rocha Uhlendorf, Jean Cartelli, Carolina Accorsi Trojan, Larissa Carvalho Clinical and radiographic outcomes of maxillary lateral incisors rehabilitation using Morse taper connection extra‐narrow implants at 12‐month follow‐up: A case report |
title | Clinical and radiographic outcomes of maxillary lateral incisors rehabilitation using Morse taper connection extra‐narrow implants at 12‐month follow‐up: A case report |
title_full | Clinical and radiographic outcomes of maxillary lateral incisors rehabilitation using Morse taper connection extra‐narrow implants at 12‐month follow‐up: A case report |
title_fullStr | Clinical and radiographic outcomes of maxillary lateral incisors rehabilitation using Morse taper connection extra‐narrow implants at 12‐month follow‐up: A case report |
title_full_unstemmed | Clinical and radiographic outcomes of maxillary lateral incisors rehabilitation using Morse taper connection extra‐narrow implants at 12‐month follow‐up: A case report |
title_short | Clinical and radiographic outcomes of maxillary lateral incisors rehabilitation using Morse taper connection extra‐narrow implants at 12‐month follow‐up: A case report |
title_sort | clinical and radiographic outcomes of maxillary lateral incisors rehabilitation using morse taper connection extra‐narrow implants at 12‐month follow‐up: a case report |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9400033/ https://www.ncbi.nlm.nih.gov/pubmed/36034604 http://dx.doi.org/10.1002/ccr3.6248 |
work_keys_str_mv | AT thomegeninho clinicalandradiographicoutcomesofmaxillarylateralincisorsrehabilitationusingmorsetaperconnectionextranarrowimplantsat12monthfollowupacasereport AT viannacamilapereira clinicalandradiographicoutcomesofmaxillarylateralincisorsrehabilitationusingmorsetaperconnectionextranarrowimplantsat12monthfollowupacasereport AT caldaswaleska clinicalandradiographicoutcomesofmaxillarylateralincisorsrehabilitationusingmorsetaperconnectionextranarrowimplantsat12monthfollowupacasereport AT bernardessergiorocha clinicalandradiographicoutcomesofmaxillarylateralincisorsrehabilitationusingmorsetaperconnectionextranarrowimplantsat12monthfollowupacasereport AT uhlendorfjean clinicalandradiographicoutcomesofmaxillarylateralincisorsrehabilitationusingmorsetaperconnectionextranarrowimplantsat12monthfollowupacasereport AT cartellicarolinaaccorsi clinicalandradiographicoutcomesofmaxillarylateralincisorsrehabilitationusingmorsetaperconnectionextranarrowimplantsat12monthfollowupacasereport AT trojanlarissacarvalho clinicalandradiographicoutcomesofmaxillarylateralincisorsrehabilitationusingmorsetaperconnectionextranarrowimplantsat12monthfollowupacasereport |