The surgical management of glaucoma has been revolutionized by the introduction of minimally invasive glaucoma surgery (MIGS). The various MIGS options aim to meaningfully lower intraocular pressure with a better safety profile than traditional glaucoma surgery. The key clinical attributes and the e...

Descripción completa

Detalles Bibliográficos
Autores principales: Burgos-Blasco, Barbara, García-Feijóo, Julián, Perucho-Gonzalez, Lucia, Güemes-Villahoz, Noemi, Morales-Fernandez, Laura, Mendez-Hernández, Carmen D., Martinez de la Casa, Jose M., Konstas, Anastasios G.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Healthcare 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9402735/
https://www.ncbi.nlm.nih.gov/pubmed/35797002
http://dx.doi.org/10.1007/s12325-022-02230-1
_version_ 1784773224249163776
author Burgos-Blasco, Barbara
García-Feijóo, Julián
Perucho-Gonzalez, Lucia
Güemes-Villahoz, Noemi
Morales-Fernandez, Laura
Mendez-Hernández, Carmen D.
Martinez de la Casa, Jose M.
Konstas, Anastasios G.
author_facet Burgos-Blasco, Barbara
García-Feijóo, Julián
Perucho-Gonzalez, Lucia
Güemes-Villahoz, Noemi
Morales-Fernandez, Laura
Mendez-Hernández, Carmen D.
Martinez de la Casa, Jose M.
Konstas, Anastasios G.
author_sort Burgos-Blasco, Barbara
collection PubMed
description The surgical management of glaucoma has been revolutionized by the introduction of minimally invasive glaucoma surgery (MIGS). The various MIGS options aim to meaningfully lower intraocular pressure with a better safety profile than traditional glaucoma surgery. The key clinical attributes and the emerging potential of an ab externo MicroShunt (PreserFlo™) are reviewed in the context of published evidence and clinical experience. This novel MicroShunt consists of an 8.5-mm-long tube that is implanted in the eye via an ab externo approach enabling aqueous humor drainage into the sub-Tenon’s space through the formation of a bleb, similar in appearance to that created by trabeculectomy. The efficacy and safety of this procedure, the concomitant use of antimetabolites, the impact of tube positioning, and its future value in clinical practice are critically reviewed. Recent evidence has demonstrated the MicroShunt to be less effective than traditional filtration surgery, but with a significant improvement in safety. Cumulative data suggest that the new implant provides tangible clinical benefits to selected patients with glaucoma in need of further intraocular pressure (IOP) lowering. Future research should delineate the precise role of this and other MIGS options in the rapidly evolving glaucoma treatment algorithm.
format Online
Article
Text
id pubmed-9402735
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Springer Healthcare
record_format MEDLINE/PubMed
spelling pubmed-94027352022-08-26 Evaluation of a Novel Αb Εxterno MicroShunt for the Treatment of Glaucoma Burgos-Blasco, Barbara García-Feijóo, Julián Perucho-Gonzalez, Lucia Güemes-Villahoz, Noemi Morales-Fernandez, Laura Mendez-Hernández, Carmen D. Martinez de la Casa, Jose M. Konstas, Anastasios G. Adv Ther Review The surgical management of glaucoma has been revolutionized by the introduction of minimally invasive glaucoma surgery (MIGS). The various MIGS options aim to meaningfully lower intraocular pressure with a better safety profile than traditional glaucoma surgery. The key clinical attributes and the emerging potential of an ab externo MicroShunt (PreserFlo™) are reviewed in the context of published evidence and clinical experience. This novel MicroShunt consists of an 8.5-mm-long tube that is implanted in the eye via an ab externo approach enabling aqueous humor drainage into the sub-Tenon’s space through the formation of a bleb, similar in appearance to that created by trabeculectomy. The efficacy and safety of this procedure, the concomitant use of antimetabolites, the impact of tube positioning, and its future value in clinical practice are critically reviewed. Recent evidence has demonstrated the MicroShunt to be less effective than traditional filtration surgery, but with a significant improvement in safety. Cumulative data suggest that the new implant provides tangible clinical benefits to selected patients with glaucoma in need of further intraocular pressure (IOP) lowering. Future research should delineate the precise role of this and other MIGS options in the rapidly evolving glaucoma treatment algorithm. Springer Healthcare 2022-07-07 2022 /pmc/articles/PMC9402735/ /pubmed/35797002 http://dx.doi.org/10.1007/s12325-022-02230-1 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by-nc/4.0/Open AccessThis article is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License, which permits any non-commercial use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by-nc/4.0/ (https://creativecommons.org/licenses/by-nc/4.0/) .
spellingShingle Review
Burgos-Blasco, Barbara
García-Feijóo, Julián
Perucho-Gonzalez, Lucia
Güemes-Villahoz, Noemi
Morales-Fernandez, Laura
Mendez-Hernández, Carmen D.
Martinez de la Casa, Jose M.
Konstas, Anastasios G.
Evaluation of a Novel Αb Εxterno MicroShunt for the Treatment of Glaucoma
title Evaluation of a Novel Αb Εxterno MicroShunt for the Treatment of Glaucoma
title_full Evaluation of a Novel Αb Εxterno MicroShunt for the Treatment of Glaucoma
title_fullStr Evaluation of a Novel Αb Εxterno MicroShunt for the Treatment of Glaucoma
title_full_unstemmed Evaluation of a Novel Αb Εxterno MicroShunt for the Treatment of Glaucoma
title_short Evaluation of a Novel Αb Εxterno MicroShunt for the Treatment of Glaucoma
title_sort evaluation of a novel αb εxterno microshunt for the treatment of glaucoma
topic Review
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9402735/
https://www.ncbi.nlm.nih.gov/pubmed/35797002
http://dx.doi.org/10.1007/s12325-022-02230-1
work_keys_str_mv AT burgosblascobarbara evaluationofanovelabexternomicroshuntforthetreatmentofglaucoma
AT garciafeijoojulian evaluationofanovelabexternomicroshuntforthetreatmentofglaucoma
AT peruchogonzalezlucia evaluationofanovelabexternomicroshuntforthetreatmentofglaucoma
AT guemesvillahoznoemi evaluationofanovelabexternomicroshuntforthetreatmentofglaucoma
AT moralesfernandezlaura evaluationofanovelabexternomicroshuntforthetreatmentofglaucoma
AT mendezhernandezcarmend evaluationofanovelabexternomicroshuntforthetreatmentofglaucoma
AT martinezdelacasajosem evaluationofanovelabexternomicroshuntforthetreatmentofglaucoma
AT konstasanastasiosg evaluationofanovelabexternomicroshuntforthetreatmentofglaucoma