Cargando…
Traumatic fracture of the polyethylene tibial post and cone in a posterior-stabilized total knee arthroplasty: A case report
INTRODUCTION AND IMPORTANCE: Very few reports addressed polyethylene tibial post and cone fractures requiring revision surgery. Up to our knowledge, this particular pattern of wear, involving 2 fracture areas simultaneously, has not been previously described. CASE PRESENTATION: A 70 year-old female...
Autores principales: | Alkheraiji, Abdulaziz, Borai, Sultana, Alfadhil, Rheema, AlJassir, Fawzi |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9403208/ https://www.ncbi.nlm.nih.gov/pubmed/35901551 http://dx.doi.org/10.1016/j.ijscr.2022.107437 |
Ejemplares similares
-
Extraarticular Pretibial Synovial Cyst After Arthroscopic Anterior Cruciate Ligament Reconstruction: A Case Report
por: Alfadhil, Rheema, et al.
Publicado: (2022) -
Bilateral trochlear avascular necrosis: A case report and brief review of the literature
por: Bakarman, Khalid, et al.
Publicado: (2021) -
Nontraumatic tibial polyethylene insert cone fracture in mobile-bearing posterior-stabilized total knee arthroplasty
por: Tanikake, Yohei, et al.
Publicado: (2016) -
INTRAOPERATIVE EVALUATION AND LEVEL OF CONTAMINATION DURING TOTAL KNEE ARTHROPLASTY
por: Alomar, Abdulaziz Z., et al.
Publicado: (2022) -
Nontraumatic Tibial Polyethylene Insert Cone Fracture in Rotating-Platform Total Knee Arthroplasty
por: Keogh, Cillian J., et al.
Publicado: (2021)