Cargando…

Automated 3D Analysis of Clinical Magnetic Resonance Images Demonstrates Significant Reductions in Cam Morphology Following Arthroscopic Intervention in Contrast to Physiotherapy

PURPOSE: To obtain automated measurements of cam volume, surface area, and height from baseline (preintervention) and 12-month magnetic resonance (MR) images acquired from male and female patients allocated to physiotherapy (PT) or arthroscopic surgery (AS) management for femoroacetabular impingemen...

Descripción completa

Detalles Bibliográficos
Autores principales: Bugeja, Jessica M., Xia, Ying, Chandra, Shekhar S., Murphy, Nicholas J., Eyles, Jillian, Spiers, Libby, Crozier, Stuart, Hunter, David J., Fripp, Jurgen, Engstrom, Craig
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9402425/
https://www.ncbi.nlm.nih.gov/pubmed/36033193
http://dx.doi.org/10.1016/j.asmr.2022.04.020
_version_ 1784773173736112128
author Bugeja, Jessica M.
Xia, Ying
Chandra, Shekhar S.
Murphy, Nicholas J.
Eyles, Jillian
Spiers, Libby
Crozier, Stuart
Hunter, David J.
Fripp, Jurgen
Engstrom, Craig
author_facet Bugeja, Jessica M.
Xia, Ying
Chandra, Shekhar S.
Murphy, Nicholas J.
Eyles, Jillian
Spiers, Libby
Crozier, Stuart
Hunter, David J.
Fripp, Jurgen
Engstrom, Craig
author_sort Bugeja, Jessica M.
collection PubMed
description PURPOSE: To obtain automated measurements of cam volume, surface area, and height from baseline (preintervention) and 12-month magnetic resonance (MR) images acquired from male and female patients allocated to physiotherapy (PT) or arthroscopic surgery (AS) management for femoroacetabular impingement (FAI) in the Australian FASHIoN trial. METHODS: An automated segmentation pipeline (CamMorph) was used to obtain cam morphology data from three-dimensional (3D) MR hip examinations in FAI patients classified with mild, moderate, or major cam volumes. Pairwise comparisons between baseline and 12-month cam volume, surface area, and height data were performed within the PT and AS patient groups using paired t-tests or Wilcoxon signed-rank tests. RESULTS: A total of 43 patients were included with 15 PT patients (9 males, 6 females) and 28 AS patients (18 males, 10 females) for premanagement and postmanagement cam morphology assessments. Within the PT male and female patient groups, there were no significant differences between baseline and 12-month mean cam volume (male: 1269 vs 1288 mm(3), t[16] = −0.39; female: 545 vs 550 mm,(3)t[10] = −0.78), surface area (male: 1525 vs 1491 mm(2), t[16] = 0.92; female: 885 vs 925 mm,(2)t[10] = −0.78), maximum height (male: 4.36 vs 4.32 mm, t[16] = 0.34; female: 3.05 vs 2.96 mm, t[10] = 1.05) and average height (male: 2.18 vs 2.18 mm, t[16] = 0.22; female: 1.4 vs 1.43 mm, t[10] = −0.38). In contrast, within the AS male and female patient groups, there were significant differences between baseline and 12-month cam volume (male: 1343 vs 718 mm(3), W = 0.0; female: 499 vs 240 mm(3), t[18] = 2.89), surface area (male: 1520 vs 1031 mm(2), t(34) = 6.48; female: 782 vs 483 mm(2), t(18) = 3.02), maximum-height (male: 4.3 vs 3.42 mm, W = 13.5; female: 2.85 vs 2.24 mm, t(18) = 3.04) and average height (male: 2.17 vs 1.52 mm, W = 3.0; female: 1.4 vs 0.94 mm, W = 3.0). In AS patients, 3D bone models provided good visualization of cam bone mass removal postostectomy. CONCLUSIONS: Automated measurement of cam morphology from baseline (preintervention) and 12-month MR images demonstrated that the cam volume, surface area, maximum-height, and average height were significantly smaller in AS patients following ostectomy, whereas there were no significant differences in these cam measures in PT patients from the Australian FASHIoN study. LEVEL OF EVIDENCE: Level II, cohort study.
format Online
Article
Text
id pubmed-9402425
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-94024252022-08-26 Automated 3D Analysis of Clinical Magnetic Resonance Images Demonstrates Significant Reductions in Cam Morphology Following Arthroscopic Intervention in Contrast to Physiotherapy Bugeja, Jessica M. Xia, Ying Chandra, Shekhar S. Murphy, Nicholas J. Eyles, Jillian Spiers, Libby Crozier, Stuart Hunter, David J. Fripp, Jurgen Engstrom, Craig Arthrosc Sports Med Rehabil Original Article PURPOSE: To obtain automated measurements of cam volume, surface area, and height from baseline (preintervention) and 12-month magnetic resonance (MR) images acquired from male and female patients allocated to physiotherapy (PT) or arthroscopic surgery (AS) management for femoroacetabular impingement (FAI) in the Australian FASHIoN trial. METHODS: An automated segmentation pipeline (CamMorph) was used to obtain cam morphology data from three-dimensional (3D) MR hip examinations in FAI patients classified with mild, moderate, or major cam volumes. Pairwise comparisons between baseline and 12-month cam volume, surface area, and height data were performed within the PT and AS patient groups using paired t-tests or Wilcoxon signed-rank tests. RESULTS: A total of 43 patients were included with 15 PT patients (9 males, 6 females) and 28 AS patients (18 males, 10 females) for premanagement and postmanagement cam morphology assessments. Within the PT male and female patient groups, there were no significant differences between baseline and 12-month mean cam volume (male: 1269 vs 1288 mm(3), t[16] = −0.39; female: 545 vs 550 mm,(3)t[10] = −0.78), surface area (male: 1525 vs 1491 mm(2), t[16] = 0.92; female: 885 vs 925 mm,(2)t[10] = −0.78), maximum height (male: 4.36 vs 4.32 mm, t[16] = 0.34; female: 3.05 vs 2.96 mm, t[10] = 1.05) and average height (male: 2.18 vs 2.18 mm, t[16] = 0.22; female: 1.4 vs 1.43 mm, t[10] = −0.38). In contrast, within the AS male and female patient groups, there were significant differences between baseline and 12-month cam volume (male: 1343 vs 718 mm(3), W = 0.0; female: 499 vs 240 mm(3), t[18] = 2.89), surface area (male: 1520 vs 1031 mm(2), t(34) = 6.48; female: 782 vs 483 mm(2), t(18) = 3.02), maximum-height (male: 4.3 vs 3.42 mm, W = 13.5; female: 2.85 vs 2.24 mm, t(18) = 3.04) and average height (male: 2.17 vs 1.52 mm, W = 3.0; female: 1.4 vs 0.94 mm, W = 3.0). In AS patients, 3D bone models provided good visualization of cam bone mass removal postostectomy. CONCLUSIONS: Automated measurement of cam morphology from baseline (preintervention) and 12-month MR images demonstrated that the cam volume, surface area, maximum-height, and average height were significantly smaller in AS patients following ostectomy, whereas there were no significant differences in these cam measures in PT patients from the Australian FASHIoN study. LEVEL OF EVIDENCE: Level II, cohort study. Elsevier 2022-06-08 /pmc/articles/PMC9402425/ /pubmed/36033193 http://dx.doi.org/10.1016/j.asmr.2022.04.020 Text en © 2022 The Authors https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Original Article
Bugeja, Jessica M.
Xia, Ying
Chandra, Shekhar S.
Murphy, Nicholas J.
Eyles, Jillian
Spiers, Libby
Crozier, Stuart
Hunter, David J.
Fripp, Jurgen
Engstrom, Craig
Automated 3D Analysis of Clinical Magnetic Resonance Images Demonstrates Significant Reductions in Cam Morphology Following Arthroscopic Intervention in Contrast to Physiotherapy
title Automated 3D Analysis of Clinical Magnetic Resonance Images Demonstrates Significant Reductions in Cam Morphology Following Arthroscopic Intervention in Contrast to Physiotherapy
title_full Automated 3D Analysis of Clinical Magnetic Resonance Images Demonstrates Significant Reductions in Cam Morphology Following Arthroscopic Intervention in Contrast to Physiotherapy
title_fullStr Automated 3D Analysis of Clinical Magnetic Resonance Images Demonstrates Significant Reductions in Cam Morphology Following Arthroscopic Intervention in Contrast to Physiotherapy
title_full_unstemmed Automated 3D Analysis of Clinical Magnetic Resonance Images Demonstrates Significant Reductions in Cam Morphology Following Arthroscopic Intervention in Contrast to Physiotherapy
title_short Automated 3D Analysis of Clinical Magnetic Resonance Images Demonstrates Significant Reductions in Cam Morphology Following Arthroscopic Intervention in Contrast to Physiotherapy
title_sort automated 3d analysis of clinical magnetic resonance images demonstrates significant reductions in cam morphology following arthroscopic intervention in contrast to physiotherapy
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9402425/
https://www.ncbi.nlm.nih.gov/pubmed/36033193
http://dx.doi.org/10.1016/j.asmr.2022.04.020
work_keys_str_mv AT bugejajessicam automated3danalysisofclinicalmagneticresonanceimagesdemonstratessignificantreductionsincammorphologyfollowingarthroscopicinterventionincontrasttophysiotherapy
AT xiaying automated3danalysisofclinicalmagneticresonanceimagesdemonstratessignificantreductionsincammorphologyfollowingarthroscopicinterventionincontrasttophysiotherapy
AT chandrashekhars automated3danalysisofclinicalmagneticresonanceimagesdemonstratessignificantreductionsincammorphologyfollowingarthroscopicinterventionincontrasttophysiotherapy
AT murphynicholasj automated3danalysisofclinicalmagneticresonanceimagesdemonstratessignificantreductionsincammorphologyfollowingarthroscopicinterventionincontrasttophysiotherapy
AT eylesjillian automated3danalysisofclinicalmagneticresonanceimagesdemonstratessignificantreductionsincammorphologyfollowingarthroscopicinterventionincontrasttophysiotherapy
AT spierslibby automated3danalysisofclinicalmagneticresonanceimagesdemonstratessignificantreductionsincammorphologyfollowingarthroscopicinterventionincontrasttophysiotherapy
AT crozierstuart automated3danalysisofclinicalmagneticresonanceimagesdemonstratessignificantreductionsincammorphologyfollowingarthroscopicinterventionincontrasttophysiotherapy
AT hunterdavidj automated3danalysisofclinicalmagneticresonanceimagesdemonstratessignificantreductionsincammorphologyfollowingarthroscopicinterventionincontrasttophysiotherapy
AT frippjurgen automated3danalysisofclinicalmagneticresonanceimagesdemonstratessignificantreductionsincammorphologyfollowingarthroscopicinterventionincontrasttophysiotherapy
AT engstromcraig automated3danalysisofclinicalmagneticresonanceimagesdemonstratessignificantreductionsincammorphologyfollowingarthroscopicinterventionincontrasttophysiotherapy