Cargando…

Safety of Cefazolin Test Dose in Patients With Penicillin Allergy Just Prior to Cardiac Device Implantation: A Single-Centre Experience

BACKGROUND: Cephalosporins are the cornerstone of cardiac device infection prophylaxis. Owing to fears of cross-reactivity, penicillin-allergic patients are exposed to potentially more-toxic drugs, with decreased efficacy. We evaluated the safety of a cefazolin test dose (CTD) in self-reported penic...

Descripción completa

Detalles Bibliográficos
Autores principales: Sarrazin, Jean-François, Laaouaj, Jamal, Philippon, François, Sanchez, Marina, Gervais, Philippe, Champagne, Jean, Steinberg, Christian, Nault, Isabelle, Roy, Karine, Plourde, Benoît, Blier, Louis, O’Hara, Gilles
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9402946/
https://www.ncbi.nlm.nih.gov/pubmed/36035731
http://dx.doi.org/10.1016/j.cjco.2022.04.007
Descripción
Sumario:BACKGROUND: Cephalosporins are the cornerstone of cardiac device infection prophylaxis. Owing to fears of cross-reactivity, penicillin-allergic patients are exposed to potentially more-toxic drugs, with decreased efficacy. We evaluated the safety of a cefazolin test dose (CTD) in self-reported penicillin-allergic patients. METHODS: In this single-centre study, we evaluated consecutive patients with chart documentation of penicillin allergy undergoing cardiac device implantation, over a 2-year period. A CTD was performed if no cephalosporin allergy or severe anaphylactic reaction to penicillin had been documented. Patients were given 2 doses of 100 mg IV cefazolin, and if no allergic reaction occurred after 5 minutes, the full dose (1800 mg) was administered in the electrophysiology laboratory just before the implantation procedure. RESULTS: A total of 2200 patients were included. The frequency of reported penicillin allergy was 9.3% (n = 204). In 80% of cases, the type of allergic reaction was not reported in medical notes or was unknown by the patient. A CTD was performed in 67.6% of patients with a penicillin allergy (n = 138). A total of 5 adverse events occurred (3.6% of patients [95% confidence interval, 1.1%-6.1%]) — 4 skin rashes and 1 tongue edema. These 5 patients became asymptomatic after antihistaminic and corticosteroid IV treatment. Even if the test dose was negative, 79% of patients also were administered vancomycin before the procedure, as it requires a 1-hour infusion prior to the CTD in the implantation procedure room. CONCLUSION: A CTD in most penicillin-allergic patients appears to be safe and allows its use per recommended guidelines.