Cargando…
Ferumoxytol-enhanced 4D multiphase, steady-state imaging with magnetic resonance in congenital heart disease: ventricular volume and function across 2D and 3D software platforms
BACKGROUND: Quantitative ventricular volumetry and function are important in the management of congenital heart disease (CHD). Ferumoxytol-enhanced (FE) 4D multiphase, steady state imaging with contrast enhancement (MUSIC) enables high-resolution, 3D cardiac phase-resolved magnetic resonance imaging...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
AME Publishing Company
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9403575/ https://www.ncbi.nlm.nih.gov/pubmed/36060580 http://dx.doi.org/10.21037/qims-21-1243 |
_version_ | 1784773407797149696 |
---|---|
author | Yoshida, Takegawa Chen, Joseph J. Zhou, Bill Finn, J. Paul Hu, Peng Nguyen, Kim-Lien |
author_facet | Yoshida, Takegawa Chen, Joseph J. Zhou, Bill Finn, J. Paul Hu, Peng Nguyen, Kim-Lien |
author_sort | Yoshida, Takegawa |
collection | PubMed |
description | BACKGROUND: Quantitative ventricular volumetry and function are important in the management of congenital heart disease (CHD). Ferumoxytol-enhanced (FE) 4D multiphase, steady state imaging with contrast enhancement (MUSIC) enables high-resolution, 3D cardiac phase-resolved magnetic resonance imaging (MRI) of the beating heart and extracardiac vessels in a single acquisition and without concerns about renal impairment. We aim to evaluate the semi-automatic quantification of ventricular volumetry and function of 4D MUSIC MRI using 2D and 3D software platforms. METHODS: This HIPAA-compliant and IRB-approved study prospectively recruited 50 children with CHD (3 days to 18 years) who underwent 4D MUSIC MRI at 3.0T between 2013–2017 for clinical indications. Each patient was either intubated in the neonatal intensive care unit (NICU) or underwent general anesthesia at MRI suite. For 2D analysis, we reformatted MUSIC images in Digital Imaging and Communications in Medicine (DICOM) format into ventricular short-axis slices with zero interslice gap. For 3D analysis, we imported DICOMs into a commercially available 3D software platform. Using semi-automatic thresholding, we quantified biventricular volume and ejection fraction (EF). We assessed the bias between MUSIC-derived 2D vs. 3D measurements and correlation between MUSIC vs. conventional 2D balanced steady-state free precession (bSSFP) cine images. We evaluated intra- and inter-observer agreement. RESULTS: There was a high degree of correlation between MUSIC-derived volumetric and functional measurements using 2D vs. 3D software (r=0.99, P<0.001). Volumes derived using 3D software platforms were larger than 2D by 0.2 to 2.0 mL/m(2) whereas EF measurements were higher by 1.2–3.0%. MUSIC volumetric and functional measures derived from 2D and 3D software platforms corresponded highly with those derived from multi-slice SSFP cine images (r=0.99, P<0.001). The mean difference in volume for reformatted 4D MUSIC relative to bSSFP cine was 1.5 to 3.9 mL/m(2). Intra- and inter-observer reliability was excellent. CONCLUSIONS: Accurate and reliable ventricular volumetry and function can be derived from FE 4D MUSIC MRI studies using commercially available 2D and 3D software platforms. If fully validated in multicenter studies, the FE 4D-MUSIC pulse sequence may supercede conventional multislice 2D cine cardiovascular MRI acquisition protocols for functional evaluation of children with complex CHD. |
format | Online Article Text |
id | pubmed-9403575 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | AME Publishing Company |
record_format | MEDLINE/PubMed |
spelling | pubmed-94035752022-09-01 Ferumoxytol-enhanced 4D multiphase, steady-state imaging with magnetic resonance in congenital heart disease: ventricular volume and function across 2D and 3D software platforms Yoshida, Takegawa Chen, Joseph J. Zhou, Bill Finn, J. Paul Hu, Peng Nguyen, Kim-Lien Quant Imaging Med Surg Original Article BACKGROUND: Quantitative ventricular volumetry and function are important in the management of congenital heart disease (CHD). Ferumoxytol-enhanced (FE) 4D multiphase, steady state imaging with contrast enhancement (MUSIC) enables high-resolution, 3D cardiac phase-resolved magnetic resonance imaging (MRI) of the beating heart and extracardiac vessels in a single acquisition and without concerns about renal impairment. We aim to evaluate the semi-automatic quantification of ventricular volumetry and function of 4D MUSIC MRI using 2D and 3D software platforms. METHODS: This HIPAA-compliant and IRB-approved study prospectively recruited 50 children with CHD (3 days to 18 years) who underwent 4D MUSIC MRI at 3.0T between 2013–2017 for clinical indications. Each patient was either intubated in the neonatal intensive care unit (NICU) or underwent general anesthesia at MRI suite. For 2D analysis, we reformatted MUSIC images in Digital Imaging and Communications in Medicine (DICOM) format into ventricular short-axis slices with zero interslice gap. For 3D analysis, we imported DICOMs into a commercially available 3D software platform. Using semi-automatic thresholding, we quantified biventricular volume and ejection fraction (EF). We assessed the bias between MUSIC-derived 2D vs. 3D measurements and correlation between MUSIC vs. conventional 2D balanced steady-state free precession (bSSFP) cine images. We evaluated intra- and inter-observer agreement. RESULTS: There was a high degree of correlation between MUSIC-derived volumetric and functional measurements using 2D vs. 3D software (r=0.99, P<0.001). Volumes derived using 3D software platforms were larger than 2D by 0.2 to 2.0 mL/m(2) whereas EF measurements were higher by 1.2–3.0%. MUSIC volumetric and functional measures derived from 2D and 3D software platforms corresponded highly with those derived from multi-slice SSFP cine images (r=0.99, P<0.001). The mean difference in volume for reformatted 4D MUSIC relative to bSSFP cine was 1.5 to 3.9 mL/m(2). Intra- and inter-observer reliability was excellent. CONCLUSIONS: Accurate and reliable ventricular volumetry and function can be derived from FE 4D MUSIC MRI studies using commercially available 2D and 3D software platforms. If fully validated in multicenter studies, the FE 4D-MUSIC pulse sequence may supercede conventional multislice 2D cine cardiovascular MRI acquisition protocols for functional evaluation of children with complex CHD. AME Publishing Company 2022-09 /pmc/articles/PMC9403575/ /pubmed/36060580 http://dx.doi.org/10.21037/qims-21-1243 Text en 2022 Quantitative Imaging in Medicine and Surgery. All rights reserved. https://creativecommons.org/licenses/by-nc-nd/4.0/Open Access Statement: This is an Open Access article distributed in accordance with the Creative Commons Attribution-NonCommercial-NoDerivs 4.0 International License (CC BY-NC-ND 4.0), which permits the non-commercial replication and distribution of the article with the strict proviso that no changes or edits are made and the original work is properly cited (including links to both the formal publication through the relevant DOI and the license). See: https://creativecommons.org/licenses/by-nc-nd/4.0 (https://creativecommons.org/licenses/by-nc-nd/4.0/) . |
spellingShingle | Original Article Yoshida, Takegawa Chen, Joseph J. Zhou, Bill Finn, J. Paul Hu, Peng Nguyen, Kim-Lien Ferumoxytol-enhanced 4D multiphase, steady-state imaging with magnetic resonance in congenital heart disease: ventricular volume and function across 2D and 3D software platforms |
title | Ferumoxytol-enhanced 4D multiphase, steady-state imaging with magnetic resonance in congenital heart disease: ventricular volume and function across 2D and 3D software platforms |
title_full | Ferumoxytol-enhanced 4D multiphase, steady-state imaging with magnetic resonance in congenital heart disease: ventricular volume and function across 2D and 3D software platforms |
title_fullStr | Ferumoxytol-enhanced 4D multiphase, steady-state imaging with magnetic resonance in congenital heart disease: ventricular volume and function across 2D and 3D software platforms |
title_full_unstemmed | Ferumoxytol-enhanced 4D multiphase, steady-state imaging with magnetic resonance in congenital heart disease: ventricular volume and function across 2D and 3D software platforms |
title_short | Ferumoxytol-enhanced 4D multiphase, steady-state imaging with magnetic resonance in congenital heart disease: ventricular volume and function across 2D and 3D software platforms |
title_sort | ferumoxytol-enhanced 4d multiphase, steady-state imaging with magnetic resonance in congenital heart disease: ventricular volume and function across 2d and 3d software platforms |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9403575/ https://www.ncbi.nlm.nih.gov/pubmed/36060580 http://dx.doi.org/10.21037/qims-21-1243 |
work_keys_str_mv | AT yoshidatakegawa ferumoxytolenhanced4dmultiphasesteadystateimagingwithmagneticresonanceincongenitalheartdiseaseventricularvolumeandfunctionacross2dand3dsoftwareplatforms AT chenjosephj ferumoxytolenhanced4dmultiphasesteadystateimagingwithmagneticresonanceincongenitalheartdiseaseventricularvolumeandfunctionacross2dand3dsoftwareplatforms AT zhoubill ferumoxytolenhanced4dmultiphasesteadystateimagingwithmagneticresonanceincongenitalheartdiseaseventricularvolumeandfunctionacross2dand3dsoftwareplatforms AT finnjpaul ferumoxytolenhanced4dmultiphasesteadystateimagingwithmagneticresonanceincongenitalheartdiseaseventricularvolumeandfunctionacross2dand3dsoftwareplatforms AT hupeng ferumoxytolenhanced4dmultiphasesteadystateimagingwithmagneticresonanceincongenitalheartdiseaseventricularvolumeandfunctionacross2dand3dsoftwareplatforms AT nguyenkimlien ferumoxytolenhanced4dmultiphasesteadystateimagingwithmagneticresonanceincongenitalheartdiseaseventricularvolumeandfunctionacross2dand3dsoftwareplatforms |