Cargando…

Titanium Powder 3D-Printing Technology for a Novel Keratoprosthesis in Alkali-Burned Rabbits

PURPOSE: To evaluate the surgical technique, clinical performance, and biocompatibility of a novel keratoprosthesis (KPro) named KPro of Brazil (KoBra) in an alkali-burned rabbit model. METHODS: Two-piece three-dimensional-printed titanium powder and polymethyl methacrylate KPros were implanted into...

Descripción completa

Detalles Bibliográficos
Autores principales: Magalhães, Otavio de Azevedo, de Alcantara, Rafael Jorge Alves, Gomes, José Alvaro Pereira, Caiado de Castro Neto, Jarbas, Schor, Paulo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Association for Research in Vision and Ophthalmology 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9400124/
https://www.ncbi.nlm.nih.gov/pubmed/35976657
http://dx.doi.org/10.1167/tvst.11.8.14
_version_ 1784772680925315072
author Magalhães, Otavio de Azevedo
de Alcantara, Rafael Jorge Alves
Gomes, José Alvaro Pereira
Caiado de Castro Neto, Jarbas
Schor, Paulo
author_facet Magalhães, Otavio de Azevedo
de Alcantara, Rafael Jorge Alves
Gomes, José Alvaro Pereira
Caiado de Castro Neto, Jarbas
Schor, Paulo
author_sort Magalhães, Otavio de Azevedo
collection PubMed
description PURPOSE: To evaluate the surgical technique, clinical performance, and biocompatibility of a novel keratoprosthesis (KPro) named KPro of Brazil (KoBra) in an alkali-burned rabbit model. METHODS: Two-piece three-dimensional-printed titanium powder and polymethyl methacrylate KPros were implanted into 14 alkali-burned corneas of 14 rabbits using an autologous full-thickness corneal graft as the KPro carrier. Rabbits were examined weekly for 12 months to evaluate retention and postoperative complications. Anterior segment optical coherence tomography (AS-OCT) and scanning electron microscopy (SEM) were performed at the end of the experiment to evaluate the relationship between the KoBra and the carrier graft. RESULTS: All surgeries were performed without intraoperative complications, and the immediate postoperative period was uneventful. In 12 eyes (85.7%), the implanted KPros integrated into the operated eyes and maintained clear optics without extrusion or further complications over 12 months. Two eyes presented late postoperative complications that progressed to KPro extrusion: one had a presumed infectious keratitis, and the other had sterile stromal necrosis. AS-OCT demonstrated the correct relationship of the device and carrier graft in all remaining animals at the final follow-up. SEM findings indicate the integration of the porous structure of the back plate into the surrounding tissue. CONCLUSIONS: Clinical evaluations, AS-OCT, and SEM findings indicate good biointegr-ation of the implanted device into the corneal carrier graft. KoBra has the advantage of using recipients’ own corneas as the prosthesis supporter, and its surgical procedure is relatively simple and safe. TRANSLATIONAL RELEVANCE: Titanium three-dimensional-printed technology used in an animal limbal stem-cell deficiency model holds great promise for the treatment of corneal blindness in humans.
format Online
Article
Text
id pubmed-9400124
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher The Association for Research in Vision and Ophthalmology
record_format MEDLINE/PubMed
spelling pubmed-94001242022-08-25 Titanium Powder 3D-Printing Technology for a Novel Keratoprosthesis in Alkali-Burned Rabbits Magalhães, Otavio de Azevedo de Alcantara, Rafael Jorge Alves Gomes, José Alvaro Pereira Caiado de Castro Neto, Jarbas Schor, Paulo Transl Vis Sci Technol Cornea & External Disease PURPOSE: To evaluate the surgical technique, clinical performance, and biocompatibility of a novel keratoprosthesis (KPro) named KPro of Brazil (KoBra) in an alkali-burned rabbit model. METHODS: Two-piece three-dimensional-printed titanium powder and polymethyl methacrylate KPros were implanted into 14 alkali-burned corneas of 14 rabbits using an autologous full-thickness corneal graft as the KPro carrier. Rabbits were examined weekly for 12 months to evaluate retention and postoperative complications. Anterior segment optical coherence tomography (AS-OCT) and scanning electron microscopy (SEM) were performed at the end of the experiment to evaluate the relationship between the KoBra and the carrier graft. RESULTS: All surgeries were performed without intraoperative complications, and the immediate postoperative period was uneventful. In 12 eyes (85.7%), the implanted KPros integrated into the operated eyes and maintained clear optics without extrusion or further complications over 12 months. Two eyes presented late postoperative complications that progressed to KPro extrusion: one had a presumed infectious keratitis, and the other had sterile stromal necrosis. AS-OCT demonstrated the correct relationship of the device and carrier graft in all remaining animals at the final follow-up. SEM findings indicate the integration of the porous structure of the back plate into the surrounding tissue. CONCLUSIONS: Clinical evaluations, AS-OCT, and SEM findings indicate good biointegr-ation of the implanted device into the corneal carrier graft. KoBra has the advantage of using recipients’ own corneas as the prosthesis supporter, and its surgical procedure is relatively simple and safe. TRANSLATIONAL RELEVANCE: Titanium three-dimensional-printed technology used in an animal limbal stem-cell deficiency model holds great promise for the treatment of corneal blindness in humans. The Association for Research in Vision and Ophthalmology 2022-08-17 /pmc/articles/PMC9400124/ /pubmed/35976657 http://dx.doi.org/10.1167/tvst.11.8.14 Text en Copyright 2022 The Authors https://creativecommons.org/licenses/by-nc-nd/4.0/This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.
spellingShingle Cornea & External Disease
Magalhães, Otavio de Azevedo
de Alcantara, Rafael Jorge Alves
Gomes, José Alvaro Pereira
Caiado de Castro Neto, Jarbas
Schor, Paulo
Titanium Powder 3D-Printing Technology for a Novel Keratoprosthesis in Alkali-Burned Rabbits
title Titanium Powder 3D-Printing Technology for a Novel Keratoprosthesis in Alkali-Burned Rabbits
title_full Titanium Powder 3D-Printing Technology for a Novel Keratoprosthesis in Alkali-Burned Rabbits
title_fullStr Titanium Powder 3D-Printing Technology for a Novel Keratoprosthesis in Alkali-Burned Rabbits
title_full_unstemmed Titanium Powder 3D-Printing Technology for a Novel Keratoprosthesis in Alkali-Burned Rabbits
title_short Titanium Powder 3D-Printing Technology for a Novel Keratoprosthesis in Alkali-Burned Rabbits
title_sort titanium powder 3d-printing technology for a novel keratoprosthesis in alkali-burned rabbits
topic Cornea & External Disease
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9400124/
https://www.ncbi.nlm.nih.gov/pubmed/35976657
http://dx.doi.org/10.1167/tvst.11.8.14
work_keys_str_mv AT magalhaesotaviodeazevedo titaniumpowder3dprintingtechnologyforanovelkeratoprosthesisinalkaliburnedrabbits
AT dealcantararafaeljorgealves titaniumpowder3dprintingtechnologyforanovelkeratoprosthesisinalkaliburnedrabbits
AT gomesjosealvaropereira titaniumpowder3dprintingtechnologyforanovelkeratoprosthesisinalkaliburnedrabbits
AT caiadodecastronetojarbas titaniumpowder3dprintingtechnologyforanovelkeratoprosthesisinalkaliburnedrabbits
AT schorpaulo titaniumpowder3dprintingtechnologyforanovelkeratoprosthesisinalkaliburnedrabbits