Cargando…

Effects of the Lubo cervical collar on airway patency in awake adults – A magnetic resonance imaging study

Introduction: Intended for use by prehospital first responders, the Lubo (TM) cervical collar is an adjustable, radiolucent, single-use device that incorporates a mechanical jaw thrust mechanism. The combination enables non-invasive airway management in cases of trauma where cervical motion restrict...

Descripción completa

Detalles Bibliográficos
Autores principales: Jaga, Rudhir, Behari, Dinell, Doubell, Anton P, Bergh, Kobus, Candy, Sally, Hofmeyr, Ross
Formato: Online Artículo Texto
Lenguaje:English
Publicado: African Federation for Emergency Medicine 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9403401/
https://www.ncbi.nlm.nih.gov/pubmed/36032784
http://dx.doi.org/10.1016/j.afjem.2022.07.008
_version_ 1784773367900930048
author Jaga, Rudhir
Behari, Dinell
Doubell, Anton P
Bergh, Kobus
Candy, Sally
Hofmeyr, Ross
author_facet Jaga, Rudhir
Behari, Dinell
Doubell, Anton P
Bergh, Kobus
Candy, Sally
Hofmeyr, Ross
author_sort Jaga, Rudhir
collection PubMed
description Introduction: Intended for use by prehospital first responders, the Lubo (TM) cervical collar is an adjustable, radiolucent, single-use device that incorporates a mechanical jaw thrust mechanism. The combination enables non-invasive airway management in cases of trauma where cervical motion restriction is necessary. The potential benefits include use as an airway adjuvant maintaining upper airway patency, reducing provider task loading. The limited research on the device efficacy and safety requires further investigation. Methods: A randomized, crossover, interventional study was performed to compare mean differences in airway patency at the level of the uvula, epiglottis, tongue and soft palate with and without the Lubo collar in awake volunteers using magnetic resonance imaging (MRI). Fourteen participants each underwent two MRI scans of the upper airway: A control scan with no Lubo collar, and an intervention scan with the Lubo collar applied and jaw thrust mechanism activated. Two independent radiologists measured anterior-posterior diameter of the airway at four anatomical levels on the resulting MRI images. Results: There was no significant difference in mean airway diameter between the control and intervention measurements at any level. Mean (SD; 95% CI: p-value) differences were 0.9 mm (-2.38; 2.3 to 0.5; p=0.17) at the epiglottis, 0.5 mm (1.6; -0.5 to 1.4; p=0.29) at the soft palate, 0.2 mm (2.86; -1.4 to 1.9; p = 0.78) at the tongue, 0.4 mm (4.04; -1.9 to 2.7; p = 0.72) at the uvula. Conclusion: The Lubo (TM) airway collar did not show a significant change in upper airway patency at four anatomical levels measured in awake adult participants. Further research is required to investigate its clinical use in patients that are unable to maintain upper airway tone. Groups of interest would include trauma, obstructive sleep apnoea, obesity and patients under general anaesthesia.
format Online
Article
Text
id pubmed-9403401
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher African Federation for Emergency Medicine
record_format MEDLINE/PubMed
spelling pubmed-94034012022-08-26 Effects of the Lubo cervical collar on airway patency in awake adults – A magnetic resonance imaging study Jaga, Rudhir Behari, Dinell Doubell, Anton P Bergh, Kobus Candy, Sally Hofmeyr, Ross Afr J Emerg Med Original Article Introduction: Intended for use by prehospital first responders, the Lubo (TM) cervical collar is an adjustable, radiolucent, single-use device that incorporates a mechanical jaw thrust mechanism. The combination enables non-invasive airway management in cases of trauma where cervical motion restriction is necessary. The potential benefits include use as an airway adjuvant maintaining upper airway patency, reducing provider task loading. The limited research on the device efficacy and safety requires further investigation. Methods: A randomized, crossover, interventional study was performed to compare mean differences in airway patency at the level of the uvula, epiglottis, tongue and soft palate with and without the Lubo collar in awake volunteers using magnetic resonance imaging (MRI). Fourteen participants each underwent two MRI scans of the upper airway: A control scan with no Lubo collar, and an intervention scan with the Lubo collar applied and jaw thrust mechanism activated. Two independent radiologists measured anterior-posterior diameter of the airway at four anatomical levels on the resulting MRI images. Results: There was no significant difference in mean airway diameter between the control and intervention measurements at any level. Mean (SD; 95% CI: p-value) differences were 0.9 mm (-2.38; 2.3 to 0.5; p=0.17) at the epiglottis, 0.5 mm (1.6; -0.5 to 1.4; p=0.29) at the soft palate, 0.2 mm (2.86; -1.4 to 1.9; p = 0.78) at the tongue, 0.4 mm (4.04; -1.9 to 2.7; p = 0.72) at the uvula. Conclusion: The Lubo (TM) airway collar did not show a significant change in upper airway patency at four anatomical levels measured in awake adult participants. Further research is required to investigate its clinical use in patients that are unable to maintain upper airway tone. Groups of interest would include trauma, obstructive sleep apnoea, obesity and patients under general anaesthesia. African Federation for Emergency Medicine 2022-12 2022-08-17 /pmc/articles/PMC9403401/ /pubmed/36032784 http://dx.doi.org/10.1016/j.afjem.2022.07.008 Text en © 2022 The Authors. Published by Elsevier B.V. on behalf of African Federation for Emergency Medicine. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Original Article
Jaga, Rudhir
Behari, Dinell
Doubell, Anton P
Bergh, Kobus
Candy, Sally
Hofmeyr, Ross
Effects of the Lubo cervical collar on airway patency in awake adults – A magnetic resonance imaging study
title Effects of the Lubo cervical collar on airway patency in awake adults – A magnetic resonance imaging study
title_full Effects of the Lubo cervical collar on airway patency in awake adults – A magnetic resonance imaging study
title_fullStr Effects of the Lubo cervical collar on airway patency in awake adults – A magnetic resonance imaging study
title_full_unstemmed Effects of the Lubo cervical collar on airway patency in awake adults – A magnetic resonance imaging study
title_short Effects of the Lubo cervical collar on airway patency in awake adults – A magnetic resonance imaging study
title_sort effects of the lubo cervical collar on airway patency in awake adults – a magnetic resonance imaging study
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9403401/
https://www.ncbi.nlm.nih.gov/pubmed/36032784
http://dx.doi.org/10.1016/j.afjem.2022.07.008
work_keys_str_mv AT jagarudhir effectsofthelubocervicalcollaronairwaypatencyinawakeadultsamagneticresonanceimagingstudy
AT beharidinell effectsofthelubocervicalcollaronairwaypatencyinawakeadultsamagneticresonanceimagingstudy
AT doubellantonp effectsofthelubocervicalcollaronairwaypatencyinawakeadultsamagneticresonanceimagingstudy
AT berghkobus effectsofthelubocervicalcollaronairwaypatencyinawakeadultsamagneticresonanceimagingstudy
AT candysally effectsofthelubocervicalcollaronairwaypatencyinawakeadultsamagneticresonanceimagingstudy
AT hofmeyrross effectsofthelubocervicalcollaronairwaypatencyinawakeadultsamagneticresonanceimagingstudy