Traumatic fracture of the polyethylene tibial post and cone in a posterior-stabilized total knee arthroplasty: A case report

INTRODUCTION AND IMPORTANCE: Very few reports addressed polyethylene tibial post and cone fractures requiring revision surgery. Up to our knowledge, this particular pattern of wear, involving 2 fracture areas simultaneously, has not been previously described. CASE PRESENTATION: A 70 year-old female...

Descripción completa

Detalles Bibliográficos
Autores principales: Alkheraiji, Abdulaziz, Borai, Sultana, Alfadhil, Rheema, AlJassir, Fawzi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9403208/
https://www.ncbi.nlm.nih.gov/pubmed/35901551
http://dx.doi.org/10.1016/j.ijscr.2022.107437
_version_ 1784773321614688256
author Alkheraiji, Abdulaziz
Borai, Sultana
Alfadhil, Rheema
AlJassir, Fawzi
author_facet Alkheraiji, Abdulaziz
Borai, Sultana
Alfadhil, Rheema
AlJassir, Fawzi
author_sort Alkheraiji, Abdulaziz
collection PubMed
description INTRODUCTION AND IMPORTANCE: Very few reports addressed polyethylene tibial post and cone fractures requiring revision surgery. Up to our knowledge, this particular pattern of wear, involving 2 fracture areas simultaneously, has not been previously described. CASE PRESENTATION: A 70 year-old female developed a fracture involving both the tibial insert post and cone after a minor trauma after undergoing posterior-stabilized total knee replacement 4 years prior. CLINICAL DISCUSSION: This unique pattern of wear may occur even after minor trauma. CONCLUSION: We recommend having a low threshold to investigate minor trauma in this patient population, even years after undergoing primary knee arthroplasty.
format Online
Article
Text
id pubmed-9403208
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-94032082022-08-26 Traumatic fracture of the polyethylene tibial post and cone in a posterior-stabilized total knee arthroplasty: A case report Alkheraiji, Abdulaziz Borai, Sultana Alfadhil, Rheema AlJassir, Fawzi Int J Surg Case Rep Case Report INTRODUCTION AND IMPORTANCE: Very few reports addressed polyethylene tibial post and cone fractures requiring revision surgery. Up to our knowledge, this particular pattern of wear, involving 2 fracture areas simultaneously, has not been previously described. CASE PRESENTATION: A 70 year-old female developed a fracture involving both the tibial insert post and cone after a minor trauma after undergoing posterior-stabilized total knee replacement 4 years prior. CLINICAL DISCUSSION: This unique pattern of wear may occur even after minor trauma. CONCLUSION: We recommend having a low threshold to investigate minor trauma in this patient population, even years after undergoing primary knee arthroplasty. Elsevier 2022-07-23 /pmc/articles/PMC9403208/ /pubmed/35901551 http://dx.doi.org/10.1016/j.ijscr.2022.107437 Text en © 2022 The Authors https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Case Report
Alkheraiji, Abdulaziz
Borai, Sultana
Alfadhil, Rheema
AlJassir, Fawzi
Traumatic fracture of the polyethylene tibial post and cone in a posterior-stabilized total knee arthroplasty: A case report
title Traumatic fracture of the polyethylene tibial post and cone in a posterior-stabilized total knee arthroplasty: A case report
title_full Traumatic fracture of the polyethylene tibial post and cone in a posterior-stabilized total knee arthroplasty: A case report
title_fullStr Traumatic fracture of the polyethylene tibial post and cone in a posterior-stabilized total knee arthroplasty: A case report
title_full_unstemmed Traumatic fracture of the polyethylene tibial post and cone in a posterior-stabilized total knee arthroplasty: A case report
title_short Traumatic fracture of the polyethylene tibial post and cone in a posterior-stabilized total knee arthroplasty: A case report
title_sort traumatic fracture of the polyethylene tibial post and cone in a posterior-stabilized total knee arthroplasty: a case report
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9403208/
https://www.ncbi.nlm.nih.gov/pubmed/35901551
http://dx.doi.org/10.1016/j.ijscr.2022.107437
work_keys_str_mv AT alkheraijiabdulaziz traumaticfractureofthepolyethylenetibialpostandconeinaposteriorstabilizedtotalkneearthroplastyacasereport
AT boraisultana traumaticfractureofthepolyethylenetibialpostandconeinaposteriorstabilizedtotalkneearthroplastyacasereport
AT alfadhilrheema traumaticfractureofthepolyethylenetibialpostandconeinaposteriorstabilizedtotalkneearthroplastyacasereport
AT aljassirfawzi traumaticfractureofthepolyethylenetibialpostandconeinaposteriorstabilizedtotalkneearthroplastyacasereport