Safety of Cefazolin Test Dose in Patients With Penicillin Allergy Just Prior to Cardiac Device Implantation: A Single-Centre Experience

BACKGROUND: Cephalosporins are the cornerstone of cardiac device infection prophylaxis. Owing to fears of cross-reactivity, penicillin-allergic patients are exposed to potentially more-toxic drugs, with decreased efficacy. We evaluated the safety of a cefazolin test dose (CTD) in self-reported penic...

Descripción completa

Detalles Bibliográficos
Autores principales: Sarrazin, Jean-François, Laaouaj, Jamal, Philippon, François, Sanchez, Marina, Gervais, Philippe, Champagne, Jean, Steinberg, Christian, Nault, Isabelle, Roy, Karine, Plourde, Benoît, Blier, Louis, O’Hara, Gilles
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9402946/
https://www.ncbi.nlm.nih.gov/pubmed/36035731
http://dx.doi.org/10.1016/j.cjco.2022.04.007
_version_ 1784773258061545472
author Sarrazin, Jean-François
Laaouaj, Jamal
Philippon, François
Sanchez, Marina
Gervais, Philippe
Champagne, Jean
Steinberg, Christian
Nault, Isabelle
Roy, Karine
Plourde, Benoît
Blier, Louis
O’Hara, Gilles
author_facet Sarrazin, Jean-François
Laaouaj, Jamal
Philippon, François
Sanchez, Marina
Gervais, Philippe
Champagne, Jean
Steinberg, Christian
Nault, Isabelle
Roy, Karine
Plourde, Benoît
Blier, Louis
O’Hara, Gilles
author_sort Sarrazin, Jean-François
collection PubMed
description BACKGROUND: Cephalosporins are the cornerstone of cardiac device infection prophylaxis. Owing to fears of cross-reactivity, penicillin-allergic patients are exposed to potentially more-toxic drugs, with decreased efficacy. We evaluated the safety of a cefazolin test dose (CTD) in self-reported penicillin-allergic patients. METHODS: In this single-centre study, we evaluated consecutive patients with chart documentation of penicillin allergy undergoing cardiac device implantation, over a 2-year period. A CTD was performed if no cephalosporin allergy or severe anaphylactic reaction to penicillin had been documented. Patients were given 2 doses of 100 mg IV cefazolin, and if no allergic reaction occurred after 5 minutes, the full dose (1800 mg) was administered in the electrophysiology laboratory just before the implantation procedure. RESULTS: A total of 2200 patients were included. The frequency of reported penicillin allergy was 9.3% (n = 204). In 80% of cases, the type of allergic reaction was not reported in medical notes or was unknown by the patient. A CTD was performed in 67.6% of patients with a penicillin allergy (n = 138). A total of 5 adverse events occurred (3.6% of patients [95% confidence interval, 1.1%-6.1%]) — 4 skin rashes and 1 tongue edema. These 5 patients became asymptomatic after antihistaminic and corticosteroid IV treatment. Even if the test dose was negative, 79% of patients also were administered vancomycin before the procedure, as it requires a 1-hour infusion prior to the CTD in the implantation procedure room. CONCLUSION: A CTD in most penicillin-allergic patients appears to be safe and allows its use per recommended guidelines.
format Online
Article
Text
id pubmed-9402946
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-94029462022-08-26 Safety of Cefazolin Test Dose in Patients With Penicillin Allergy Just Prior to Cardiac Device Implantation: A Single-Centre Experience Sarrazin, Jean-François Laaouaj, Jamal Philippon, François Sanchez, Marina Gervais, Philippe Champagne, Jean Steinberg, Christian Nault, Isabelle Roy, Karine Plourde, Benoît Blier, Louis O’Hara, Gilles CJC Open Original Article BACKGROUND: Cephalosporins are the cornerstone of cardiac device infection prophylaxis. Owing to fears of cross-reactivity, penicillin-allergic patients are exposed to potentially more-toxic drugs, with decreased efficacy. We evaluated the safety of a cefazolin test dose (CTD) in self-reported penicillin-allergic patients. METHODS: In this single-centre study, we evaluated consecutive patients with chart documentation of penicillin allergy undergoing cardiac device implantation, over a 2-year period. A CTD was performed if no cephalosporin allergy or severe anaphylactic reaction to penicillin had been documented. Patients were given 2 doses of 100 mg IV cefazolin, and if no allergic reaction occurred after 5 minutes, the full dose (1800 mg) was administered in the electrophysiology laboratory just before the implantation procedure. RESULTS: A total of 2200 patients were included. The frequency of reported penicillin allergy was 9.3% (n = 204). In 80% of cases, the type of allergic reaction was not reported in medical notes or was unknown by the patient. A CTD was performed in 67.6% of patients with a penicillin allergy (n = 138). A total of 5 adverse events occurred (3.6% of patients [95% confidence interval, 1.1%-6.1%]) — 4 skin rashes and 1 tongue edema. These 5 patients became asymptomatic after antihistaminic and corticosteroid IV treatment. Even if the test dose was negative, 79% of patients also were administered vancomycin before the procedure, as it requires a 1-hour infusion prior to the CTD in the implantation procedure room. CONCLUSION: A CTD in most penicillin-allergic patients appears to be safe and allows its use per recommended guidelines. Elsevier 2022-04-28 /pmc/articles/PMC9402946/ /pubmed/36035731 http://dx.doi.org/10.1016/j.cjco.2022.04.007 Text en © 2022 The Authors https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Original Article
Sarrazin, Jean-François
Laaouaj, Jamal
Philippon, François
Sanchez, Marina
Gervais, Philippe
Champagne, Jean
Steinberg, Christian
Nault, Isabelle
Roy, Karine
Plourde, Benoît
Blier, Louis
O’Hara, Gilles
Safety of Cefazolin Test Dose in Patients With Penicillin Allergy Just Prior to Cardiac Device Implantation: A Single-Centre Experience
title Safety of Cefazolin Test Dose in Patients With Penicillin Allergy Just Prior to Cardiac Device Implantation: A Single-Centre Experience
title_full Safety of Cefazolin Test Dose in Patients With Penicillin Allergy Just Prior to Cardiac Device Implantation: A Single-Centre Experience
title_fullStr Safety of Cefazolin Test Dose in Patients With Penicillin Allergy Just Prior to Cardiac Device Implantation: A Single-Centre Experience
title_full_unstemmed Safety of Cefazolin Test Dose in Patients With Penicillin Allergy Just Prior to Cardiac Device Implantation: A Single-Centre Experience
title_short Safety of Cefazolin Test Dose in Patients With Penicillin Allergy Just Prior to Cardiac Device Implantation: A Single-Centre Experience
title_sort safety of cefazolin test dose in patients with penicillin allergy just prior to cardiac device implantation: a single-centre experience
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9402946/
https://www.ncbi.nlm.nih.gov/pubmed/36035731
http://dx.doi.org/10.1016/j.cjco.2022.04.007
work_keys_str_mv AT sarrazinjeanfrancois safetyofcefazolintestdoseinpatientswithpenicillinallergyjustpriortocardiacdeviceimplantationasinglecentreexperience
AT laaouajjamal safetyofcefazolintestdoseinpatientswithpenicillinallergyjustpriortocardiacdeviceimplantationasinglecentreexperience
AT philipponfrancois safetyofcefazolintestdoseinpatientswithpenicillinallergyjustpriortocardiacdeviceimplantationasinglecentreexperience
AT sanchezmarina safetyofcefazolintestdoseinpatientswithpenicillinallergyjustpriortocardiacdeviceimplantationasinglecentreexperience
AT gervaisphilippe safetyofcefazolintestdoseinpatientswithpenicillinallergyjustpriortocardiacdeviceimplantationasinglecentreexperience
AT champagnejean safetyofcefazolintestdoseinpatientswithpenicillinallergyjustpriortocardiacdeviceimplantationasinglecentreexperience
AT steinbergchristian safetyofcefazolintestdoseinpatientswithpenicillinallergyjustpriortocardiacdeviceimplantationasinglecentreexperience
AT naultisabelle safetyofcefazolintestdoseinpatientswithpenicillinallergyjustpriortocardiacdeviceimplantationasinglecentreexperience
AT roykarine safetyofcefazolintestdoseinpatientswithpenicillinallergyjustpriortocardiacdeviceimplantationasinglecentreexperience
AT plourdebenoit safetyofcefazolintestdoseinpatientswithpenicillinallergyjustpriortocardiacdeviceimplantationasinglecentreexperience
AT blierlouis safetyofcefazolintestdoseinpatientswithpenicillinallergyjustpriortocardiacdeviceimplantationasinglecentreexperience
AT oharagilles safetyofcefazolintestdoseinpatientswithpenicillinallergyjustpriortocardiacdeviceimplantationasinglecentreexperience